These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

347 related articles for article (PubMed ID: 33566709)

  • 1. Use of a monoblock dual-mobility acetabular component in primary total hip arthroplasty in patients at high risk of dislocation.
    Yang J; Bryan AJ; Drabchuk R; Tetreault MW; Calkins TE; Della Valle CJ
    Hip Int; 2022 Sep; 32(5):648-655. PubMed ID: 33566709
    [TBL] [Abstract][Full Text] [Related]  

  • 2. What Is the Risk of Dislocation and Revision in Proximal Femoral Replacement with Dual-mobility Articulation After Two-stage Revision for Periprosthetic Hip Infection?
    Theil C; Schwarze J; Smolle MA; Pützler J; Moellenbeck B; Schneider KN; Schulze M; Klingebiel S; Gosheger G
    Clin Orthop Relat Res; 2023 Sep; 481(9):1792-1799. PubMed ID: 36897193
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Cementless hydroxyapatite-coated stem with dual mobility and posterior approach in over-80 year-old patients with osteoarthritis: Rates of dislocation and periprosthetic fracture at a mean 8 years' follow-up.
    Belgaïd V; Viste A; Fessy MH
    Orthop Traumatol Surg Res; 2022 Apr; 108(2):103196. PubMed ID: 34958972
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dual Mobility Acetabular Cups in Primary Total Hip Arthroplasty in Patients at High Risk for Dislocation.
    Harwin SF; Mistry JB; Chughtai M; Khlopas A; Gwam C; Newman JM; Higuera CA; Bonutti PM; Malkani AL; Kolisek FR; Delanois RE; Mont MA
    Surg Technol Int; 2017 Jul; 30():251-258. PubMed ID: 28395391
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Total Hip Arthroplasty in Patients With Parkinson Disease: Improved Outcomes With Dual Mobility Implants and Cementless Fixation.
    Lazennec JY; Kim Y; Pour AE
    J Arthroplasty; 2018 May; 33(5):1455-1461. PubMed ID: 29276118
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Low Frequency of Early Complications With Dual-mobility Acetabular Cups in Cementless Primary THA.
    Chughtai M; Mistry JB; Diedrich AM; Jauregui JJ; Elmallah RK; Bonutti PM; Harwin SF; Malkani AL; Kolisek FR; Mont MA
    Clin Orthop Relat Res; 2016 Oct; 474(10):2181-7. PubMed ID: 27106128
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Is Isolated Mobile Component Exchange an Option in the Management of Intraprosthetic Dislocation of a Dual Mobility Cup?
    Wegrzyn J; Malatray M; Pibarot V; Anania G; Béjui-Hugues J
    Clin Orthop Relat Res; 2020 Feb; 478(2):279-287. PubMed ID: 31794492
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Is there a problem with modular dual mobility acetabular components in revision total hip arthroplasty at mid-term follow-up?
    Hernandez NM; Hinton ZW; Wu CJ; Lachiewicz PF; Ryan SP; Wellman SS
    Bone Joint J; 2021 Jul; 103-B(7 Supple B):66-72. PubMed ID: 34192910
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The benefit of the systematic revision of the acetabular implant in favor of a dual mobility articulation during the treatment of periprosthetic fractures of the femur: a 49 cases prospective comparative study.
    Perrin A; Saab M; Putman S; Benad K; Drumez E; Chantelot C
    Eur J Orthop Surg Traumatol; 2018 Feb; 28(2):239-246. PubMed ID: 28900737
    [TBL] [Abstract][Full Text] [Related]  

  • 10. In Revision THA, Is the Re-revision Risk for Dislocation and Aseptic Causes Greater in Dual-mobility Constructs or Large Femoral Head Bearings? A Study from the Australian Orthopaedic Association National Joint Replacement Registry.
    Hoskins W; Rainbird S; Dyer C; Graves SE; Bingham R
    Clin Orthop Relat Res; 2022 Jun; 480(6):1091-1101. PubMed ID: 34978538
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Outcomes of revision total hip arthroplasty using the modular dual mobility acetabular system to treat recurrent dislocation.
    Park CW; Lim SJ; Kim IS; Jang MC; Moon YW; Park YS
    Int Orthop; 2022 Apr; 46(4):789-795. PubMed ID: 35064307
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Influence of dual-mobility acetabular implants on revision and survivorship of cup and Kerboull-type reinforcement ring constructs in aseptic acetabular loosening.
    Bozon O; Dagneaux L; Sanchez T; Gaillard F; Hamoui M; Canovas F
    Orthop Traumatol Surg Res; 2022 Apr; 108(2):103071. PubMed ID: 34560312
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Is There a Benefit to Modularity in 'Simpler' Femoral Revisions?
    Huddleston JI; Tetreault MW; Yu M; Bedair H; Hansen VJ; Choi HR; Goodman SB; Sporer SM; Della Valle CJ
    Clin Orthop Relat Res; 2016 Feb; 474(2):415-20. PubMed ID: 26245164
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Total Hip Arthroplasties for Hartofilakidis Type C1 and C2 High Hip Dislocations Demonstrate Similar Survivorship and Clinical Function at Minimum 10-year Follow-up With Cementless Implants.
    Huang Y; Zhou Y; Shao H; Chu Y; Gu J; Li H
    J Arthroplasty; 2022 Dec; 37(12):2374-2380. PubMed ID: 35709909
    [TBL] [Abstract][Full Text] [Related]  

  • 15. What is the failure rate of constrained liners in complex revision total hip arthroplasty?
    Unter Ecker N; Piakong P; Delgado G; Gehrke T; Citak M; Ohlmeier M
    Arch Orthop Trauma Surg; 2023 Mar; 143(3):1671-1678. PubMed ID: 35377048
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Dual mobility cups associated with proximal femoral replacement in nontumoral indications: Results and complications.
    Canetti R; Malatray M; Pibarot V; Wegrzyn J
    Orthop Traumatol Surg Res; 2022 Apr; 108(2):103029. PubMed ID: 34343696
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Do alumina matrix composite bearings decrease hip noises and bearing fractures at a minimum of 5 years after THA?
    Baek SH; Kim WK; Kim JY; Kim SY
    Clin Orthop Relat Res; 2015 Dec; 473(12):3796-802. PubMed ID: 26126991
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Monolithic Dual Mobility Cup Total Hip Arthroplasty Has High Complication Rates With Surgical Fixation in Elderly With Femur Neck Fracture.
    Sunilkumar PD; Oh KJ; Cho HW; Kim SM
    J Arthroplasty; 2020 Dec; 35(12):3621-3626. PubMed ID: 32773273
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Revision hip arthroplasty dislocation risk calculator: when to select dual mobility, large heads, constrained liners, or a standard head size? Testing one hundred thousand hip revisions with artificial intelligence.
    Hernigou P; Tannyeres P; Barbier O; Chenaie P
    Int Orthop; 2023 Aug; 47(8):2003-2011. PubMed ID: 37326696
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Outcomes of Dual Mobility Acetabular Cups in Total Hip Arthroplasty Patients.
    Harwin SF; Sodhi N; Ehiorobo J; Khlopas A; Sultan AA; Mont MA
    Surg Technol Int; 2019 May; 34():367-370. PubMed ID: 30500976
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 18.