BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

316 related articles for article (PubMed ID: 33550932)

  • 21. Percutaneous cerclage wiring for type 34-C patella fracture in geriatric patients.
    Zhai Q; Yang J; Zhuang J; Gao R; Chen M
    Injury; 2020 Jun; 51(6):1362-1366. PubMed ID: 32291087
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Open reduction internal fixation of displaced transverse patella fractures with figure-eight wiring through parallel cannulated compression screws.
    Berg EE
    J Orthop Trauma; 1997 Nov; 11(8):573-6. PubMed ID: 9415863
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Progressive migration of broken Kirschner wire into the proximal tibia following tension-band wiring technique of a patellar fracture--case report.
    Konda SR; Dayan A; Egol KA
    Bull NYU Hosp Jt Dis; 2012; 70(4):279-82. PubMed ID: 23267457
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Clinical results of treatment using a modified K-wire tension band versus a cannulated screw tension band in transverse patella fractures: A strobe-compliant retrospective observational study.
    Tan H; Dai P; Yuan Y
    Medicine (Baltimore); 2016 Oct; 95(40):e4992. PubMed ID: 27749556
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Comparison of the cable pin system with conventional open surgery for transverse patella fractures.
    Mao N; Liu D; Ni H; Tang H; Zhang Q
    Clin Orthop Relat Res; 2013 Jul; 471(7):2361-6. PubMed ID: 23529632
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Predictors of postoperative complications of tension band wiring techniques for patella fracture: A retrospective multicenter (TRON group) study.
    Oyama H; Takegami Y; Tokutake K; Murase F; Arakawa O; Oguchi T; Imagama S
    Injury; 2023 Aug; 54(8):110896. PubMed ID: 37349169
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Abstaining from symptomatic implants of modified tension band wiring by nonabsorbable suture fixation for transverse patella fractures.
    Jirangkul P; Kosiyatrakul A
    J Orthop Surg Res; 2021 Jun; 16(1):367. PubMed ID: 34107969
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Self locking tension band technique in transverse patellar fractures.
    Us AK; Kinik H
    Int Orthop; 1996; 20(6):357-8. PubMed ID: 9049763
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Functional outcomes after removal of hardware in patellar fracture: are we helping our patients?
    Greenberg A; Kadar A; Drexler M; Sharfman ZT; Chechik O; Steinberg EL; Snir N
    Arch Orthop Trauma Surg; 2018 Mar; 138(3):325-330. PubMed ID: 29185046
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Locked tension band wiring using ring pins for patellar fractures: a method of minimising implant migration.
    Kim MB; Lee YH; Shin WC; Baek GH
    Arch Orthop Trauma Surg; 2014 Nov; 134(11):1537-43. PubMed ID: 25115235
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Novel techniques demonstrate superior fixation of simple transverse patella fractures - A biomechanical study.
    Lenihan J; Ramos-Pascual S; Silvestros P; Beak P; Miles AW; Trompeter A
    Injury; 2020 Jun; 51(6):1288-1293. PubMed ID: 32276726
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Modified tension band wiring of patellar fracture as a technique to minimize postoperative complications: A case report.
    Yu T; Wu Z; Mohamed SO; Ju W; Liu X; Qi B
    Medicine (Baltimore); 2020 Mar; 99(12):e19576. PubMed ID: 32195969
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Factors influencing K-wire migration in tension-band wiring of olecranon fractures.
    Saeed ZM; Trickett RW; Yewlett AD; Matthews TJ
    J Shoulder Elbow Surg; 2014 Aug; 23(8):1181-6. PubMed ID: 24875733
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Treating patella fractures with a fixed-angle patella plate-A prospective observational study.
    Wild M; Fischer K; Hilsenbeck F; Hakimi M; Betsch M
    Injury; 2016 Aug; 47(8):1737-43. PubMed ID: 27354301
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [Comparative study on the effectiveness of improved and traditional Kirschner wire tension band fixation in treatment of type C patellar fractures].
    Zhang J; Wan S; Zhong Z; Zeng J; Wu C; Tan L; Lin X
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2021 Aug; 35(8):994-999. PubMed ID: 34387428
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Combination of a miniplate with tension band wiring for inferior patellar pole avulsion fractures.
    Zhu W; Xie K; Li X; Li L; Yang J; Xu L; Xu W; Wang X; Fang S
    Injury; 2020 Mar; 51(3):764-768. PubMed ID: 32005322
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A comparison of EFECE systems with tension band wiring for patella fracture fixation in cadavers.
    Karadeniz E; Keskinoz EN
    J Orthop Surg Res; 2020 Jul; 15(1):256. PubMed ID: 32650813
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Management of comminuted patellar fractures using suture reduction technique combined with the modified Kirschner-wire tension band.
    Huang S; Zou C; Kenmegne GR; Yin Y; Lin Y; Fang Y
    BMC Surg; 2023 Aug; 23(1):251. PubMed ID: 37612690
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Open reduction and internal fixation of patellar fractures with tension band wiring through cannulated screws.
    Malik M; Halwai MA
    J Knee Surg; 2014 Oct; 27(5):377-82. PubMed ID: 24414389
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A double button adjustable loop device is biomechanically equivalent to tension band wire in the fixation of transverse patellar fractures-A cadaveric study.
    Han F; Pearce CJ; Ng DQ; Ramruttun AK; Chong DY; Murphy D; Lim CT; Lee BC
    Injury; 2017 Feb; 48(2):270-276. PubMed ID: 27890337
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 16.