These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 33603139)

  • 1. An LDV based method to quantify the error of PC-MRI derived Wall Shear Stress measurement.
    Castagna M; Levilly S; Paul-Gilloteaux P; Moussaoui S; Rousset JM; Bonnefoy F; Idier J; Serfaty JM; Le Touzé D
    Sci Rep; 2021 Feb; 11(1):4112. PubMed ID: 33603139
    [TBL] [Abstract][Full Text] [Related]  

  • 2. MR-based wall shear stress measurements in fully developed turbulent flow using the Clauser plot method.
    Shokina N; Bauer A; Teschner G; Buchenberg WB; Tropea C; Egger H; Hennig J; Krafft AJ
    J Magn Reson; 2019 Aug; 305():16-21. PubMed ID: 31158791
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Novel and facile criterion to assess the accuracy of WSS estimation by 4D flow MRI.
    Ko S; Yang B; Cho JH; Lee J; Song S
    Med Image Anal; 2019 Apr; 53():95-103. PubMed ID: 30743192
    [TBL] [Abstract][Full Text] [Related]  

  • 4. WSSNet: Aortic Wall Shear Stress Estimation Using Deep Learning on 4D Flow MRI.
    Ferdian E; Dubowitz DJ; Mauger CA; Wang A; Young AA
    Front Cardiovasc Med; 2021; 8():769927. PubMed ID: 35141290
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Wall shear stress estimation in the aorta: Impact of wall motion, spatiotemporal resolution, and phase noise.
    Zimmermann J; Demedts D; Mirzaee H; Ewert P; Stern H; Meierhofer C; Menze B; Hennemuth A
    J Magn Reson Imaging; 2018 Apr; ():. PubMed ID: 29607574
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The impact of 4D flow displacement artifacts on wall shear stress estimation.
    Schmidt S; Flassbeck S; Schmelter S; Schmeyer E; Ladd ME; Schmitter S
    Magn Reson Med; 2021 Jun; 85(6):3154-3168. PubMed ID: 33421221
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Reproducibility and interobserver variability of systolic blood flow velocity and 3D wall shear stress derived from 4D flow MRI in the healthy aorta.
    van Ooij P; Powell AL; Potters WV; Carr JC; Markl M; Barker AJ
    J Magn Reson Imaging; 2016 Jan; 43(1):236-48. PubMed ID: 26140480
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An In Vitro Hemodynamic Flow System to Study the Effects of Quantified Shear Stresses on Endothelial Cells.
    Avari H; Savory E; Rogers KA
    Cardiovasc Eng Technol; 2016 Mar; 7(1):44-57. PubMed ID: 26621672
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Toward an accurate estimation of wall shear stress from 4D flow magnetic resonance downstream of a severe stenosis.
    Corso P; Walheim J; Dillinger H; Giannakopoulos G; Gülan U; Frouzakis CE; Kozerke S; Holzner M
    Magn Reson Med; 2021 Sep; 86(3):1531-1543. PubMed ID: 33914962
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A comparison of 4D flow MRI-derived wall shear stress with computational fluid dynamics methods for intracranial aneurysms and carotid bifurcations - A review.
    Szajer J; Ho-Shon K
    Magn Reson Imaging; 2018 May; 48():62-69. PubMed ID: 29223732
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Measurements of wall shear stress and aortic pulse wave velocity in swine with familial hypercholesterolemia.
    Wentland AL; Wieben O; Shanmuganayagam D; Krueger CG; Meudt JJ; Consigny D; Rivera L; McBride PE; Reed JD; Grist TM
    J Magn Reson Imaging; 2015 May; 41(5):1475-85. PubMed ID: 24964097
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Observation of intracranial artery and venous sinus hemodynamics using compressed sensing-accelerated 4D flow MRI: performance at different acceleration factors.
    Cao J; Yuan C; Zhang Y; Quan Y; Chang P; Yang J; Song Q; Miao Y
    Front Neurosci; 2024; 18():1438003. PubMed ID: 39119457
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Volumetric segmentation-free method for rapid visualization of vascular wall shear stress using 4D flow MRI.
    Masutani EM; Contijoch F; Kyubwa E; Cheng J; Alley MT; Vasanawala S; Hsiao A
    Magn Reson Med; 2018 Aug; 80(2):748-755. PubMed ID: 29516632
    [TBL] [Abstract][Full Text] [Related]  

  • 14. 3D Quantification of Wall Shear Stress and Oscillatory Shear Index Using a Finite-Element Method in 3D CINE PC-MRI Data of the Thoracic Aorta.
    Sotelo J; Urbina J; Valverde I; Tejos C; Irarrazaval P; Andia ME; Uribe S; Hurtado DE
    IEEE Trans Med Imaging; 2016 Jun; 35(6):1475-87. PubMed ID: 26780787
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Volumetric arterial wall shear stress calculation based on cine phase contrast MRI.
    Potters WV; van Ooij P; Marquering H; vanBavel E; Nederveen AJ
    J Magn Reson Imaging; 2015 Feb; 41(2):505-16. PubMed ID: 24436246
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Quantitative 2D and 3D phase contrast MRI: optimized analysis of blood flow and vessel wall parameters.
    Stalder AF; Russe MF; Frydrychowicz A; Bock J; Hennig J; Markl M
    Magn Reson Med; 2008 Nov; 60(5):1218-31. PubMed ID: 18956416
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The Effect of Spatial and Temporal Resolution of Cine Phase Contrast MRI on Wall Shear Stress and Oscillatory Shear Index Assessment.
    Cibis M; Potters WV; Gijsen FJ; Marquering H; van Ooij P; vanBavel E; Wentzel JJ; Nederveen AJ
    PLoS One; 2016; 11(9):e0163316. PubMed ID: 27669568
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Wall shear stress estimated with phase contrast MRI in an in vitro and in vivo intracranial aneurysm.
    van Ooij P; Potters WV; Guédon A; Schneiders JJ; Marquering HA; Majoie CB; vanBavel E; Nederveen AJ
    J Magn Reson Imaging; 2013 Oct; 38(4):876-84. PubMed ID: 23417769
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Fluid-induced wall shear stress in anthropomorphic brain aneurysm models: MR phase-contrast study at 3 T.
    Ahn S; Shin D; Tateshima S; Tanishita K; Vinuela F; Sinha S
    J Magn Reson Imaging; 2007 Jun; 25(6):1120-30. PubMed ID: 17520716
    [TBL] [Abstract][Full Text] [Related]  

  • 20. 3D axial and circumferential wall shear stress from 4D flow MRI data using a finite element method and a laplacian approach.
    Sotelo J; Dux-Santoy L; Guala A; Rodríguez-Palomares J; Evangelista A; Sing-Long C; Urbina J; Mura J; Hurtado DE; Uribe S
    Magn Reson Med; 2018 May; 79(5):2816-2823. PubMed ID: 28980342
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.