136 related articles for article (PubMed ID: 33553543)
21. Comparison of glove donning techniques for the likelihood of gown contamination. An infection control study.
Newman JB; Bullock M; Goyal R
Acta Orthop Belg; 2007 Dec; 73(6):765-71. PubMed ID: 18260491
[TBL] [Abstract][Full Text] [Related]
22. Do surgical helmet systems affect intraoperative wound contamination? A randomised controlled trial.
Shirley OC; Bayan A; Zhu M; Dalton JP; Wiles S; Young SW
Arch Orthop Trauma Surg; 2017 Nov; 137(11):1565-1569. PubMed ID: 28918534
[TBL] [Abstract][Full Text] [Related]
23. Improvising the surgical helmet system for aerosol-generating procedures in the OR: Surgeon designed 3D printed mould for augmented filtration system.
Shah D; Sahu D; Kini A; Bagaria V
J Clin Orthop Trauma; 2021 Jan; 12(1):27-32. PubMed ID: 32994683
[TBL] [Abstract][Full Text] [Related]
24. Does modern space suit reduce intraoperative contamination in total joint replacement? An experimental study.
Nakajima D; Tateiwa T; Masaoka T; Takahashi Y; Shishido T; Yamamoto K
Eur J Orthop Surg Traumatol; 2017 Dec; 27(8):1139-1143. PubMed ID: 27796583
[TBL] [Abstract][Full Text] [Related]
25. Do 'Surgical Helmet Systems' or 'Body Exhaust Suits' Affect Contamination and Deep Infection Rates in Arthroplasty? A Systematic Review.
Young SW; Zhu M; Shirley OC; Wu Q; Spangehl MJ
J Arthroplasty; 2016 Jan; 31(1):225-33. PubMed ID: 26321627
[TBL] [Abstract][Full Text] [Related]
26. Aseptic technique in microgravity.
McCuaig K
Surg Gynecol Obstet; 1992 Nov; 175(5):466-76. PubMed ID: 1440179
[TBL] [Abstract][Full Text] [Related]
27. Glove and gown effects on intraoperative bacterial contamination.
Ward WG; Cooper JM; Lippert D; Kablawi RO; Neiberg RH; Sherertz RJ
Ann Surg; 2014 Mar; 259(3):591-7. PubMed ID: 24045444
[TBL] [Abstract][Full Text] [Related]
28. Surgical area contamination--comparable bacterial counts using disposable head and mask and helmet aspirator system, but dramatic increase upon omission of head-gear: an experimental study in horizontal laminar air-flow.
Friberg B; Friberg S; Ostensson R; Burman LG
J Hosp Infect; 2001 Feb; 47(2):110-5. PubMed ID: 11170774
[TBL] [Abstract][Full Text] [Related]
29. A prospective study on the risk of glove fingertip contamination during draping in joint replacement surgery.
Makki D; Deierl K; Pandit A; Trakru S
Ann R Coll Surg Engl; 2014 Sep; 96(6):434-6. PubMed ID: 25198974
[TBL] [Abstract][Full Text] [Related]
30. Characterizing Particle Evacuation in the Setting of Positive-pressure Body Exhaust Suit Using a Novel Gloving Technique.
Sagers K; Shields JS; Pollock DC; Langfitt MK; Nishiyama SK
J Surg Orthop Adv; 2021; 30(3):166-169. PubMed ID: 34591006
[TBL] [Abstract][Full Text] [Related]
31. Iatrogenic Contamination With a Surgical Helmet System in Orthopedic Surgery.
Eggers JP; Krumme JW; Kotwal S
Orthopedics; 2021; 44(6):e753-e756. PubMed ID: 34618630
[TBL] [Abstract][Full Text] [Related]
32. Dispensing surgical gloves onto the open surgical gown pack does not increase the bacterial contamination rate.
Kong KC; Sheppard M; Serne G
J Hosp Infect; 1994 Apr; 26(4):293-6. PubMed ID: 7915290
[TBL] [Abstract][Full Text] [Related]
33. Comparison of air exhausts for surgical body suits (space suits) and the potential for periprosthetic joint infection.
Ling F; Halabi S; Jones C
J Hosp Infect; 2018 Jul; 99(3):279-283. PubMed ID: 29559232
[TBL] [Abstract][Full Text] [Related]
34. Sterile surgical helmet system in elective total hip and knee arthroplasty.
Singh VK; Hussain S; Javed S; Singh I; Mulla R; Kalairajah Y
J Orthop Surg (Hong Kong); 2011 Aug; 19(2):234-7. PubMed ID: 21857053
[TBL] [Abstract][Full Text] [Related]
35. Influence of intraoperative closed glove exchange on glove contamination during clean soft tissue surgeries.
Sidhu DS; Gull T; Skinner OT
Vet Surg; 2021 Oct; 50(7):1510-1517. PubMed ID: 34286868
[TBL] [Abstract][Full Text] [Related]
36. The effect of the surgical helmet system on intraoperative contamination in arthroplasty surgery.
Chen H; Chan VWK; Yan CH; Fu H; Chan PK; Chiu K
Bone Jt Open; 2023 Nov; 4(11):859-864. PubMed ID: 37952558
[TBL] [Abstract][Full Text] [Related]
37. Glove change to reduce the risk of surgical site infection or prosthetic joint infection in arthroplasty surgeries: a systematic review.
Kim K; Zhu M; Munro JT; Young SW
ANZ J Surg; 2019 Sep; 89(9):1009-1015. PubMed ID: 30497094
[TBL] [Abstract][Full Text] [Related]
38. Non-legislative interventions for the promotion of cycle helmet wearing by children.
Owen R; Kendrick D; Mulvaney C; Coleman T; Royal S
Cochrane Database Syst Rev; 2011 Nov; 2011(11):CD003985. PubMed ID: 22071810
[TBL] [Abstract][Full Text] [Related]
39. Utilization of an Orthopedic Hood as Personal Protective Equipment for Intubation of Coronavirus Patients: a Brief Technical Report.
Wills TT; Zuelzer WA; Tran BW
Geriatr Orthop Surg Rehabil; 2020; 11():2151459320930554. PubMed ID: 32537257
[TBL] [Abstract][Full Text] [Related]
40. Use of a surgical helmet system to minimize splash injury during percutaneous renal surgery in high-risk patients.
Eandi JA; Nanigian DK; Smith WH; Low RK
J Endourol; 2008 Dec; 22(12):2655-6. PubMed ID: 19025395
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]