These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

141 related articles for article (PubMed ID: 335568)

  • 21. Cardiac output by dye dilution using a left carotid loop in conscious rats.
    Matsunaga K; Imamura N; Ueda M
    J Pharmacol Methods; 1980 Aug; 4(1):1-10. PubMed ID: 6995714
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Cardiac output measurement by pulse dye densitometry using three wavelengths.
    Taguchi N; Nakagawa S; Miyasaka K; Fuse M; Aoyagi T
    Pediatr Crit Care Med; 2004 Jul; 5(4):343-50. PubMed ID: 15215003
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Dye-dilution cardiac output without blood withdrawal in the conscious rabbit.
    Boerboom LE; Boelkins JN
    Am J Physiol; 1978 Aug; 235(2):H258-61. PubMed ID: 356628
    [TBL] [Abstract][Full Text] [Related]  

  • 24. IV. Evaluation of dichromatic earpiece densitometry in children with left-to-right shunts.
    Wallgren CG; Kretzschmar G; Zetterqvist P
    Acta Paediatr Scand Suppl; 1975; (254):15-20. PubMed ID: 1101642
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [STUDIES ON THE PRACTICAL CLINICAL APPLICATION OF THE DYE DILUTION METHOD. 1. MEASUREMENT OF RIGHT-LEFT SHUNT CONTROL BY AN EARPIECE DILUTION DENSITOMETER].
    NAKAMURA T; KATORI R; WATANABE T; MIYAZAWA K; MURAI M; ODA J; ISHIKAWA K
    Saishin Igaku; 1965 Mar; 20():635-40. PubMed ID: 14317812
    [No Abstract]   [Full Text] [Related]  

  • 26. Measurement of cardiac output in anesthetized rats by dye dilution using a fiberoptic catheter.
    Sweet CS; Emmert SE; Seymour AA; Stabilito II; Oppenheimer L
    J Pharmacol Methods; 1987 May; 17(3):189-203. PubMed ID: 3302543
    [TBL] [Abstract][Full Text] [Related]  

  • 27. I. Validity of dichnomatic earpiece densitometry for quantitative studies in children with shunt-free cardiovascular malformations.
    Wallgren CG; Hanson JS; Kretzschmar G; Zetterqvist P
    Acta Paediatr Scand Suppl; 1975; (254):1-6. PubMed ID: 1058624
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Application of indicator dye dilution technic to heart diseases. Clinical use of indocyanine green by the earpiece method].
    Kimura N; Utsu N; Nakayama H; Abe T; Kasuga M
    Rinsho Byori; 1969 Aug; 17(8):639-44. PubMed ID: 4902652
    [No Abstract]   [Full Text] [Related]  

  • 29. [A method for correction of abnormal values in measuring cardiac output with the dichromatic earpiece densitometer].
    Yamaguchi I; Komatsu E; Ohnuma O; Kagaya S; Miyazawa K
    Kokyu To Junkan; 1985 Sep; 33(9):1109-14. PubMed ID: 4070822
    [No Abstract]   [Full Text] [Related]  

  • 30. Pulsed dye densitometry with two different sensor types for cardiac output measurement after cardiac surgery: a comparison with the thermodilution technique.
    Hofer CK; Bühlmann S; Klaghofer R; Genoni M; Zollinger A
    Acta Anaesthesiol Scand; 2004 May; 48(5):653-7. PubMed ID: 15101865
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Noninvasive measurement of cardiac output: the continuing saga and lessons learned.
    Jacques S; Goldstein B
    Pediatr Crit Care Med; 2004 Jul; 5(4):410-1. PubMed ID: 15241207
    [No Abstract]   [Full Text] [Related]  

  • 32. [Problem on measurement of cardiac output by earpiece dye dilution method in cases of post operative low output syndrome].
    Ichida S; Masaki S; Ishihara M; Sakakibara H; Tanaka K
    Rinsho Byori; 1982 Jun; 30(6):678-80. PubMed ID: 6752488
    [No Abstract]   [Full Text] [Related]  

  • 33. Electronic calibration for indocyanine dye-dilution curves.
    Sullivan FJ; Mroz EA; Miller RE
    Am Heart J; 1973 Apr; 85(4):506-10. PubMed ID: 4570071
    [No Abstract]   [Full Text] [Related]  

  • 34. The dye dilution method for measurement of cardiac output.
    Lund-Johansen P
    Eur Heart J; 1990 Dec; 11 Suppl I():6-12. PubMed ID: 2092991
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A simple dichromatic densitometer for repeated measurements of cardiac output in small animals.
    Baines AD; Timanoff M; Wong J; Paul W
    Can J Physiol Pharmacol; 1975 Oct; 53(5):704-8. PubMed ID: 1201477
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Cardiac output and circulating blood volume analysis by pulse dye-densitometry.
    Iijima T; Aoyagi T; Iwao Y; Masuda J; Fuse M; Kobayashi N; Sankawa H
    J Clin Monit; 1997 Mar; 13(2):81-9. PubMed ID: 9112203
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Quasi-simultaneous cardiac output determinations in dogs with the direct Fick method (O2 and CO2) and with the dye dilution method using a linear reflection densitometer.
    ten Hoor F; Rispens P; Buursma A; Fongers TM; Jurriëns JM; Zijlma JA
    Pflugers Arch; 1970; 314(2):148-50. PubMed ID: 4903732
    [No Abstract]   [Full Text] [Related]  

  • 38. [Measurement of mean circulation time and cardiac volume by earpiece dilution technic--actual calculation method and evaluation of error factors].
    Watanabe T; Genda M; Ishimi Z
    Naika; 1970 Oct; 26(4):706-11. PubMed ID: 4919225
    [No Abstract]   [Full Text] [Related]  

  • 39. Measurement of blood concentration of indocyanine green by pulse dye densitometry--comparison with the conventional spectrophotometric method.
    Imai T; Takahashi K; Goto F; Morishita Y
    J Clin Monit Comput; 1998 Dec; 14(7-8):477-84. PubMed ID: 10385856
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Measurement of cardiac output with a combined use of earpiece densitometer and ear plethysmography (author's transl)].
    Ichida S; Mori T; Ishihara M; Miyatake K; Sakakibara H
    Rinsho Byori; 1979 Dec; 27(12):1147-50. PubMed ID: 541861
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.