These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

140 related articles for article (PubMed ID: 33578685)

  • 1. Custom-Made Zirconium Dioxide Implants for Craniofacial Bone Reconstruction.
    Kozakiewicz M; Gmyrek T; Zajdel R; Konieczny B
    Materials (Basel); 2021 Feb; 14(4):. PubMed ID: 33578685
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Guided bone regeneration at zirconia and titanium dental implants: a pilot histological investigation.
    Benic GI; Thoma DS; Sanz-Martin I; Munoz F; Hämmerle CHF; Cantalapiedra A; Fischer J; Jung RE
    Clin Oral Implants Res; 2017 Dec; 28(12):1592-1599. PubMed ID: 28653343
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Assessment of peri-implant defects at titanium and zirconium dioxide implants by means of periapical radiographs and cone beam computed tomography: An in-vitro examination.
    Steiger-Ronay V; Krcmaric Z; Schmidlin PR; Sahrmann P; Wiedemeier DB; Benic GI
    Clin Oral Implants Res; 2018 Dec; 29(12):1195-1201. PubMed ID: 30387207
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Titanium and zirconium release from titanium- and zirconia implants in mini pig maxillae and their toxicity in vitro.
    He X; Reichl FX; Milz S; Michalke B; Wu X; Sprecher CM; Yang Y; Gahlert M; Röhling S; Kniha H; Hickel R; Högg C
    Dent Mater; 2020 Mar; 36(3):402-412. PubMed ID: 31992485
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Ligature-Induced Peri-implant Bone Loss Around Loaded Zirconia and Titanium Implants.
    Roehling S; Gahlert M; Janner S; Meng B; Woelfler H; Cochran DL
    Int J Oral Maxillofac Implants; 2019; 34(2):357–365. PubMed ID: 30716147
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Osseointegration of zirconia implants: an SEM observation of the bone-implant interface.
    Depprich R; Zipprich H; Ommerborn M; Mahn E; Lammers L; Handschel J; Naujoks C; Wiesmann HP; Kübler NR; Meyer U
    Head Face Med; 2008 Nov; 4():25. PubMed ID: 18990214
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Loaded custom-made zirconia and titanium implants show similar osseointegration: an animal experiment.
    Kohal RJ; Weng D; Bächle M; Strub JR
    J Periodontol; 2004 Sep; 75(9):1262-8. PubMed ID: 15515343
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Controllable biodegradation and enhanced osseointegration of ZrO
    Yuan W; Xia D; Zheng Y; Liu X; Wu S; Li B; Han Y; Jia Z; Zhu D; Ruan L; Takashima K; Liu Y; Zhou Y
    Acta Biomater; 2020 Mar; 105():290-303. PubMed ID: 31972366
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A prospective clinical study to evaluate the performance of zirconium dioxide dental implants in single-tooth edentulous area: 3-year follow-up.
    Bormann KH; Gellrich NC; Kniha H; Schild S; Weingart D; Gahlert M
    BMC Oral Health; 2018 Nov; 18(1):181. PubMed ID: 30382850
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Ceramic and PMMA particles differentially affect osteoblast phenotype.
    Lohmann CH; Dean DD; Köster G; Casasola D; Buchhorn GH; Fink U; Schwartz Z; Boyan BD
    Biomaterials; 2002 Apr; 23(8):1855-63. PubMed ID: 11950056
    [TBL] [Abstract][Full Text] [Related]  

  • 11. In vivo performance of zirconia and titanium implants: a histomorphometric study in mini pig maxillae.
    Gahlert M; Roehling S; Sprecher CM; Kniha H; Milz S; Bormann K
    Clin Oral Implants Res; 2012 Mar; 23(3):281-6. PubMed ID: 21806681
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Cone beam computed tomography artefacts around dental implants with different materials influencing the detection of peri-implant bone defects.
    Schriber M; Yeung AWK; Suter VGA; Buser D; Leung YY; Bornstein MM
    Clin Oral Implants Res; 2020 Jul; 31(7):595-606. PubMed ID: 32147872
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of plasma-sprayed hydroxyapatite coatings and zirconia-reinforced hydroxyapatite composite coatings: in vivo study.
    Lee TM; Yang CY; Chang E; Tsai RS
    J Biomed Mater Res A; 2004 Dec; 71(4):652-60. PubMed ID: 15505828
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Custom-made implants for craniofacial reconstruction].
    Jalbert F; Lauwers F
    Rev Stomatol Chir Maxillofac Chir Orale; 2013 Sep; 114(4):211-218. PubMed ID: 23911530
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The effect of polyelectrolyte multilayer coated titanium alloy surfaces on implant anchorage in rats.
    Zankovych S; Diefenbeck M; Bossert J; Mückley T; Schrader C; Schmidt J; Schubert H; Bischoff S; Faucon M; Finger U; Jandt KD
    Acta Biomater; 2013 Jan; 9(1):4926-34. PubMed ID: 22902814
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Radio-opaque polyethylene for personalized craniomaxillofacial implants.
    Kozakiewicz M; Olbrzymek L; Stefanczyk L; Olszycki M; Komorowski P; Walkowiak B; Konieczny B; Krasowski M; Sokołowski J
    Clin Oral Investig; 2017 Jun; 21(5):1853-1859. PubMed ID: 27766488
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A prospective clinical study to evaluate the performance of zirconium dioxide dental implants in single-tooth gaps.
    Gahlert M; Kniha H; Weingart D; Schild S; Gellrich NC; Bormann KH
    Clin Oral Implants Res; 2016 Dec; 27(12):e176-e184. PubMed ID: 25827600
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Acid and alkaline etching of sandblasted zirconia implants: a histomorphometric study in miniature pigs.
    Saulacic N; Erdösi R; Bosshardt DD; Gruber R; Buser D
    Clin Implant Dent Relat Res; 2014 Jun; 16(3):313-22. PubMed ID: 23574426
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A comparison of biocompatibility and osseointegration of ceramic and titanium implants: an in vivo and in vitro study.
    Möller B; Terheyden H; Açil Y; Purcz NM; Hertrampf K; Tabakov A; Behrens E; Wiltfang J
    Int J Oral Maxillofac Surg; 2012 May; 41(5):638-45. PubMed ID: 22406235
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Peri-implant soft tissue analyses comparing Ti and ZrO
    Blanco J; Caneiro L; Liñares A; Batalla P; Muñoz F; Ramos I
    Clin Oral Implants Res; 2016 Oct; 27(10):1221-1226. PubMed ID: 27699885
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.