BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

309 related articles for article (PubMed ID: 33577113)

  • 1. Development of a mechatronic guidance system for targeted ultrasound-guided biopsy under high-resolution positron emission mammography localization.
    Park CKS; Bax JS; Gardi L; Knull E; Fenster A
    Med Phys; 2021 Apr; 48(4):1859-1873. PubMed ID: 33577113
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Stereotactic mammography imaging combined with 3D US imaging for image guided breast biopsy.
    Surry KJ; Mills GR; Bevan K; Downey DB; Fenster A
    Med Phys; 2007 Nov; 34(11):4348-58. PubMed ID: 18072500
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A needle guidance system for biopsy and therapy using two-dimensional ultrasound.
    Bluvol N; Sheikh A; Kornecki A; Fernandez Ddel R; Downey D; Fenster A
    Med Phys; 2008 Feb; 35(2):617-28. PubMed ID: 18383683
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Positron emission mammography-guided breast biopsy.
    Raylman RR; Majewski S; Weisenberger AG; Popov V; Wojcik R; Kross B; Schreiman JS; Bishop HA
    J Nucl Med; 2001 Jun; 42(6):960-6. PubMed ID: 11390563
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Design of an end-effector for robot-assisted ultrasound-guided breast biopsies.
    Welleweerd MK; Siepel FJ; Groenhuis V; Veltman J; Stramigioli S
    Int J Comput Assist Radiol Surg; 2020 Apr; 15(4):681-690. PubMed ID: 32100177
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Geometrically variable three-dimensional ultrasound for mechanically assisted image-guided therapy of focal liver cancer tumors.
    Gillies DJ; Bax J; Barker K; Gardi L; Kakani N; Fenster A
    Med Phys; 2020 Oct; 47(10):5135-5146. PubMed ID: 32686142
    [TBL] [Abstract][Full Text] [Related]  

  • 7. PET/CT-guided biopsy with respiratory motion correction.
    Zhang R; Zukić D; Byrd DW; Enquobahrie A; Alessio AM; Cleary K; Banovac F; Kinahan PE
    Int J Comput Assist Radiol Surg; 2019 Dec; 14(12):2187-2198. PubMed ID: 31512193
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The positron emission mammography/tomography breast imaging and biopsy system (PEM/PET): design, construction and phantom-based measurements.
    Raylman RR; Majewski S; Smith MF; Proffitt J; Hammond W; Srinivasan A; McKisson J; Popov V; Weisenberger A; Judy CO; Kross B; Ramasubramanian S; Banta LE; Kinahan PE; Champley K
    Phys Med Biol; 2008 Feb; 53(3):637-53. PubMed ID: 18199907
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Real-time registration of 3D to 2D ultrasound images for image-guided prostate biopsy.
    Gillies DJ; Gardi L; De Silva T; Zhao SR; Fenster A
    Med Phys; 2017 Sep; 44(9):4708-4723. PubMed ID: 28666058
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Development of a 3D ultrasound guidance system for permanent breast seed implantation.
    Michael J; Morton D; Batchelar D; Hilts M; Crook J; Fenster A
    Med Phys; 2018 May; ():. PubMed ID: 29791029
    [TBL] [Abstract][Full Text] [Related]  

  • 11. 3D ultrasound guided breast biopsy system.
    Fenster A; Surry KJ; Mills GR; Downey DB
    Ultrasonics; 2004 Apr; 42(1-9):769-74. PubMed ID: 15047381
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Assessment of image registration accuracy in three-dimensional transrectal ultrasound guided prostate biopsy.
    Karnik VV; Fenster A; Bax J; Cool DW; Gardi L; Gyacskov I; Romagnoli C; Ward AD
    Med Phys; 2010 Feb; 37(2):802-13. PubMed ID: 20229890
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of an electromagnetic image-fusion navigation system for biopsy of small lesions: assessment of accuracy in an in vivo swine model.
    Appelbaum L; Solbiati L; Sosna J; Nissenbaum Y; Greenbaum N; Goldberg SN
    Acad Radiol; 2013 Feb; 20(2):209-17. PubMed ID: 23395242
    [TBL] [Abstract][Full Text] [Related]  

  • 14. 3D image-guided robotic needle positioning system for small animal interventions.
    Bax JS; Waring CS; Sherebrin S; Stapleton S; Hudson TJ; Jaffray DA; Lacefield JC; Fenster A
    Med Phys; 2013 Jan; 40(1):011909. PubMed ID: 23298100
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Positional calibration of an ultrasound image-guided robotic breast biopsy system.
    Nelson TR; Tran A; Fakourfar H; Nebeker J
    J Ultrasound Med; 2012 Mar; 31(3):351-9. PubMed ID: 22368125
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A comparison of prostate tumor targeting strategies using magnetic resonance imaging-targeted, transrectal ultrasound-guided fusion biopsy.
    Martin PR; Cool DW; Fenster A; Ward AD
    Med Phys; 2018 Mar; 45(3):1018-1028. PubMed ID: 29363762
    [TBL] [Abstract][Full Text] [Related]  

  • 17. 3-Dimensional elastic registration system of prostate biopsy location by real-time 3-dimensional transrectal ultrasound guidance with magnetic resonance/transrectal ultrasound image fusion.
    Ukimura O; Desai MM; Palmer S; Valencerina S; Gross M; Abreu AL; Aron M; Gill IS
    J Urol; 2012 Mar; 187(3):1080-6. PubMed ID: 22266005
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Magnetic resonance imaging-targeted, 3D transrectal ultrasound-guided fusion biopsy for prostate cancer: Quantifying the impact of needle delivery error on diagnosis.
    Martin PR; Cool DW; Romagnoli C; Fenster A; Ward AD
    Med Phys; 2014 Jul; 41(7):073504. PubMed ID: 24989418
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A novel MR-guided interventional device for 3D circumferential access to breast tissue.
    Smith M; Zhai X; Harter R; Sisney G; Elezabye M; Fain S
    Med Phys; 2008 Aug; 35(8):3779-86. PubMed ID: 18777937
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Position-based modeling of lesion displacement in ultrasound-guided breast biopsy.
    Tagliabue E; Dall'Alba D; Magnabosco E; Tenga C; Peterlik I; Fiorini P
    Int J Comput Assist Radiol Surg; 2019 Aug; 14(8):1329-1339. PubMed ID: 31161556
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.