BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

139 related articles for article (PubMed ID: 33596744)

  • 1. Algebraic formulas characterizing an alternative to Guyton's graphical analysis relevant for heart failure.
    Stiles TW; Morfin Rodriguez AE; Mohiuddin HS; Lee H; Dalal FA; Fuertes WW; Adams TH; Stewart RH; Quick CM
    Am J Physiol Regul Integr Comp Physiol; 2021 Jun; 320(6):R851-R870. PubMed ID: 33596744
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Understanding Guyton's venous return curves.
    Beard DA; Feigl EO
    Am J Physiol Heart Circ Physiol; 2011 Sep; 301(3):H629-33. PubMed ID: 21666119
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Guyton's venous return curves should be taught at medical schools (complete English translation of Japanese version).
    Sunagawa K
    J Physiol Sci; 2017 Jul; 67(4):447-458. PubMed ID: 28349325
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An interactive simulator to deepen the understanding of Guyton's venous return curve.
    Mamorita N; Takeuchi A; Kamata H
    J Physiol Sci; 2024 Mar; 74(1):21. PubMed ID: 38555424
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Estimated venous return surface and cardiac output curve precisely predicts new hemodynamics after volume change.
    Sugimachi M; Sunagawa K; Uemura K; Kamiya A; Shimizu S; Inagaki M; Shishido T
    Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():5205-8. PubMed ID: 21096038
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Venous return and mean systemic filling pressure: physiology and clinical applications.
    Persichini R; Lai C; Teboul JL; Adda I; Guérin L; Monnet X
    Crit Care; 2022 May; 26(1):150. PubMed ID: 35610620
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Experts consensus on the management of the right heart function in critically ill patients].
    Wang XT; Liu DW; Zhang HM; Long Y; Guan XD; Qiu HB; Yu KJ; Yan J; Zhao H; Tang YQ; Ding X; Ma XC; Du W; Kang Y; Tang B; Ai YH; He HW; Chen DC; Chen H; Chai WZ; Zhou X; Cui N; Wang H; Rui X; Hu ZJ; Li JG; Xu Y; Yang Y; Ouyan B; Lin HY; Li YM; Wan XY; Yang RL; Qin YZ; Chao YG; Xie ZY; Sun RH; He ZY; Wang DF; Huang QQ; Jiang DP; Cao XY; Yu RG; Wang X; Chen XK; Wu JF; Zhang LN; Yin MG; Liu LX; Li SW; Chen ZJ; Luo Z;
    Zhonghua Nei Ke Za Zhi; 2017 Dec; 56(12):962-973. PubMed ID: 29202543
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Clinical review: Guyton--the role of mean circulatory filling pressure and right atrial pressure in controlling cardiac output.
    Henderson WR; Griesdale DE; Walley KR; Sheel AW
    Crit Care; 2010; 14(6):243. PubMed ID: 21144008
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A computational model-based validation of Guyton's analysis of cardiac output and venous return curves.
    Mukkamala R; Cohen RJ; Mark RG
    Comput Cardiol; 2002; 29():561-4. PubMed ID: 14686453
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The obligatory role of the kidney in long-term arterial blood pressure control: extending Guyton's model of the circulation.
    Dorrington KL; Pandit JJ
    Anaesthesia; 2009 Nov; 64(11):1218-28. PubMed ID: 19825058
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Macroscopic two-pump two-vasculature cardiovascular model to support treatment of acute heart failure.
    Sugimachi M; Sunagawa K; Uemura K; Kamiya A; Shimizu S; Inagaki M; Shishido T
    Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():2365-8. PubMed ID: 19965188
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Balance point characterization of interstitial fluid volume regulation.
    Dongaonkar RM; Laine GA; Stewart RH; Quick CM
    Am J Physiol Regul Integr Comp Physiol; 2009 Jul; 297(1):R6-16. PubMed ID: 19420292
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Incorporation of venous resistance in Togawa's four quadrant diagram for Guyton's circulatory equilibrium.
    Suga H
    Jpn Heart J; 1988 Jan; 29(1):89-98. PubMed ID: 3398246
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A simple Computational Model-Based Validation of Guyton's closed circuit analysis of the heart and the peripheral circulatory system.
    Zervides C; Hose DR
    Conf Proc IEEE Eng Med Biol Soc; 2005; 2005():5486-9. PubMed ID: 17281495
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A cardiovascular mathematical model of graded head-up tilt.
    Lim E; Chan GS; Dokos S; Ng SC; Latif LA; Vandenberghe S; Karunanithi M; Lovell NH
    PLoS One; 2013; 8(10):e77357. PubMed ID: 24204817
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Understanding the contribution of Guyton's large circulatory model to long-term control of arterial pressure.
    Montani JP; Van Vliet BN
    Exp Physiol; 2009 Apr; 94(4):382-8. PubMed ID: 19286638
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A novel framework of circulatory equilibrium.
    Uemura K; Sugimachi M; Kawada T; Kamiya A; Jin Y; Kashihara K; Sunagawa K
    Am J Physiol Heart Circ Physiol; 2004 Jun; 286(6):H2376-85. PubMed ID: 14764438
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The pressure-volume relationship of the heart: past, present and future.
    Sunagawa K
    Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():3554-5. PubMed ID: 21096827
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Testing Computer Models Predicting Human Responses to a High-Salt Diet.
    Kurtz TW; DiCarlo SE; Pravenec M; Ježek F; Šilar J; Kofránek J; Morris RC
    Hypertension; 2018 Dec; 72(6):1407-1416. PubMed ID: 30571226
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Computer simulation of haemodynamic parameters changes with left ventricle assist device and mechanical ventilation.
    De Lazzari C; Darowski M; Ferrari G; Clemente F; Guaragno M
    Comput Biol Med; 2000 Mar; 30(2):55-69. PubMed ID: 10714442
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.