BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

174 related articles for article (PubMed ID: 33594673)

  • 1. Dose calculation in proton therapy using a discovery cross-domain generative adversarial network (DiscoGAN).
    Zhang X; Hu Z; Zhang G; Zhuang Y; Wang Y; Peng H
    Med Phys; 2021 May; 48(5):2646-2660. PubMed ID: 33594673
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Feasibility study of patient-specific dose verification in proton therapy utilizing positron emission tomography (PET) and generative adversarial network (GAN).
    Ma S; Hu Z; Ye K; Zhang X; Wang Y; Peng H
    Med Phys; 2020 Oct; 47(10):5194-5208. PubMed ID: 32772377
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Adaptive step size algorithm to increase efficiency of proton macro Monte Carlo dose calculation.
    Kueng R; Frei D; Volken W; Stuermlin F; M Stampanoni MF; Aebersold DM; Manser P; Fix MK
    Radiat Oncol; 2019 Sep; 14(1):165. PubMed ID: 31500647
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An analytical dose-averaged LET calculation algorithm considering the off-axis LET enhancement by secondary protons for spot-scanning proton therapy.
    Hirayama S; Matsuura T; Ueda H; Fujii Y; Fujii T; Takao S; Miyamoto N; Shimizu S; Fujimoto R; Umegaki K; Shirato H
    Med Phys; 2018 Jul; 45(7):3404-3416. PubMed ID: 29788552
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Fast and accurate dose predictions for novel radiotherapy treatments in heterogeneous phantoms using conditional 3D-UNet generative adversarial networks.
    Mentzel F; Kröninger K; Lerch M; Nackenhorst O; Paino J; Rosenfeld A; Saraswati A; Tsoi AC; Weingarten J; Hagenbuchner M; Guatelli S
    Med Phys; 2022 May; 49(5):3389-3404. PubMed ID: 35184310
    [TBL] [Abstract][Full Text] [Related]  

  • 6. An algorithm to assess the need for clinical Monte Carlo dose calculation for small proton therapy fields based on quantification of tissue heterogeneity.
    Bueno M; Paganetti H; Duch MA; Schuemann J
    Med Phys; 2013 Aug; 40(8):081704. PubMed ID: 23927301
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A pencil beam algorithm for magnetic resonance image-guided proton therapy.
    Padilla-Cabal F; Georg D; Fuchs H
    Med Phys; 2018 May; 45(5):2195-2204. PubMed ID: 29532490
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Modified fast adaptive scatter kernel superposition (mfASKS) correction and its dosimetric impact on CBCT-based proton therapy dose calculation.
    Nomura Y; Xu Q; Peng H; Takao S; Shimizu S; Xing L; Shirato H
    Med Phys; 2020 Jan; 47(1):190-200. PubMed ID: 31661161
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Independent dose verification system with Monte Carlo simulations using TOPAS for passive scattering proton therapy at the National Cancer Center in Korea.
    Shin WG; Testa M; Kim HS; Jeong JH; Lee SB; Kim YJ; Min CH
    Phys Med Biol; 2017 Sep; 62(19):7598-7616. PubMed ID: 28809759
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Millisecond speed deep learning based proton dose calculation with Monte Carlo accuracy.
    Pastor-Serrano O; Perkó Z
    Phys Med Biol; 2022 May; 67(10):. PubMed ID: 35447605
    [No Abstract]   [Full Text] [Related]  

  • 11. Clinical implementation of full Monte Carlo dose calculation in proton beam therapy.
    Paganetti H; Jiang H; Parodi K; Slopsema R; Engelsman M
    Phys Med Biol; 2008 Sep; 53(17):4825-53. PubMed ID: 18701772
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Quantifying the effect of air gap, depth, and range shifter thickness on TPS dosimetric accuracy in superficial PBS proton therapy.
    Shirey RJ; Wu HT
    J Appl Clin Med Phys; 2018 Jan; 19(1):164-173. PubMed ID: 29239528
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Improving CBCT quality to CT level using deep learning with generative adversarial network.
    Zhang Y; Yue N; Su MY; Liu B; Ding Y; Zhou Y; Wang H; Kuang Y; Nie K
    Med Phys; 2021 Jun; 48(6):2816-2826. PubMed ID: 33259647
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Long short-term memory networks for proton dose calculation in highly heterogeneous tissues.
    Neishabouri A; Wahl N; Mairani A; Köthe U; Bangert M
    Med Phys; 2021 Apr; 48(4):1893-1908. PubMed ID: 33332644
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dosimetric evaluation of synthetic CT generated with GANs for MRI-only proton therapy treatment planning of brain tumors.
    Kazemifar S; Barragán Montero AM; Souris K; Rivas ST; Timmerman R; Park YK; Jiang S; Geets X; Sterpin E; Owrangi A
    J Appl Clin Med Phys; 2020 May; 21(5):76-86. PubMed ID: 32216098
    [TBL] [Abstract][Full Text] [Related]  

  • 16. CBCT correction using a cycle-consistent generative adversarial network and unpaired training to enable photon and proton dose calculation.
    Kurz C; Maspero M; Savenije MHF; Landry G; Kamp F; Pinto M; Li M; Parodi K; Belka C; van den Berg CAT
    Phys Med Biol; 2019 Nov; 64(22):225004. PubMed ID: 31610527
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of GATE-RTion (GATE/Geant4) Monte Carlo simulation settings for proton pencil beam scanning quality assurance.
    Winterhalter C; Taylor M; Boersma D; Elia A; Guatelli S; Mackay R; Kirkby K; Maigne L; Ivanchenko V; Resch AF; Sarrut D; Sitch P; Vidal M; Grevillot L; Aitkenhead A
    Med Phys; 2020 Nov; 47(11):5817-5828. PubMed ID: 32967037
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A new approach to integrate GPU-based Monte Carlo simulation into inverse treatment plan optimization for proton therapy.
    Li Y; Tian Z; Song T; Wu Z; Liu Y; Jiang S; Jia X
    Phys Med Biol; 2017 Jan; 62(1):289-305. PubMed ID: 27991456
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Training a deep neural network coping with diversities in abdominal and pelvic images of children and young adults for CBCT-based adaptive proton therapy.
    Uh J; Wang C; Acharya S; Krasin MJ; Hua CH
    Radiother Oncol; 2021 Jul; 160():250-258. PubMed ID: 33992626
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Validation and application of a fast Monte Carlo algorithm for assessing the clinical impact of approximations in analytical dose calculations for pencil beam scanning proton therapy.
    Huang S; Souris K; Li S; Kang M; Barragan Montero AM; Janssens G; Lin A; Garver E; Ainsley C; Taylor P; Xiao Y; Lin L
    Med Phys; 2018 Dec; 45(12):5631-5642. PubMed ID: 30295950
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.