These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

162 related articles for article (PubMed ID: 3359605)

  • 1. Direct determination of selenium in serum by graphite-furnace atomic absorption spectrometry with deuterium background correction and a reduced palladium modifier: age-specific reference ranges.
    Jacobson BE; Lockitch G
    Clin Chem; 1988 Apr; 34(4):709-14. PubMed ID: 3359605
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Direct selenium determination in human whole blood by graphite furnace atomic absorption spectrometry with deuterium correction using a L'vov-platform, a Pd/Mg matrix modification and appropriate dilution.
    Van Cauwenbergh R; Robberecht H; Van Dael P; Deelstra H
    J Trace Elem Electrolytes Health Dis; 1990 Jun; 4(2):127-31. PubMed ID: 2136224
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Direct determination of selenium in human blood serum and plasma by electrothermal atomic absorption spectrometry.
    Gardiner PH; Littlejohn D; Halls DJ; Fell GS
    J Trace Elem Med Biol; 1995 Jul; 9(2):74-81. PubMed ID: 8825979
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Determination of selenium in infant formula and enteral formula by dry ash graphite furnace atomic absorption spectrometry with deuterium background correction.
    Cook KK
    J AOAC Int; 1996; 79(5):1162-6. PubMed ID: 8823924
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Direct determination of selenium in rat blood plasma by Zeeman atomic absorption spectrometry.
    Kabirov KK; Kapetanovic IM; Lyubimov AV
    Chem Biol Interact; 2008 Jan; 171(2):152-8. PubMed ID: 18155186
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparative determination of selenium in the serum of various animal species and humans by means of electrothermal atomic absorption spectrometry.
    Forrer R; Gautschi K; Lutz H
    J Trace Elem Electrolytes Health Dis; 1991 Jun; 5(2):101-13. PubMed ID: 1821708
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Determination of trace selenium in milk cow serum with graphite furnace atomic absorption spectrophotometry].
    Dong YG; Shen HJ
    Guang Pu Xue Yu Guang Pu Fen Xi; 2002 Aug; 22(4):691-2. PubMed ID: 12938403
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Determination of beryllium and selenium in human urine and of selenium in human serum by graphite-furnace atomic absorption spectrophotometry.
    Wang HC; Peng HW; Kuo MS
    Anal Sci; 2001 Apr; 17(4):527-32. PubMed ID: 11990571
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Optimization of a chemical modifier in the determination of selenium by graphite furnace atomic absorption spectrometry and its application to wheat and wheat flour analysis.
    Alexiu V; Vladescu L
    Anal Sci; 2005 Feb; 21(2):137-41. PubMed ID: 15732473
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Determination of selenium in the human brain by graphite furnace atomic absorption spectrometry.
    Ejima A; Watanabe C; Koyama H; Matsuno K; Satoh H
    Biol Trace Elem Res; 1996 Jul; 54(1):9-21. PubMed ID: 8862757
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Direct determination of selenium in human blood plasma and seminal plasma by graphite furnace atomic absorption spectrophotometry and clinical application.
    Lin TH; Tseng WC; Cheng SY
    Biol Trace Elem Res; 1998; 64(1-3):133-49. PubMed ID: 9845468
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Direct determination of selenium in human serum by graphite furnace atomic absorption spectroscopy. Improvements due to oxygen ashing in graphite tube and Zeeman effect background correction.
    Nève J; Molle L
    Acta Pharmacol Toxicol (Copenh); 1986; 59 Suppl 7():606-9. PubMed ID: 3776636
    [No Abstract]   [Full Text] [Related]  

  • 13. Plasma selenium concentration in healthy Japanese children and adults determined by flameless atomic absorption spectrophotometry.
    Hatano S; Nishi Y; Usui T
    J Pediatr Gastroenterol Nutr; 1984 Jun; 3(3):426-31. PubMed ID: 6737188
    [TBL] [Abstract][Full Text] [Related]  

  • 14. GFAAS determination of selenium in infant formulas using a microwave digestion method.
    Alegria A; Barbera R; Farré R; Moreno A
    Nahrung; 1994; 38(4):382-5. PubMed ID: 7935739
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A methodological comparison of hydride and carbon furnace atomic absorption spectroscopy for the determination of selenium in serum.
    Oster O; Prellwitz W
    Clin Chim Acta; 1982 Sep; 124(3):277-91. PubMed ID: 7127843
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Determination of trace selenium in edible fungi with graphite furnace atomic absorption spectroscopy].
    Tie M; Zhang W; Li J; Jing K; Zang SL; Li HW
    Guang Pu Xue Yu Guang Pu Fen Xi; 2006 Jan; 26(1):151-3. PubMed ID: 16827367
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Improved sample preparation for accurate determination of low concentrations of lead in whole blood by graphite furnace analysis.
    Jacobson BE; Lockitch G; Quigley G
    Clin Chem; 1991 Apr; 37(4):515-9. PubMed ID: 2015663
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Selenium and glutathione peroxidase reference values in whole blood and plasma of a reference population living in Valencia, Spain.
    Alegría A; Barberá R; Clemente G; Farré R; García MJ; Lagarda MJ
    J Trace Elem Med Biol; 1996 Dec; 10(4):223-8. PubMed ID: 9021673
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Selenium determination in biological fluids using Zeeman background correction electrothermal atomic absorption spectrometry.
    Campillo N; Viñas P; López-García I; Hernández-Córdoba M
    Anal Biochem; 2000 May; 280(2):195-200. PubMed ID: 10790300
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of isotope dilution mass spectrometry and graphite furnace atomic absorption spectrometry with Zeeman background correction for determination of plasma selenium.
    Lewis SA; Hardison NW; Veillon C
    Anal Chem; 1986 May; 58(6):1272-3. PubMed ID: 3717582
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 9.