These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
186 related articles for article (PubMed ID: 3360523)
41. In vitro velocity and turbulence measurements in the vicinity of three new mechanical aortic heart valve prostheses: Björk-Shiley Monostrut, Omni-Carbon, and Duromedics. Yoganathan AP; Sung HW; Woo YR; Jones M J Thorac Cardiovasc Surg; 1988 May; 95(5):929-39. PubMed ID: 3361941 [TBL] [Abstract][Full Text] [Related]
42. Variability of regurgitation in Björk-Shiley mitral valves and relationship to disc occluder design: an in vitro two-dimensional color-Doppler flow mapping study. Lindower PD; Dellsperger KC; Johnson B; Chandran KB; Vandenberg BF J Heart Valve Dis; 1996 Aug; 5 Suppl 2():S178-83. PubMed ID: 8905518 [TBL] [Abstract][Full Text] [Related]
43. Color Doppler regurgitant characteristics of normal mechanical mitral valve prostheses in vitro. Baumgartner H; Khan S; DeRobertis M; Czer L; Maurer G Circulation; 1992 Jan; 85(1):323-32. PubMed ID: 1728464 [TBL] [Abstract][Full Text] [Related]
44. [Doppler echocardiographic evaluation of the new mechanical bileaflet Sorin Bicarbon valve prosthesis compared with St. Jude Medical]. Badano L; Carratino L; De Gaetano G; Piazza R; Calisi P; Passerone G; Lucatti A G Ital Cardiol; 1994 Jun; 24(6):733-43. PubMed ID: 8088472 [TBL] [Abstract][Full Text] [Related]
45. Auscultatory characteristics of normally functioning Lillehei-Kaster, Björk-Shiley, and St Jude heart valve prostheses. Kupari M; Harjula A; Mattila S Br Heart J; 1986 Apr; 55(4):364-70. PubMed ID: 3964503 [TBL] [Abstract][Full Text] [Related]
46. Mitral valve replacement. A comparative clinical and haemodynamic study of the new Lillehei-Kaster and Björk-Shiley prostheses. Nitter-Hauge S; Hall KV; Froysaker T Scand J Thorac Cardiovasc Surg; 1977; 11(2):111-7. PubMed ID: 897617 [TBL] [Abstract][Full Text] [Related]
47. Experience with surgery of the heart valves. Björk VO Ann Chir Gynaecol; 1976; 65(2):75-81. PubMed ID: 962282 [TBL] [Abstract][Full Text] [Related]
48. Echocardiographic assessment of the Hall Kaster mitral prosthesis. Wong PH; Mok CK Aust N Z J Surg; 1982 Dec; 52(6):554-7. PubMed ID: 6962722 [TBL] [Abstract][Full Text] [Related]
49. Effect of prosthetic aortic valve design on the Doppler-catheter gradient correlation: an in vitro study of normal St. Jude, Medtronic-Hall, Starr-Edwards and Hancock valves. Baumgartner H; Khan S; DeRobertis M; Czer L; Maurer G J Am Coll Cardiol; 1992 Feb; 19(2):324-32. PubMed ID: 1531058 [TBL] [Abstract][Full Text] [Related]
50. Intravascular haemolysis after valve replacement: comparative study between Starr-Edwards (ball valve) and Björk-Shiley (disc valve) prosthesis. Falk RH; Mackinnon J; Wainscoat J; Melikian V; Bignell AH Thorax; 1979 Dec; 34(6):746-8. PubMed ID: 542913 [TBL] [Abstract][Full Text] [Related]
51. [A Doppler echocardiographic study of normal and dysfunctioning Carpentier-Edwards bioprostheses]. Bonaduce D; Breglio R; Conforti G; Montemurro MV; Petretta M; Covino E; Morgano G; Bianchi V G Ital Cardiol; 1990 Jan; 20(1):50-7. PubMed ID: 2328859 [TBL] [Abstract][Full Text] [Related]
52. Excellence and Durability: A Normally Functioning Björk-Shiley Flat-Disc Prosthesis 42 Years Post Implantation. Shaikh A; Jamil Tajik A J Heart Valve Dis; 2016 Mar; 25(2):237-239. PubMed ID: 27989074 [TBL] [Abstract][Full Text] [Related]
53. Limitations of Doppler ultrasound in the assessment of the function of prosthetic mitral valves. Chambers J; Jackson G; Jewitt D Br Heart J; 1990 Mar; 63(3):189-94. PubMed ID: 2183860 [TBL] [Abstract][Full Text] [Related]
54. [Functional transvalvular regurgitation in patients with Björk-Shiley aortic valves: a pulsed Doppler echocardiographic study]. Yoshida K; Yoshikawa J; Kato H; Yanagihara K; Okumachi F; Koizumi K; Shiratori K; Asaka T; Suzuki K; Inanami H J Cardiogr; 1985 Dec; 15(4):1137-44. PubMed ID: 3841896 [TBL] [Abstract][Full Text] [Related]
55. [Mitral prostheses with and without dysfunction: evaluation using 2-D Doppler echocardiography]. Bernardes L; Abreu J; Soares R; Matos P; Ramos JS; Salomão S Rev Port Cardiol; 1990 Dec; 9(12):973-9. PubMed ID: 2093337 [TBL] [Abstract][Full Text] [Related]
56. Obstructic characteristics of Björk-Shiley, Hancock, and Lillehei-Kaster prosthetic mitral valves in the immediate postoperative period. Holen J; Hìe J; Semb B Acta Med Scand; 1978; 204(1-2):5-10. PubMed ID: 685731 [TBL] [Abstract][Full Text] [Related]
57. Doppler-derived pressure differences in normally functioning aortic valve prostheses. Studies in Björk-Shiley monostrut and Biocor porcine prostheses. Eriksson M; Brodin LA; Ericsson A; Lindblom D Scand J Thorac Cardiovasc Surg; 1993; 27(2):93-7. PubMed ID: 8211011 [TBL] [Abstract][Full Text] [Related]
58. Echocardiographic description of the CarboMedics bileaflet prosthetic heart valve. Chambers J; Cross J; Deverall P; Sowton E J Am Coll Cardiol; 1993 Feb; 21(2):398-405. PubMed ID: 8426004 [TBL] [Abstract][Full Text] [Related]
59. Doppler evaluation of bioprosthetic and mechanical aortic valves: data from four models in 107 stable, ambulatory patients. Ramirez ML; Wong M; Sadler N; Shah PM Am Heart J; 1988 Feb; 115(2):418-25. PubMed ID: 3341177 [TBL] [Abstract][Full Text] [Related]
60. Chronic haemolysis following combined mitral and aortic valve replacement. A randomized study between the Björk-Shiley and Lillehei-Kaster disc valve prostheses. Nitter-Hauge S Scand J Thorac Cardiovasc Surg; 1979; 13(2):97-101. PubMed ID: 472679 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]