136 related articles for article (PubMed ID: 33582082)
1. Cardiac Tamponade Due to Very Late Perforation of Left Atrium by Atrial Septal Defect Occluder.
Tsinivizov P; Giannakopoulos A; Varvarousis D; Michelinakis N; Koumallos N; Manolis AJ
JACC Cardiovasc Interv; 2021 Mar; 14(5):e49-e51. PubMed ID: 33582082
[No Abstract] [Full Text] [Related]
2. Pericardial tamponade due to erosion of a Figulla Flex II device after closure of an atrial septal defect.
Abe T; Tsukano S; Tosaka Y
Catheter Cardiovasc Interv; 2019 Dec; 94(7):1003-1005. PubMed ID: 31194277
[TBL] [Abstract][Full Text] [Related]
3. Late tissue erosion after transcatheter closure of an atrial septal defect.
Mendirichaga R; Smairat RA; Sancassani R
Catheter Cardiovasc Interv; 2017 Feb; 89(3):502-504. PubMed ID: 26527464
[TBL] [Abstract][Full Text] [Related]
4. Cardiac tamponade due to perforation by an Amplatzer atrial septal occluder in a patient with Marfan syndrome.
Tateishi M; Hiramatsu T; Tomizawa Y; Matsumura G; Konuma T; Yamazaki K; Yamamura H; Nakanishi T
J Artif Organs; 2011 Sep; 14(3):261-3. PubMed ID: 21637960
[TBL] [Abstract][Full Text] [Related]
5. Fatal Erosion Atrial Septal Defect Device.
Kister T; Dähnert I; Lurz P
Catheter Cardiovasc Interv; 2016 Apr; 87(5):951-4. PubMed ID: 26354498
[TBL] [Abstract][Full Text] [Related]
6. Late erosion of Amplatzer septal occluder device resulting in cardiac tamponade.
Tchantchaleishvili V; Melvin AL; Ling FS; Knight PA
Interact Cardiovasc Thorac Surg; 2014 Dec; 19(6):1074-6. PubMed ID: 25183740
[TBL] [Abstract][Full Text] [Related]
7. Intramural atrial haematoma as a complication of the percutaneous atrial septal defect closure.
Lipiec P; Filipiak-Strzecka D; Szymczyk K; Peruga JZ; Kasprzak JD
Eur Heart J Cardiovasc Imaging; 2017 Oct; 18(10):1185. PubMed ID: 28535191
[No Abstract] [Full Text] [Related]
8. Surgical perspective of percutaneous device closure of atrial septal defect.
Thingnam SKS; Mahajan S; Kumar V
Asian Cardiovasc Thorac Ann; 2018 Jun; 26(5):343-346. PubMed ID: 29719981
[TBL] [Abstract][Full Text] [Related]
9. Very late cardiac tamponade following successful transcatheter closure of an atrial septal defect with the Amplatzer septal occluder.
Herren T; Schwanda M; Genoni M; Eberli FR
Clin Res Cardiol; 2015 Jun; 104(6):530-3. PubMed ID: 25720331
[No Abstract] [Full Text] [Related]
10. Late Cardiac Rupture after Amplatzer Septal Occluder Implantation.
Arnaz A; Turkekul Y; Yalcinbas Y; Saygili A; Sarioglu T
Tex Heart Inst J; 2016 Dec; 43(6):541-542. PubMed ID: 28100979
[TBL] [Abstract][Full Text] [Related]
11. An asymptomatic child of pre-perforation erosion after transcatheter closure of atrial septal defect.
Zhang WL; Liang F
J Cardiothorac Surg; 2021 Sep; 16(1):263. PubMed ID: 34537071
[TBL] [Abstract][Full Text] [Related]
12. Cardiac perforation following transcatheter PFO closure.
Trepels T; Zeplin H; Sievert H; Billinger K; Krumsdorf U; Zadan E; Horvath K
Catheter Cardiovasc Interv; 2003 Jan; 58(1):111-3. PubMed ID: 12508211
[TBL] [Abstract][Full Text] [Related]
13. Catheter entrapment around the Chiari network during percutaneous atrial septal defect closure.
Aydın A; Gürol T; Yılmazer MS; Dağdeviren B
Anadolu Kardiyol Derg; 2011 Mar; 11(2):E6-7. PubMed ID: 21362595
[No Abstract] [Full Text] [Related]
14. Cardiac perforation 6 years following the implantation of an Amplatzer septal occluder.
Agematsu K; Okamura T; Takiguchi Y; Harada Y
J Card Surg; 2018 Feb; 33(2):105-106. PubMed ID: 29460301
[No Abstract] [Full Text] [Related]
15. Late cardiac tamponade after transcatheter closure of atrial septal defect with Cardioseal device.
Pinto FF; Sousa L; Fragata J
Cardiol Young; 2001 Mar; 11(2):233-5. PubMed ID: 11293746
[TBL] [Abstract][Full Text] [Related]
16. Iatrogenic Left Atrial Puncture Treated with a Septal Occluder Device.
Ghanem R; Tabrizi NS; Shapeton AD; Musuku SR
J Cardiothorac Vasc Anesth; 2024 Jan; 38(1):239-242. PubMed ID: 37926652
[No Abstract] [Full Text] [Related]
17. Two cases of pericardial tamponade due to nitinol wire fracture of a gore septal occluder.
Kumar P; Orford JL; Tobis JM
Catheter Cardiovasc Interv; 2020 Jul; 96(1):219-224. PubMed ID: 31696617
[TBL] [Abstract][Full Text] [Related]
18. Atrio-aortic erosion caused by Amplatzer Atrial Septal Occluder - a case report.
Kamla CE; Buech J; Doldi PM; Hagl C; Juchem G; Dashkevich A
J Cardiothorac Surg; 2021 Mar; 16(1):36. PubMed ID: 33743762
[TBL] [Abstract][Full Text] [Related]
19. Left Atrial Appendage Closure Device Implantation After Percutaneous Atrial Septal Defect Closure.
Heersink D; Murdoch D; Humphries J; Walters DL
JACC Cardiovasc Interv; 2016 May; 9(10):e95-6. PubMed ID: 27131442
[No Abstract] [Full Text] [Related]
20. Lipomatous Atrial Septal Hypertrophy and Atrial Septal Defect With Rim Deficiency.
Takafuji H; Obunai K; Kato N; Honda M; Watanabe H
JACC Cardiovasc Interv; 2022 Feb; 15(3):e31-e33. PubMed ID: 34838468
[No Abstract] [Full Text] [Related]
[Next] [New Search]