These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. Intraoperative three-dimensional transesophageal echocardiography for assessing the defect geometries of mitral prosthetic paravalvular leak during transcatheter closure. Wei J; Yin WH; Lee YT; Hsiung MC; Tsai SK; Chuang YC; Ou CH; Chou YP J Chin Med Assoc; 2015 Mar; 78(3):158-63. PubMed ID: 25467793 [TBL] [Abstract][Full Text] [Related]
4. Percutaneous closure of a large aortic paravalvular leak using two duct occluder devices. Sasikumar N; Rajasekar P; Suramanyan R Indian Heart J; 2013; 65(3):283-5. PubMed ID: 23809382 [TBL] [Abstract][Full Text] [Related]
5. Evaluation of endothelialization after percutaneous closure of paravalvular leaks. Ozkan M; Astarcıoğlu MA; Gürsoy MO J Invasive Cardiol; 2012 Apr; 24(4):E72-4. PubMed ID: 22477761 [TBL] [Abstract][Full Text] [Related]
6. Percutaneous Paravalvular Leak Closure Early Post-MV Replacement With Retrieval of Embolized Muscular VSD Device. Abuelatta R; Naeim HA JACC Case Rep; 2019 Dec; 1(4):471-476. PubMed ID: 34316859 [TBL] [Abstract][Full Text] [Related]
7. Clinical outcomes in patients undergoing percutaneous closure of periprosthetic paravalvular leaks. Ruiz CE; Jelnin V; Kronzon I; Dudiy Y; Del Valle-Fernandez R; Einhorn BN; Chiam PT; Martinez C; Eiros R; Roubin G; Cohen HA J Am Coll Cardiol; 2011 Nov; 58(21):2210-7. PubMed ID: 22078427 [TBL] [Abstract][Full Text] [Related]
8. Embolization of Two Occluder Devices Following Device Closure of Acute Postoperative Mitral Paravalvular Leak. Sivakumar K; Singhi AK J Cardiovasc Imaging; 2021 Apr; 29(2):183-186. PubMed ID: 33605093 [No Abstract] [Full Text] [Related]
9. Paravalvular leak closure with two large size devices. Trehan VK; Subhendu MS; Chaturvedi V; Pandit BN; Goyal M Indian Heart J; 2014; 66(1):91-4. PubMed ID: 24581103 [TBL] [Abstract][Full Text] [Related]
10. Percutaneous transapical closure of cardiac apex with an ADO-II device after successful transapical transcatheter prosthetic mitral paravalvular leak closure. Iyisoy A; Ozturk C; Celik T; Demirkol S; Cingoz F; Unlu M; Arslan Z Int J Cardiol; 2015; 189():289-92. PubMed ID: 25917979 [No Abstract] [Full Text] [Related]
11. Paravalvular mitral regurgitation treated with an amplatzer septal occluder device: a case report and review of the literature. Momplaisir T; Matthews RV J Invasive Cardiol; 2007 Feb; 19(2):E46-50. PubMed ID: 17268052 [TBL] [Abstract][Full Text] [Related]
12. Surgical Transapical Approach for Prosthetic Mitral Paravalvular Leak Closure: Early Results. Aydin U; Sen O; Kadirogullari E; Onan B; Yildirim A; Bakir I Artif Organs; 2017 Mar; 41(3):253-261. PubMed ID: 27862027 [TBL] [Abstract][Full Text] [Related]