167 related articles for article (PubMed ID: 33578024)
1. Intraoperative Computed Tomography-Assisted Spinal Navigation in Dorsal Cervical Instrumentation: A Prospective Study on Accuracy Regarding Different Pathologies and Screw Types.
Bertram U; Schmidt TP; Clusmann H; Albanna W; Herren C; Riabikin A; Mueller CA; Blume C
World Neurosurg; 2021 May; 149():e378-e385. PubMed ID: 33578024
[TBL] [Abstract][Full Text] [Related]
2. Intraoperative Computed Tomography Versus 3D C-Arm Imaging for Navigated Spinal Instrumentation.
Hecht N; Yassin H; Czabanka M; Föhre B; Arden K; Liebig T; Vajkoczy P
Spine (Phila Pa 1976); 2018 Mar; 43(5):370-377. PubMed ID: 28368989
[TBL] [Abstract][Full Text] [Related]
3. Use of Intraoperative CT Improves Accuracy of Spinal Navigation During Screw Fixation in Cervico-thoracic Region.
Habib N; Filardo G; Distefano D; Candrian C; Reinert M; Scarone P
Spine (Phila Pa 1976); 2021 Apr; 46(8):530-537. PubMed ID: 33273435
[TBL] [Abstract][Full Text] [Related]
4. Comparison of intraoperative CT- and cone beam CT-based spinal navigation for the treatment of atlantoaxial instability.
Haemmerli J; Ferdowssian K; Wessels L; Mertens R; Hecht N; Woitzik J; Schneider UC; Bayerl SH; Vajkoczy P; Czabanka M
Spine J; 2023 Dec; 23(12):1799-1807. PubMed ID: 37619869
[TBL] [Abstract][Full Text] [Related]
5. Accuracy of image-guided pedicle screw placement using intraoperative computed tomography-based navigation with automated referencing, part I: cervicothoracic spine.
Scheufler KM; Franke J; Eckardt A; Dohmen H
Neurosurgery; 2011 Oct; 69(4):782-95; discussion 795. PubMed ID: 21552171
[TBL] [Abstract][Full Text] [Related]
6. Use of the Airo mobile intraoperative CT system versus the O-arm for transpedicular screw fixation in the thoracic and lumbar spine: a retrospective cohort study of 263 patients.
Scarone P; Vincenzo G; Distefano D; Del Grande F; Cianfoni A; Presilla S; Reinert M
J Neurosurg Spine; 2018 Oct; 29(4):397-406. PubMed ID: 29979141
[TBL] [Abstract][Full Text] [Related]
7. Accuracy of image-guided pedicle screw placement using intraoperative computed tomography-based navigation with automated referencing. Part II: thoracolumbar spine.
Scheufler KM; Franke J; Eckardt A; Dohmen H
Neurosurgery; 2011 Dec; 69(6):1307-16. PubMed ID: 21734616
[TBL] [Abstract][Full Text] [Related]
8. Surgical safety of cervical pedicle screw placement with computer navigation system.
Shimokawa N; Takami T
Neurosurg Rev; 2017 Apr; 40(2):251-258. PubMed ID: 27245606
[TBL] [Abstract][Full Text] [Related]
9. Accuracy of Intraoperative Computed Tomography Assisted Dorsal Instrumentation in Spinal Revision Surgery.
Bertram U; Clusmann H; Geiger MF; Riabikin A; Mueller CA; Blume C
J Neurol Surg A Cent Eur Neurosurg; 2021 May; 82(3):191-196. PubMed ID: 33386027
[TBL] [Abstract][Full Text] [Related]
10. Standard navigation versus intraoperative computed tomography navigation in upper cervical spine trauma.
Carl B; Bopp M; Pojskic M; Voellger B; Nimsky C
Int J Comput Assist Radiol Surg; 2019 Jan; 14(1):169-182. PubMed ID: 30171444
[TBL] [Abstract][Full Text] [Related]
11. Total Navigation in Spine Surgery; A Concise Guide to Eliminate Fluoroscopy Using a Portable Intraoperative Computed Tomography 3-Dimensional Navigation System.
Navarro-Ramirez R; Lang G; Lian X; Berlin C; Janssen I; Jada A; Alimi M; Härtl R
World Neurosurg; 2017 Apr; 100():325-335. PubMed ID: 28104526
[TBL] [Abstract][Full Text] [Related]
12. Accuracy of freehand pedicle screws versus lateral mass screws in the subaxial cervical spine.
Hey HWD; Zhuo WH; Tan YHJ; Tan JH
Spine Deform; 2020 Oct; 8(5):1049-1058. PubMed ID: 32314180
[TBL] [Abstract][Full Text] [Related]
13. Navigated percutaneous versus open pedicle screw implantation using intraoperative CT and robotic cone-beam CT imaging.
Tkatschenko D; Kendlbacher P; Czabanka M; Bohner G; Vajkoczy P; Hecht N
Eur Spine J; 2020 Apr; 29(4):803-812. PubMed ID: 31820094
[TBL] [Abstract][Full Text] [Related]
14. CT-Navigated Spinal Instrumentations-Three-Dimensional Evaluation of Screw Placement Accuracy in Relation to a Screw Trajectory Plan.
Gubian A; Kausch L; Neumann JO; Kiening K; Ishak B; Maier-Hein K; Unterberg A; Scherer M
Medicina (Kaunas); 2022 Sep; 58(9):. PubMed ID: 36143877
[TBL] [Abstract][Full Text] [Related]
15. The "slide technique"-a novel free-hand method of subaxial cervical pedicle screw placement.
Liu B; Liu X; Shen X; Wang G; Chen Y
BMC Musculoskelet Disord; 2020 Jun; 21(1):399. PubMed ID: 32576178
[TBL] [Abstract][Full Text] [Related]
16. Accuracy and workflow of navigated spinal instrumentation with the mobile AIRO(®) CT scanner.
Hecht N; Kamphuis M; Czabanka M; Hamm B; König S; Woitzik J; Synowitz M; Vajkoczy P
Eur Spine J; 2016 Mar; 25(3):716-23. PubMed ID: 25702317
[TBL] [Abstract][Full Text] [Related]
17. Accuracy of CT-navigated pedicle screw positioning in the cervical and upper thoracic region with and without prior anterior surgery and ventral plating.
Rienmüller A; Buchmann N; Kirschke JS; Meyer EL; Gempt J; Lehmberg J; Meyer B; Ryang YM
Bone Joint J; 2017 Oct; 99-B(10):1373-1380. PubMed ID: 28963160
[TBL] [Abstract][Full Text] [Related]
18. Intraoperative computed tomography image-guided navigation for posterior thoracolumbar spinal instrumentation in spinal deformity surgery.
Tormenti MJ; Kostov DB; Gardner PA; Kanter AS; Spiro RM; Okonkwo DO
Neurosurg Focus; 2010 Mar; 28(3):E11. PubMed ID: 20192656
[TBL] [Abstract][Full Text] [Related]
19. O-Arm Navigated Cervical Pedicle Screw Fixation in the Treatment of Lower Cervical Fracture-Dislocation.
Zhang K; Chen H; Chen K; Yang P; Yang H; Mao H
Orthop Surg; 2022 Jun; 14(6):1135-1142. PubMed ID: 35524652
[TBL] [Abstract][Full Text] [Related]
20. Safety and accuracy of robot-assisted versus fluoroscopy-guided pedicle screw insertion for degenerative diseases of the lumbar spine: a matched cohort comparison.
Schatlo B; Molliqaj G; Cuvinciuc V; Kotowski M; Schaller K; Tessitore E
J Neurosurg Spine; 2014 Jun; 20(6):636-43. PubMed ID: 24725180
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]