These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
177 related articles for article (PubMed ID: 33620530)
1. Pros and cons of navigated versus conventional total knee arthroplasty-a retrospective analysis of over 2400 patients. Meyer M; Renkawitz T; Völlner F; Benditz A; Grifka J; Weber M Arch Orthop Trauma Surg; 2021 Nov; 141(11):1983-1991. PubMed ID: 33620530 [TBL] [Abstract][Full Text] [Related]
2. No advantage with navigated versus conventional mechanically aligned total knee arthroplasty-10 year results of a randomised controlled trial. Farhan-Alanie OM; Altell T; O'Donnell S; May P; Doonan J; Rowe P; Jones B; Blyth MJG Knee Surg Sports Traumatol Arthrosc; 2023 Mar; 31(3):751-759. PubMed ID: 36166095 [TBL] [Abstract][Full Text] [Related]
3. Imageless robotic-assisted total knee arthroplasty leads to similar 24-month WOMAC scores as compared to conventional total knee arthroplasty: a retrospective cohort study. Held MB; Gazgalis A; Neuwirth AL; Shah RP; Cooper HJ; Geller JA Knee Surg Sports Traumatol Arthrosc; 2022 Aug; 30(8):2631-2638. PubMed ID: 33961067 [TBL] [Abstract][Full Text] [Related]
4. Computer navigation for total knee arthroplasty achieves better postoperative alignment compared to conventional and patient-specific instrumentation in a low-volume setting. Suero EM; Lueke U; Stuebig T; Hawi N; Krettek C; Liodakis E Orthop Traumatol Surg Res; 2018 Nov; 104(7):971-975. PubMed ID: 29704634 [TBL] [Abstract][Full Text] [Related]
5. Surgical training does not affect operative time and outcome in total knee arthroplasty. Weber M; Worlicek M; Voellner F; Woerner M; Benditz A; Weber D; Grifka J; Renkawitz T PLoS One; 2018; 13(6):e0197850. PubMed ID: 29856769 [TBL] [Abstract][Full Text] [Related]
6. Current state of computer navigation and robotics in unicompartmental and total knee arthroplasty: a systematic review with meta-analysis. van der List JP; Chawla H; Joskowicz L; Pearle AD Knee Surg Sports Traumatol Arthrosc; 2016 Nov; 24(11):3482-3495. PubMed ID: 27600634 [TBL] [Abstract][Full Text] [Related]
7. 2017 Chitranjan S. Ranawat Award: Does Computer Navigation in Knee Arthroplasty Improve Functional Outcomes in Young Patients? A Randomized Study. Kim YH; Park JW; Kim JS Clin Orthop Relat Res; 2018 Jan; 476(1):6-15. PubMed ID: 29389753 [TBL] [Abstract][Full Text] [Related]
8. Restoration of constitutional alignment optimizes outcomes of computer navigated total knee arthroplasty: a prospective randomized controlled trial. Zheng K; Wang Y; Wang T; Zhu F; Zhang L; Li R; Zhou J; Geng D; Xu Y Int Orthop; 2024 Apr; 48(4):971-981. PubMed ID: 38289379 [TBL] [Abstract][Full Text] [Related]
9. No differences in mid- to long-term outcomes of computer-assisted navigation versus conventional total knee arthroplasty. Lee DY; Park YJ; Hwang SC; Park JS; Kang DG Knee Surg Sports Traumatol Arthrosc; 2020 Oct; 28(10):3183-3192. PubMed ID: 31784782 [TBL] [Abstract][Full Text] [Related]
10. Clinical, radiological and survivorship results after ten years comparing navigated and conventional total knee arthroplasty: a matched-pair analysis. Baier C; Wolfsteiner J; Otto F; Zeman F; Renkawitz T; Springorum HR; Maderbacher G; Grifka J Int Orthop; 2017 Oct; 41(10):2037-2044. PubMed ID: 28550426 [TBL] [Abstract][Full Text] [Related]
11. Population-based Survivorship of Computer-navigated Versus Conventional Total Knee Arthroplasty. Antonios JK; Kang HP; Robertson D; Oakes DA; Lieberman JR; Heckmann ND J Am Acad Orthop Surg; 2020 Oct; 28(20):857-864. PubMed ID: 31934926 [TBL] [Abstract][Full Text] [Related]
12. Accelerometer-Based Navigation versus Conventional Total Knee Arthroplasty for Posttraumatic Knee Osteoarthritis. Rattanaprichavej P; Laoruengthana A Clin Orthop Surg; 2022 Dec; 14(4):522-529. PubMed ID: 36518940 [TBL] [Abstract][Full Text] [Related]
13. Computer navigation and total knee arthroplasty. Shi J; Wei Y; Wang S; Chen F; Wu J; Huang G; Chen J; Wei L; Xia J Orthopedics; 2014 Jan; 37(1):e39-43. PubMed ID: 24683655 [TBL] [Abstract][Full Text] [Related]
14. A new robotically assisted technique can improve outcomes of total knee arthroplasty comparing to an imageless navigation system. Mancino F; Rossi SMP; Sangaletti R; Lucenti L; Terragnoli F; Benazzo F Arch Orthop Trauma Surg; 2023 May; 143(5):2701-2711. PubMed ID: 35913518 [TBL] [Abstract][Full Text] [Related]
15. Small improvements in mechanical axis alignment achieved with MRI versus CT-based patient-specific instruments in TKA: a randomized clinical trial. Pfitzner T; Abdel MP; von Roth P; Perka C; Hommel H Clin Orthop Relat Res; 2014 Oct; 472(10):2913-22. PubMed ID: 25024031 [TBL] [Abstract][Full Text] [Related]
16. Joint line changes after primary total knee arthroplasty: navigated versus non-navigated. Jawhar A; Shah V; Sohoni S; Scharf HP Knee Surg Sports Traumatol Arthrosc; 2013 Oct; 21(10):2355-62. PubMed ID: 23794005 [TBL] [Abstract][Full Text] [Related]
17. Alignment in total knee arthroplasty - A comparison of patient-specific implants with the conventional technique. Arbab D; Reimann P; Brucker M; Bouillon B; Lüring C Knee; 2018 Oct; 25(5):882-887. PubMed ID: 29936030 [TBL] [Abstract][Full Text] [Related]
19. Computer-navigated minimally invasive total knee arthroplasty for patients with retained implants in the femur. Lin SY; Chen CH; Huang PJ; Fu YC; Huang HT Kaohsiung J Med Sci; 2014 Aug; 30(8):415-21. PubMed ID: 25002380 [TBL] [Abstract][Full Text] [Related]
20. Comparison of computer-navigated and conventional total knee arthroplasty in patients with Ranawat type-II valgus deformity: medium-term clinical and radiological results. Huang TW; Lee CY; Lin SJ; Peng KT; Huang KC; Lee MS; Hsu RW; Shen WJ BMC Musculoskelet Disord; 2014 Nov; 15():390. PubMed ID: 25416446 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]