These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

251 related articles for article (PubMed ID: 33625608)

  • 21. Efficacy of low-dose cone beam computed tomography and metal artifact reduction tool for assessment of peri-implant bone defects: an in vitro study.
    Nomier AS; Gaweesh YSE; Taalab MR; El Sadat SA
    BMC Oral Health; 2022 Dec; 22(1):615. PubMed ID: 36528573
    [TBL] [Abstract][Full Text] [Related]  

  • 22. In vitro assessment of artifacts induced by titanium dental implants in cone beam computed tomography.
    Benic GI; Sancho-Puchades M; Jung RE; Deyhle H; Hämmerle CH
    Clin Oral Implants Res; 2013 Apr; 24(4):378-83. PubMed ID: 23106603
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Evaluation of artifacts generated by titanium, zirconium, and titanium-zirconium alloy dental implants on MRI, CT, and CBCT images: A phantom study.
    Demirturk Kocasarac H; Ustaoglu G; Bayrak S; Katkar R; Geha H; Deahl ST; Mealey BL; Danaci M; Noujeim M
    Oral Surg Oral Med Oral Pathol Oral Radiol; 2019 Jun; 127(6):535-544. PubMed ID: 30879914
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Evaluation of a metal artifact reduction algorithm and an adaptive image noise optimization filter in the estimation of peri-implant fenestration defects using cone beam computed tomography: an in-vitro study.
    Bagis N; Kurt MH; Evli C; Camgoz M; Atakan C; Peker Ozturk H; Orhan K
    Oral Radiol; 2022 Jul; 38(3):325-335. PubMed ID: 34387842
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Measurement Accuracy in Cone Beam Computed Tomography in the Presence of Metal Artifact.
    Ismail A; Lakschevitz F; MacDonald D; Ford NL
    Int J Oral Maxillofac Implants; 2022; 37(1):143-152. PubMed ID: 35235633
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Metal artifact reduction using iterative CBCT reconstruction algorithm for head and neck radiation therapy: A phantom and clinical study.
    Washio H; Ohira S; Funama Y; Morimoto M; Wada K; Yagi M; Shimamoto H; Koike Y; Ueda Y; Karino T; Inui S; Nitta Y; Miyazaki M; Teshima T
    Eur J Radiol; 2020 Nov; 132():109293. PubMed ID: 32987251
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Application of an auto-edge counting method for quantification of metal artifacts in CBCT images: a multivariate analysis of object position, field of view size, tube voltage, and metal artifact reduction algorithm.
    Khosravifard A; Saberi BV; Khosravifard N; Motallebi S; Kajan ZD; Ghaffari ME
    Oral Surg Oral Med Oral Pathol Oral Radiol; 2021 Dec; 132(6):735-743. PubMed ID: 33975812
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Diagnosis of external root resorption in teeth close and distant to zirconium implants: influence of acquisition parameters and artefacts produced during cone beam computed tomography.
    Freitas DQ; Nascimento EHL; Vasconcelos TV; Noujeim M
    Int Endod J; 2019 Jun; 52(6):866-873. PubMed ID: 30585641
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Artifacts caused by titanium implants in CBCT images of the mandible: an experimental study.
    Fardim KAC; Machado AH; Assis NMSP; Sotto-Maior BS; Mauad LQ; Devito KL
    Gen Dent; 2022; 70(1):72-77. PubMed ID: 34978995
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Evaluation of Cone-beam Computed Tomography Artifacts Produced by Metal Objects Located Within and Outside the Field of View.
    Kassabji A; Tahmasbi M; Augsburger RA; Nair M; Kesterke MJ; Jalali P
    J Endod; 2022 Feb; 48(2):249-254. PubMed ID: 34890593
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Effect of metal artefact reduction level on the assessment of dental implant positioning by cone-beam computed tomography.
    Capel CP; da Motta RJG; Pauwels R; Gaêta-Araujo H; Oliveira-Santos C; Tirapelli C
    Dentomaxillofac Radiol; 2024 Apr; 53(4):233-239. PubMed ID: 38466923
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Magnitude of beam-hardening artifacts produced by gutta-percha and metal posts on cone-beam computed tomography with varying tube current.
    Gaêta-Araujo H; Nascimento EHL; Fontenele RC; Mancini AXM; Freitas DQ; Oliveira-Santos C
    Imaging Sci Dent; 2020 Mar; 50(1):1-7. PubMed ID: 32206614
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Influence of metal artefact reduction on the diagnosis of contact between implant and mandibular canal in cone beam computed tomography: An ex-vivo study.
    de Freitas BN; da Motta RJG; Pauwels R; Oliveira-Santos C; Tirapelli C
    Clin Oral Implants Res; 2023 Jul; 34(7):741-750. PubMed ID: 37246310
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Observer Evaluation of a Metal Artifact Reduction Algorithm Applied to Head and Neck Cone Beam Computed Tomographic Images.
    Korpics M; Surucu M; Mescioglu I; Alite F; Block AM; Choi M; Emami B; Harkenrider MM; Solanki AA; Roeske JC
    Int J Radiat Oncol Biol Phys; 2016 Nov; 96(4):897-904. PubMed ID: 27788959
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Mapping artifacts generated in a tooth adjacent to titanium and zirconia implants located in the endomass and exomass in cone beam computed tomography: an ex vivo study.
    Andrade-Bortoletto MFS; Fontenele RC; Farias-Gomes A; Freitas DQ
    Oral Surg Oral Med Oral Pathol Oral Radiol; 2024 Jan; 137(1):73-82. PubMed ID: 37838553
    [TBL] [Abstract][Full Text] [Related]  

  • 36. b-MAR: bidirectional artifact representations learning framework for metal artifact reduction in dental CBCT.
    Song Y; Yao T; Peng S; Zhu M; Meng M; Ma J; Zeng D; Huang J; Bian Z; Wang Y
    Phys Med Biol; 2024 Jul; 69(14):. PubMed ID: 38588680
    [No Abstract]   [Full Text] [Related]  

  • 37. The Effect of Implant-Induced Artifacts on Interpreting Adjacent Bone Structures on Cone-Beam Computed Tomography Scans.
    Sheridan RA; Chiang YC; Decker AM; Sutthiboonyapan P; Chan HL; Wang HL
    Implant Dent; 2018 Feb; 27(1):10-14. PubMed ID: 29095787
    [TBL] [Abstract][Full Text] [Related]  

  • 38. The influence of metal artifact reduction on the trueness of registration of a cone-beam computed tomography scan with an intraoral scan in the presence of severe restoration artifact.
    Biun J; Dudhia R; Arora H
    J Prosthodont; 2024 Aug; 33(7):700-705. PubMed ID: 37691179
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Effect of exposure parameters of cone beam computed tomography on metal artifact reduction around the dental implants in various bone densities.
    Shokri A; Jamalpour MR; Khavid A; Mohseni Z; Sadeghi M
    BMC Med Imaging; 2019 Apr; 19(1):34. PubMed ID: 31035955
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Influence of kilovoltage-peak and the metal artifact reduction tool in cone-beam computed tomography on the detection of bone defects around titanium-zirconia and zirconia implants.
    Fontenele RC; Nascimento EHL; Imbelloni-Vasconcelos AC; Martins LAC; Pontual ADA; Ramos-Perez FMM; Freitas DQ
    Imaging Sci Dent; 2022 Sep; 52(3):267-273. PubMed ID: 36238703
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 13.