316 related articles for article (PubMed ID: 33550932)
1. Treatment of displaced fractures of the patella: Tension band wiring technique with the one-end or both-ends K-wire bending fixation method.
Huang PH; Hsu CH; Hsu SL; Liu HC
J Orthop Surg (Hong Kong); 2021; 29(1):2309499020988179. PubMed ID: 33550932
[TBL] [Abstract][Full Text] [Related]
2. Patella fracture fixation with suture and wire: you reap what you sew.
Egol K; Howard D; Monroy A; Crespo A; Tejwani N; Davidovitch R
Iowa Orthop J; 2014; 34():63-7. PubMed ID: 25328461
[TBL] [Abstract][Full Text] [Related]
3. Treatment of displaced transverse fractures of the patella: modified tension band wiring technique with or without augmented circumferential cerclage wire fixation.
Yang TY; Huang TW; Chuang PY; Huang KC
BMC Musculoskelet Disord; 2018 May; 19(1):167. PubMed ID: 29793461
[TBL] [Abstract][Full Text] [Related]
4. Comparison of the outcomes of cannulated screws vs. modified tension band wiring fixation techniques in the management of mildly displaced patellar fractures.
Lin T; Liu J; Xiao B; Fu D; Yang S
BMC Musculoskelet Disord; 2015 Oct; 16():282. PubMed ID: 26445425
[TBL] [Abstract][Full Text] [Related]
5. Factors affecting the outcomes of modified tension band wiring techniques in transverse patellar fractures.
Hsu KL; Chang WL; Yang CY; Yeh ML; Chang CW
Injury; 2017 Dec; 48(12):2800-2806. PubMed ID: 29037518
[TBL] [Abstract][Full Text] [Related]
6. [Separate vertical wiring combined with tension band and Kirschner-wire plus cerclage wire in the treatment of displaced inferior pole fractures of the patella].
Zhang J; Jiang XY; Huang XW
Beijing Da Xue Xue Bao Yi Xue Ban; 2016 Jun; 48(3):534-8. PubMed ID: 27318920
[TBL] [Abstract][Full Text] [Related]
7. Comparison of the Therapeutic Effects of Tension Band with Cannulated Screw and Tension Band with Kirschner Wire on Patella Fracture.
Liu C; Ren H; Wan C; Ma J
Comput Math Methods Med; 2020; 2020():4065978. PubMed ID: 32908578
[TBL] [Abstract][Full Text] [Related]
8. Biomechanical evaluation of the tension band wiring principle. A comparison between two different techniques for transverse patella fracture fixation.
Zderic I; Stoffel K; Sommer C; Höntzsch D; Gueorguiev B
Injury; 2017 Aug; 48(8):1749-1757. PubMed ID: 28622833
[TBL] [Abstract][Full Text] [Related]
9. Horizontal versus vertical orientation of the loop for tension band wiring of transverse patella fractures.
Lee SK; Hwang YS; Choy WS
Orthopedics; 2014 Mar; 37(3):e265-71. PubMed ID: 24762154
[TBL] [Abstract][Full Text] [Related]
10. Patellar tension band wiring: a revised technique.
Wu CC; Tai CL; Chen WJ
Arch Orthop Trauma Surg; 2001; 121(1-2):12-6. PubMed ID: 11195111
[TBL] [Abstract][Full Text] [Related]
11. Study on the therapeutic effect of Kirschner wire tension band combined with anchor cross-stitch technique in the treatment of comminuted patellar inferopolar fractures.
Duan S; Zhang H; Liang H; Xu R; Sun M; Liu H; Zhou X; Wen H; Cai Z
PLoS One; 2024; 19(5):e0302839. PubMed ID: 38696506
[TBL] [Abstract][Full Text] [Related]
12. Delayed migration of K-wire into popliteal fossa used for tension band wiring of patellar fracture.
Meena S; Nag HL; Kumar S; Barwar N; Mittal S; Singla A
Chin J Traumatol; 2013; 16(3):186-8. PubMed ID: 23735556
[TBL] [Abstract][Full Text] [Related]
13. Complications Related to Implant Fixation of Patellar Fractures: Comparison of Ring Pins versus Bent K-Wires.
Kyung MG; Lee SH; Kim MB
J Knee Surg; 2017 Jul; 30(6):560-564. PubMed ID: 27776370
[TBL] [Abstract][Full Text] [Related]
14. Hook plating in patella fractures.
Jang JH; Rhee SJ; Kim JW
Injury; 2019 Nov; 50(11):2084-2088. PubMed ID: 31445832
[TBL] [Abstract][Full Text] [Related]
15. A Biomechanical Study of an Alternative Internal Fixation Method for Transverse Patella Fractures.
Han S; Li D; Zhang P; Yin X; Kou Y; Han N; Fu Z
Orthopedics; 2018 Sep; 41(5):e643-e648. PubMed ID: 30011055
[TBL] [Abstract][Full Text] [Related]
16. Anchor and Krackow-"8" Suture for the Fixation of Distal Pole Fractures of the Patella: Comparison to Kirschner Wire.
Xie J; Fu Y; Li J; Yu H; Zhang Y; Jing J
Orthop Surg; 2022 Feb; 14(2):374-382. PubMed ID: 34964263
[TBL] [Abstract][Full Text] [Related]
17. Migration of a Kirschner wire to the dorsolateral side of the foot following osteosynthesis of a patella fracture with tension band wiring: a case report.
Aydın E; Dülgeroğlu TC; Metineren H
J Med Case Rep; 2016 Feb; 10():41. PubMed ID: 26911242
[TBL] [Abstract][Full Text] [Related]
18. Where should Kirschner wires be placed when fixing patella fracture with modified tension-band wiring? A finite element analysis.
Ling M; Zhan S; Jiang D; Hu H; Zhang C
J Orthop Surg Res; 2019 Jan; 14(1):14. PubMed ID: 30634995
[TBL] [Abstract][Full Text] [Related]
19. Complications following tension-band fixation of patellar fractures with cannulated screws compared with Kirschner wires.
Hoshino CM; Tran W; Tiberi JV; Black MH; Li BH; Gold SM; Navarro RA
J Bone Joint Surg Am; 2013 Apr; 95(7):653-9. PubMed ID: 23553301
[TBL] [Abstract][Full Text] [Related]
20. Biomechanical Analysis of the Kirschner-Wire Depth of the Modified Tension Band Wiring Technique in Transverse Patellar Fractures: An Experimental Study Using the Finite-Element Method.
Kim Y; Kwon M; Ryu JY; Moon SW
Clin Orthop Surg; 2021 Sep; 13(3):315-319. PubMed ID: 34484623
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]