  • 41. Validation of two devices for self-measurement of blood pressure by elderly patients according to the revised British Hypertension Society protocol: the Omron HEM-722C and HEM-735C.
    Bortolotto LA; Henry O; Hanon O; Sikias P; Mourad JJ; Girerd X
    Blood Press Monit; 1999 Feb; 4(1):21-5. PubMed ID: 10362887
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Validation of the G.LAB MD41A0 upper arm blood pressure monitor in patients with diabetes mellitus according to the AAMI/ESH/ISO 81060-2:2018 Universal Standard.
    Li LY; Tian L; Gao B; Ming J; Liu K; Jiang J; Han ZY; Zhao LY; Chen CS; Wan Y
    Blood Press Monit; 2022 Aug; 27(4):280-284. PubMed ID: 35258022
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Validation of an automatic device for the self-measurement of blood pressure in sitting and supine positions according to the ANSI/AAMI/ISO81060-2: 2013 guidelines: the Omron HEM-9700T.
    Kuwabara M; Harada K; Hishiki Y; Kario K
    Blood Press Monit; 2019 Jun; 24(3):146-150. PubMed ID: 31026232
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Validation of the ABPMpro ambulatory blood pressure monitor in the general population according to AAMI/ESH/ISO Universal Standard (ISO 81060-2:2018).
    Roth B; Bothe TL; Patzak A; Pilz N
    Blood Press Monit; 2023 Jun; 28(3):158-162. PubMed ID: 37016982
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Validation of a novel professional automated auscultatory upper-arm cuff blood pressure monitor in a general population according to the AAMI/ESH/ISO Universal Standard: KOROT V2 Doctor (InBody BPBIO280KV).
    Theodosiadi A; Ntousopoulos V; Ntineri A; Stathopoulou P; Menti A; Kyriakoulis KG; Kollias A; Stergiou GS
    Blood Press Monit; 2024 Aug; 29(4):212-216. PubMed ID: 38946333
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Validation of an automated home blood pressure measurement device in oldest-old populations.
    Godai K; Kabayama M; Saito K; Asayama K; Yamamoto K; Sugimoto K; Ohkubo T; Rakugi H; Kamide K
    Hypertens Res; 2020 Jan; 43(1):30-35. PubMed ID: 31534190
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Simultaneous validation of the SunTech CT40 automated blood pressure measurement device by the 1993 British Hypertension Society protocol and the Association for the Advancement of Medical Instrumentation/International Organization for Standardization 81060-2: 2013 standard.
    Polo Friz H; Punzi V; Petri F; Orlandi R; Maggiolini D; Polo Friz M; Primitz L; Vighi G
    Blood Press Monit; 2017 Oct; 22(5):298-301. PubMed ID: 28763332
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Validation of the InBody BPBIO210 manual auscultatory hybrid device for professional office use in a general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization Universal Standard.
    Ntineri A; Menti A; Kyriakoulis KG; Bountzona I; Prapa S; Kollias A; Stergiou GS
    Blood Press Monit; 2022 Apr; 27(2):135-138. PubMed ID: 34636810
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Validation of the InBody BPBIO250 oscillometric blood pressure monitor for professional office use in general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization Universal Standard.
    Kollias A; Gravvani A; Anagnostopoulos I; Kyriakoulis KG; Bountzona I; Menti A; Stergiou GS
    Blood Press Monit; 2020 Apr; 25(2):115-117. PubMed ID: 31913149
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Validation of the Raycome model M2 ambulatory blood pressure monitor in the general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization Universal Standard (ISO 81060-2:2018).
    Yang S; Zhou Z; Miao H; Zhang H; Zhou Q; Zhai M; Zhang Y
    Blood Press Monit; 2024 Jun; 29(3):161-165. PubMed ID: 38390625
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Validation of the DBP-1333b upper-arm blood pressure monitor according to the AAMI/ESH/ISO universal standard (ISO 81060-2:2018+Amd.1:2020).
    Hou G; Wu Y; Wang J; Zhi J
    Blood Press Monit; 2024 Jun; 29(3):149-155. PubMed ID: 38193368
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Validation of the Wellvii VitalDetect blood pressure monitor in general population according to the International Standardization Organization 81060-2:2018.
    Li LY; Chen JF; Bing S; Liu K; Cheng R; Wan Y
    Blood Press Monit; 2024 Apr; 29(2):93-98. PubMed ID: 37997441
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Validation of a wrist-type home nocturnal blood pressure monitor in the sitting and supine position according to the ANSI/AAMI/ISO81060-2:2013 guidelines: Omron HEM-9600T.
    Kuwabara M; Harada K; Hishiki Y; Kario K
    J Clin Hypertens (Greenwich); 2019 Apr; 21(4):463-469. PubMed ID: 30609129
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Simultaneous validation of the SunTech 247 diagnostic station blood pressure measurement device according to the British Hypertension Society protocol, the International Protocol and the Association for the Advancement of Medical Instrumentation standards.
    Polo Friz H; Facchetti R; Primitz L; Beltrame L; Galbiati V; Ricioppo A; Bombelli M; Sega R
    Blood Press Monit; 2009 Oct; 14(5):222-7. PubMed ID: 19741510
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Validation of the YuWell YE900 oscillometric blood pressure monitor for professional office use in adults and children according to the AAMI/ESH/ISO Universal Standard (ISO 81060-2:2018).
    Zhang HJ; Zhang J; Wang SL; Zhang J; Teng LN; Zhang SJ; Zhou DJ; Long MZ
    Blood Press Monit; 2021 Oct; 26(5):396-399. PubMed ID: 34480474
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Clinical Accuracy of the Withings BPM Connect for Self-Blood Pressure Measurements in Pregnancy and Pre-Eclampsia: Validation According to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization Universal Standard.
    Zelveian P; Topouchian J; Hakobyan Z; Asmar J; Gharibyan H; Asmar R
    Vasc Health Risk Manag; 2022; 18():181-189. PubMed ID: 35370407
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Preliminary assessment of video-based blood pressure measurement according to ANSI/AAMI/ISO81060-2: 2013 guideline accuracy criteria: Anura smartphone app with transdermal optimal imaging technology.
    Yang D; Xiao G; Wei J; Luo H
    Blood Press Monit; 2020 Oct; 25(5):295-298. PubMed ID: 32842022
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Validation of the watch-type HUAWEI WATCH D oscillometric wrist blood pressure monitor in adult Chinese.
    Zhang W; Zhou YN; Zhou Y; Wang JG
    Blood Press Monit; 2022 Oct; 27(5):353-356. PubMed ID: 35687029
    [TBL] [Abstract][Full Text] [Related]  

  • 59. [Evaluation and validation of Omron Hem 705 CP and Hem 706/711 monitors for self-measurement of blood pressure].
    Artigao LM; Llavador JJ; Puras A; López Abril J; Rubio MM; Torres C; Vidal A; Sanchis C; Divisón JA; Naharro F; Caldevilla D; Fuentes G
    Aten Primaria; 2000 Feb; 25(2):96-102. PubMed ID: 10736939
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Evaluation of three devices for self-measurement of blood pressure according to the revised British Hypertension Society Protocol: the Omron HEM-705CP, Philips HP5332, and Nissei DS-175.
    O'Brien E; Mee F; Atkins N; Thomas M
    Blood Press Monit; 1996 Feb; 1(1):55-61. PubMed ID: 10226203
    [TBL] [Abstract][Full Text] [Related]  