126 related articles for article (PubMed ID: 3356238)
1. Experimental basis of standardized specimen collection: effect of posture on blood picture.
Leppänen EA; Gräsbeck R
Eur J Haematol; 1988 Mar; 40(3):222-6. PubMed ID: 3356238
[TBL] [Abstract][Full Text] [Related]
2. Stability and reproducibility of ADVIA 120-measured red blood cell and platelet parameters in dogs, cats, and horses, and the use of reticulocyte haemoglobin content (CH(R)) in the diagnosis of iron deficiency.
Prins M; van Leeuwen MW; Teske E
Tijdschr Diergeneeskd; 2009 Apr; 134(7):272-8. PubMed ID: 19431960
[TBL] [Abstract][Full Text] [Related]
3. Experimental basis of standardized specimen collection: the effect of the site of venipuncture on the blood picture, the white blood cell differential count, and the serum albumin concentration.
Leppänen EA
Eur J Haematol; 1988 Nov; 41(5):445-8. PubMed ID: 3208867
[TBL] [Abstract][Full Text] [Related]
4. Storage stability of commonly used haematological parameters at 33 °C: Electronic supplementary material available online for this article.
Jain A; Jain S; Singh N; Aswal P; Pal S; Meinia SK; Chowdhury N
Biochem Med (Zagreb); 2018 Jun; 28(2):020901. PubMed ID: 29666560
[TBL] [Abstract][Full Text] [Related]
5. Hematology without the numbers: in-clinic blood film evaluation.
Allison RW; Meinkoth JH
Vet Clin North Am Small Anim Pract; 2007 Mar; 37(2):245-66, vi. PubMed ID: 17336674
[TBL] [Abstract][Full Text] [Related]
6. Stability of complete blood count parameters with storage: toward defined specifications for different diagnostic applications.
Zini G;
Int J Lab Hematol; 2014 Apr; 36(2):111-3. PubMed ID: 24373157
[No Abstract] [Full Text] [Related]
7. Comparison of blood counts in venous, fingertip and arterial blood and their measurement variation.
Yang ZW; Yang SH; Chen L; Qu J; Zhu J; Tang Z
Clin Lab Haematol; 2001 Jun; 23(3):155-9. PubMed ID: 11553055
[TBL] [Abstract][Full Text] [Related]
8. The effect of posture change on blood volume, serum potassium and whole body electrical impedance.
Shirreffs SM; Maughan RJ
Eur J Appl Physiol Occup Physiol; 1994; 69(5):461-3. PubMed ID: 7875146
[TBL] [Abstract][Full Text] [Related]
9. Transillumination: a new tool to eliminate the impact of venous stasis during the procedure for the collection of diagnostic blood specimens for routine haematological testing.
Lima-Oliveira G; Lippi G; Salvagno GL; Montagnana M; Scartezini M; Guidi GC; Picheth G
Int J Lab Hematol; 2011 Oct; 33(5):457-62. PubMed ID: 21414180
[TBL] [Abstract][Full Text] [Related]
10. Effects of posture on concentrations of blood constituents in healthy adults: practical application of blood specimen collection procedures recommended by the Scandinavian Committee on Reference Values.
Felding P; Tryding N; Hyltoft Petersen P; Hørder M
Scand J Clin Lab Invest; 1980; 40(7):615-21. PubMed ID: 7466290
[TBL] [Abstract][Full Text] [Related]
11. Are 10 min of seating enough to guarantee stable haemoglobin and haematocrit readings for the athlete's biological passport?
Ahlgrim C; Pottgiesser T; Robinson N; Sottas PE; Ruecker G; Schumacher YO
Int J Lab Hematol; 2010 Oct; 32(5):506-11. PubMed ID: 20148988
[TBL] [Abstract][Full Text] [Related]
12. Evacuated blood-collection tubes for haematological tests - a quality evaluation prior to their intended use for specimen collection.
Gros N
Clin Chem Lab Med; 2013 May; 51(5):1043-51. PubMed ID: 23079516
[TBL] [Abstract][Full Text] [Related]
13. Postural change during venous blood collection is a major source of bias in clinical chemistry testing.
Lippi G; Salvagno GL; Lima-Oliveira G; Brocco G; Danese E; Guidi GC
Clin Chim Acta; 2015 Feb; 440():164-8. PubMed ID: 25437911
[TBL] [Abstract][Full Text] [Related]
14. A comparison between haematological parameters in 'capillary' and venous blood from healthy adults.
Daae LN; Halvorsen S; Mathisen PM; Mironska K
Scand J Clin Lab Invest; 1988 Nov; 48(7):723-6. PubMed ID: 3201107
[TBL] [Abstract][Full Text] [Related]
15. A new device to relieve venipuncture pain can affect haematology test results.
Lima-Oliveira G; Lippi G; Salvagno GL; Campelo MD; Tajra KS; dos Santos Gomes F; Valentim CD; Romano SJ; Picheth G; Guidi GC
Blood Transfus; 2014 Jan; 12 Suppl 1(Suppl 1):s6-10. PubMed ID: 24120583
[TBL] [Abstract][Full Text] [Related]
16. A comparison between haematological parameters in 'capillary' and venous blood samples from hospitalized children aged 3 months to 14 years.
Daae LN; Hallerud M; Halvorsen S
Scand J Clin Lab Invest; 1991 Nov; 51(7):651-4. PubMed ID: 1810025
[TBL] [Abstract][Full Text] [Related]
17. Changes in major blood components after adopting the supine position during haemodialysis.
Inagaki H; Kuroda M; Watanabe S; Hamazaki T
Nephrol Dial Transplant; 2001 Apr; 16(4):798-802. PubMed ID: 11274277
[TBL] [Abstract][Full Text] [Related]
18. [Effect of body position on laboratory hematological indices].
Penev M; Kereshka P
Vutr Boles; 1988; 27(4):69-72. PubMed ID: 3213027
[TBL] [Abstract][Full Text] [Related]
19. Correlation of the Blood Test Results Obtained between Assays Using Microliter-scale Fingertip Blood Samples Collected with a Novel Blood Collection Device and Conventional Venous Blood Assays: a Secondary Publication in English.
Iwasawa H; Nishimura T; Nemoto S; Aikawa N; Watanabe K
Keio J Med; 2018 Jun; 67(2):26-34. PubMed ID: 29162770
[TBL] [Abstract][Full Text] [Related]
20. A multicentre evaluation of a new filtration protocol for leucocyte depletion of high-haematocrit red blood cells collected by an automated blood collection system.
Soli M; Blanco L; Riggert J; Martínez-Clavel A; Lucas C; Lunghi M; Belloni M; Wolf C; van Waeg G; Antoon M
Vox Sang; 2001; 81(2):108-12. PubMed ID: 11555470
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]