These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

116 related articles for article (PubMed ID: 3359782)

  • 1. Dialysis-associated adverse reactions with high-flux membranes and microbial contamination of liquid bicarbonate concentrate.
    Man NK; Ciancioni C; Faivre JM; Diab N; London G; Maret J; Wambergue FP
    Contrib Nephrol; 1988; 62():24-34. PubMed ID: 3359782
    [No Abstract]   [Full Text] [Related]  

  • 2. A prospective study of pyrogenic reactions in hemodialysis patients using bicarbonate dialysis fluids filtered to remove bacteria and endotoxin.
    Pegues DA; Oettinger CW; Bland LA; Oliver JC; Arduino MJ; Aguero SM; McAllister SK; Gordon SM; Favero MS; Jarvis WR
    J Am Soc Nephrol; 1992 Oct; 3(4):1002-7. PubMed ID: 1450362
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Potential bacteriologic and endotoxin hazards associated with liquid bicarbonate concentrate.
    Bland LA; Ridgeway MR; Aguero SM; Carson LA; Favero MS
    ASAIO Trans; 1987; 33(3):542-5. PubMed ID: 3675985
    [No Abstract]   [Full Text] [Related]  

  • 4. [High-efficiency membranes and the dialysis solution].
    Agliata S; Airoldi G; Baroni A; Boschetti M; Schweiger K; Fortina F; Ragazzoni E; Cavagnino A
    Minerva Urol Nefrol; 1990; 42(1):39-42. PubMed ID: 2389221
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Microbiologic contamination of liquid bicarbonate concentrate for hemodialysis.
    Ebben JP; Hirsch DN; Luehmann DA; Collins AJ; Keshaviah PR
    ASAIO Trans; 1987; 33(3):269-73. PubMed ID: 3675952
    [No Abstract]   [Full Text] [Related]  

  • 6. Bacteria and endotoxin removal from bicarbonate dialysis fluids for use in conventional, high-efficiency, and high-flux hemodialysis.
    Oliver JC; Bland LA; Oettinger CW; Arduino MJ; Garrard M; Pegues DA; McAllister S; Moone T; Aguero S; Favero MS
    Artif Organs; 1992 Apr; 16(2):141-5. PubMed ID: 10078235
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Defining the microbiological quality of dialysis fluid.
    Ledebo I; Nystrand R
    Artif Organs; 1999 Jan; 23(1):37-43. PubMed ID: 9950177
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Culture of dialysis fluids on nutrient-rich media for short periods at elevated temperatures underestimate microbial contamination.
    Pass T; Wright R; Sharp B; Harding GB
    Blood Purif; 1996; 14(2):136-45. PubMed ID: 8785029
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Chronic haemodialysis with bicarbonate dialysate. Technical and clinical aspects.
    Leunissen KM; Claessens PJ; Mooy JM; van Hooff JP; Shaldon S
    Blood Purif; 1990; 8(6):347-58. PubMed ID: 2093332
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Microbiological and endotoxin assays of hemodialysis fluids.
    Bland LA
    Adv Ren Replace Ther; 1995 Jan; 2(1):70-9. PubMed ID: 7614339
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Contamination of dialysis water and dialysate. A survey of 30 centers.
    Bambauer R; Schauer M; Jung WK; Daum V; Vienken J
    ASAIO J; 1994; 40(4):1012-6. PubMed ID: 7858320
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effects of incubation time and temperature on microbiologic sampling procedures for hemodialysis fluids.
    Arduino MJ; Bland LA; Aguero SM; Favero MS
    J Clin Microbiol; 1991 Jul; 29(7):1462-5. PubMed ID: 1885742
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [A study on the endotoxin and bacterial contamination in reverse osmosis water and dialysis fluids].
    Liu H; Li G; Zhang X; Duan X; Yao Y
    Zhonghua Nei Ke Za Zhi; 1999 Dec; 38(12):806-9. PubMed ID: 11798721
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Mystery solved? Halomonas and dialysis infections.
    Stevens DA; Johnson N
    Diagn Microbiol Infect Dis; 2017 May; 88(1):1-2. PubMed ID: 28274500
    [No Abstract]   [Full Text] [Related]  

  • 15. Why and how to monitor bacterial contamination of dialysate?
    Pérez-García R; Rodríguez-Benítez PO
    Nephrol Dial Transplant; 2000 Jun; 15(6):760-4. PubMed ID: 10831624
    [No Abstract]   [Full Text] [Related]  

  • 16. [Hypersensitivity reactions during hemodialysis. Role of high permeability, retrofiltration and bacterial contamination of the dialysate].
    Montagnac R; Schillinger F; Milcent T; Croix JC
    Nephrologie; 1988; 9(1):29-32. PubMed ID: 3134622
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Sterile filtration of dialysate: is it really of no use?
    Bommer J
    Nephrol Dial Transplant; 2001 Oct; 16(10):1992-4. PubMed ID: 11572885
    [No Abstract]   [Full Text] [Related]  

  • 18. Chlorine dioxide: a new agent for dialysis monitor disinfection in a pediatric center.
    Palo TD; Atti M; Bellantuono R; Giordano M; Caringella DA
    Blood Purif; 1997; 15(3):188-94. PubMed ID: 9262845
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Microbial and endotoxin contamination in water and dialysate in the central United States.
    Klein E; Pass T; Harding GB; Wright R; Million C
    Artif Organs; 1990 Apr; 14(2):85-94. PubMed ID: 2350260
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Clinical experience with a new hemodiafiltration (HDF) system.
    Rindi P; Pilone N; Riccò V; Cioni L
    ASAIO Trans; 1988; 34(3):765-8. PubMed ID: 3196595
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.