These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

148 related articles for article (PubMed ID: 33550307)

  • 1. Evaluation of Axial Length Measurement Using Enhanced Retina Visualization Mode of the Swept-Source Optical Coherence Tomography Biometer in Dense Cataract.
    Tamaoki A; Kojima T; Hasegawa A; Yamamoto M; Kaga T; Tanaka K; Ichikawa K
    Ophthalmic Res; 2021; 64(4):595-603. PubMed ID: 33550307
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Clinical Evaluation of a New Swept-Source Optical Coherence Biometer That Uses Individual Refractive Indices to Measure Axial Length in Cataract Patients.
    Tamaoki A; Kojima T; Hasegawa A; Yamamoto M; Kaga T; Tanaka K; Ichikawa K
    Ophthalmic Res; 2019; 62(1):11-23. PubMed ID: 30889604
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comprehensive Comparison of Axial Length Measurement With Three Swept-Source OCT-Based Biometers and Partial Coherence Interferometry.
    Huang J; Chen H; Li Y; Chen Z; Gao R; Yu J; Zhao Y; Lu W; McAlinden C; Wang Q
    J Refract Surg; 2019 Feb; 35(2):115-120. PubMed ID: 30742226
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Axial Length Measurement Failure Rates With Biometers Using Swept-Source Optical Coherence Tomography Compared to Partial-Coherence Interferometry and Optical Low-Coherence Interferometry.
    McAlinden C; Wang Q; Gao R; Zhao W; Yu A; Li Y; Guo Y; Huang J
    Am J Ophthalmol; 2017 Jan; 173():64-69. PubMed ID: 27664702
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Accuracy of swept-source optical coherence tomography based biometry for intraocular lens power calculation: a retrospective cross-sectional study.
    An Y; Kang EK; Kim H; Kang MJ; Byun YS; Joo CK
    BMC Ophthalmol; 2019 Jan; 19(1):30. PubMed ID: 30678658
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Clinical comparison of a new swept-source optical coherence tomography-based optical biometer and a time-domain optical coherence tomography-based optical biometer.
    Srivannaboon S; Chirapapaisan C; Chonpimai P; Loket S
    J Cataract Refract Surg; 2015 Oct; 41(10):2224-32. PubMed ID: 26703299
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Ocular biometry in dense cataracts: Comparison of partial-coherence interferometry, swept-source optical coherence tomography and immersion ultrasound.
    González-Godínez S; Saucedo-Urdapilleta R; Mayorquín-Ruiz M; Velasco-Barona C; Moragrega-Adame E; Domínguez-Varela IA; Gonzalez-Salinas R
    Indian J Ophthalmol; 2022 Jan; 70(1):107-111. PubMed ID: 34937218
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Efficiency and measurements agreement between swept-source OCT and low-coherence interferometry biometry systems.
    Calvo-Sanz JA; Portero-Benito A; Arias-Puente A
    Graefes Arch Clin Exp Ophthalmol; 2018 Mar; 256(3):559-566. PubMed ID: 29392397
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Efficacy of Swept-source Optical Coherence Tomography in Axial Length Measurement for Advanced Cataract Patients.
    Chirapapaisan C; Srivannaboon S; Chonpimai P
    Optom Vis Sci; 2020 Mar; 97(3):186-191. PubMed ID: 32168241
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Repeatability and Agreement of a Swept-Source Optical Coherence Tomography-Based Biometer IOLMaster 700 Versus a Scheimpflug Imaging-Based Biometer AL-Scan in Cataract Patients.
    Chan TCY; Wan KH; Tang FY; Wang YM; Yu M; Cheung C
    Eye Contact Lens; 2020 Jan; 46(1):35-45. PubMed ID: 30985487
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Reproducibility of a long-range swept-source optical coherence tomography ocular biometry system and comparison with clinical biometers.
    Grulkowski I; Liu JJ; Zhang JY; Potsaid B; Jayaraman V; Cable AE; Duker JS; Fujimoto JG
    Ophthalmology; 2013 Nov; 120(11):2184-90. PubMed ID: 23755873
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Biometry measurements using a new large-coherence-length swept-source optical coherence tomographer.
    Shammas HJ; Ortiz S; Shammas MC; Kim SH; Chong C
    J Cataract Refract Surg; 2016 Jan; 42(1):50-61. PubMed ID: 26948778
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Axial length measurements: Comparison of a new swept-source optical coherence tomography-based biometer and partial coherence interferometry in myopia.
    Yang JY; Kim HK; Kim SS
    J Cataract Refract Surg; 2017 Mar; 43(3):328-332. PubMed ID: 28410713
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Biometry with a new swept-source optical coherence tomography biometer: Repeatability and agreement with an optical low-coherence reflectometry device.
    Kurian M; Negalur N; Das S; Puttaiah NK; Haria D; J TS; Thakkar MM
    J Cataract Refract Surg; 2016 Apr; 42(4):577-81. PubMed ID: 27113881
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of two swept-source optical coherence tomography biometers and a partial coherence interferometer.
    Yang CM; Lim DH; Kim HJ; Chung TY
    PLoS One; 2019; 14(10):e0223114. PubMed ID: 31603903
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Axial length measurement and detection rates using a swept-source optical coherence tomography-based biometer in the presence of a dense vitreous hemorrhage.
    Wang Q; Huang Y; Gao R; Chen H; Song B; Tu R; Zhao Y; McAlinden C; Huang J
    J Cataract Refract Surg; 2020 Mar; 46(3):360-364. PubMed ID: 32050216
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Accuracy of a New Swept-Source Optical Coherence Tomography Biometer for IOL Power Calculation and Comparison to IOLMaster.
    Savini G; Hoffer KJ; Shammas HJ; Aramberri J; Huang J; Barboni P
    J Refract Surg; 2017 Oct; 33(10):690-695. PubMed ID: 28991337
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of a new optical biometer using swept-source optical coherence tomography and a biometer using optical low-coherence reflectometry.
    Hoffer KJ; Hoffmann PC; Savini G
    J Cataract Refract Surg; 2016 Aug; 42(8):1165-72. PubMed ID: 27531293
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Assessing the Validity of Measurements of Swept-source and Partial Coherence Interferometry Devices in Cataract Patients.
    Ghaffari R; Mahmoudzadeh R; Mohammadi SS; Salabati M; Latifi G; Ghassemi H
    Optom Vis Sci; 2019 Oct; 96(10):745-750. PubMed ID: 31592957
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparative analysis of 2 swept-source optical coherence tomography biometers.
    Sabatino F; Matarazzo F; Findl O; Maurino V
    J Cataract Refract Surg; 2019 Aug; 45(8):1124-1129. PubMed ID: 31174987
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.