136 related articles for article (PubMed ID: 33629597)
1. Fatigue Resistance of the Advanta V12/iCast and Viabahn Balloon-Expandable Stent-Graft as Bridging Stents in Experimental Fenestrated Endografting.
Torsello G; Müller M; Litterscheid S; Berekoven B; Austermann M; Torsello GF
J Endovasc Ther; 2021 Jun; 28(3):463-468. PubMed ID: 33629597
[TBL] [Abstract][Full Text] [Related]
2. Comparison of the Biomechanical Properties of the Advanta V12/iCast and Viabahn Stent-Grafts as Bridging Devices in Fenestrated Endografts: An In Vitro Study.
Torsello GF; Herten M; Müller M; Frank A; Torsello GB; Austermann M
J Endovasc Ther; 2020 Apr; 27(2):258-265. PubMed ID: 32096435
[No Abstract] [Full Text] [Related]
3. In Vitro Evaluation of the Gore Viabahn Balloon-Expandable Stent-Graft for Fenestrated Endovascular Aortic Repair.
Torsello GF; Herten M; Müller M; Frank A; Torsello GB; Austermann M
J Endovasc Ther; 2019 Jun; 26(3):361-368. PubMed ID: 30975017
[TBL] [Abstract][Full Text] [Related]
4. Outcomes of bridging stent grafts in fenestrated and branched endovascular aortic repair.
Torsello GF; Beropoulis E; Munaò R; Trimarchi S; Torsello GB; Austermann M
J Vasc Surg; 2020 Sep; 72(3):859-865. PubMed ID: 31964573
[TBL] [Abstract][Full Text] [Related]
5. Outcomes of Advanta V12 Covered Stents After Fenestrated Endovascular Aneurysm Repair.
van der Riet C; Schuurmann RCL; Verhoeven ELG; Zeebregts CJ; Tielliu IFJ; Bokkers RPH; Katsargyris A; de Vries JPM
J Endovasc Ther; 2021 Oct; 28(5):700-706. PubMed ID: 34008441
[TBL] [Abstract][Full Text] [Related]
6. In Vitro Evaluation of Balloon-Expandable Chimney Grafts in the Renal Arteries Combined With the Endurant Endograft.
Taneva GT; Donas KP; Torsello GB; Seifarth H; de Azevedo FM; Austermann M; Torsello GF
J Endovasc Ther; 2019 Dec; 26(6):865-870. PubMed ID: 31455137
[No Abstract] [Full Text] [Related]
7. Performance of Viabahn balloon-expandable stent compared with self-expandable covered stents for branched endovascular aortic repair.
Motta F; Parodi FE; Knowles M; Crowner JR; Pascarella L; McGinigle KL; Marston WA; Kibbe MR; Ohana E; Farber MA
J Vasc Surg; 2021 Feb; 73(2):410-416.e2. PubMed ID: 32473341
[TBL] [Abstract][Full Text] [Related]
8. First/Preliminary Experience of Gore Viabahn Balloon-Expandable Endoprosthesis as Bridging Stent in Fenestrated and Branched Endovascular Aortic Repair.
Gallitto E; Faggioli G; Pini R; Mascoli C; Sonetto A; Abualhin M; Logiacco A; Ricco JB; Gargiulo M
Ann Vasc Surg; 2019 Nov; 61():299-309. PubMed ID: 31376538
[TBL] [Abstract][Full Text] [Related]
9. Initial Experience With Viabahn VBX as the Bridging Stent Graft for Branched and Fenestrated Endovascular Aneurysm Repair.
Mafeld S; Annamalai G; Lindsay TF; Zhong I; Tarulli E; Mironov O; Tan KT
Vasc Endovascular Surg; 2019 Jul; 53(5):395-400. PubMed ID: 31018828
[TBL] [Abstract][Full Text] [Related]
10. Outcomes of chimney and fenestrated endografting using Viabahn VBX and atrium iCAST stents.
Clark EC; Babrowski TA; Milner R
J Cardiovasc Surg (Torino); 2021 Apr; 62(2):136-145. PubMed ID: 33302612
[TBL] [Abstract][Full Text] [Related]
11. Gutter Characteristics and Stent Compression of Self-Expanding vs Balloon-Expandable Chimney Grafts in Juxtarenal Aneurysm Models.
Meekel JP; van Schaik TG; Lely RJ; Groot G; van der Meijs BB; Wisselink W; Blankensteijn JD; Yeung KK
J Endovasc Ther; 2020 Jun; 27(3):452-461. PubMed ID: 32314658
[No Abstract] [Full Text] [Related]
12. Outcomes of directional branches using self-expandable or balloon-expandable stent grafts during endovascular repair of thoracoabdominal aortic aneurysms.
Tenorio ER; Kärkkäinen JM; Mendes BC; DeMartino RR; Macedo TA; Diderrich A; Hofer J; Oderich GS
J Vasc Surg; 2020 May; 71(5):1489-1502.e6. PubMed ID: 31611106
[TBL] [Abstract][Full Text] [Related]
13. Performance of the Gore VBX Balloon Expandable Endoprosthesis as Bridging Stent-Graft in Branched Endovascular Aortic Repair for Thoracoabdominal Aneurysms.
Torsello GB; Pitoulias A; Litterscheid S; Berekoven B; Torsello GF; Austermann M; Bosiers MJ
J Endovasc Ther; 2021 Aug; 28(4):549-554. PubMed ID: 33908821
[TBL] [Abstract][Full Text] [Related]
14. In Situ Laser Fenestration Technique: Bench-Testing of Aortic Endograft to Guide Clinical Practice.
Grima MJ; Wanhainen A; Lindström D
J Endovasc Ther; 2024 Feb; 31(1):126-131. PubMed ID: 36000361
[TBL] [Abstract][Full Text] [Related]
15. Preliminary Outcomes of Viabahn Balloon-Expandable Endoprosthesis as Bridging Stent in Renal Arteries During Fenestrated Endovascular Aortic Repair.
Mezzetto L; Mastrorilli D; Leone N; Gennai S; Silingardi R; Veraldi GF; Piazza M; Squizzato F; Antonello M
J Endovasc Ther; 2021 Aug; 28(4):575-584. PubMed ID: 33973493
[TBL] [Abstract][Full Text] [Related]
16. Changes in Target Vessel Anatomy Following Fenestrated Endovascular Aneurysm Repair: Midterm Results.
Keschenau PR; Sattler C; Berger T; Kotelis D; Jacobs MJ; Kalder J
J Endovasc Ther; 2020 Jun; 27(3):445-451. PubMed ID: 32316825
[No Abstract] [Full Text] [Related]
17. Performance of BeGraft and BeGraft+ Stent-Grafts as Bridging Devices for Fenestrated Endovascular Aneurysm Repair: An In Vitro Study.
Torsello GF; Herten M; Frank A; Müller M; Jung S; Torsello GB; Austermann M
J Endovasc Ther; 2019 Dec; 26(6):787-794. PubMed ID: 31379276
[No Abstract] [Full Text] [Related]
18. In Vitro Radiological Evaluation of Different Types of Chimney Stents Using a Silicon Flow Model with Adjustable Physiological Simulating Conditions.
Taneva GT; Usai MV; Pitoulias GA; Donas KP
Eur J Vasc Endovasc Surg; 2023 Aug; 66(2):270-277. PubMed ID: 37172689
[TBL] [Abstract][Full Text] [Related]
19. Use of Stainless-Steel, Balloon-Expandable Chimney Grafts Is Durable Though Caution Is Required When Lining Angulated Renal Arteries.
Taneva GT; Fazzini S; Pipitone MD; Karaolanis G; Torsello G; Bremer C; Austermann M; Donas KP
J Endovasc Ther; 2020 Dec; 27(6):902-909. PubMed ID: 32813593
[TBL] [Abstract][Full Text] [Related]
20. Atrium Advanta V12 Large Diameter Stent-Graft Applications for Infrarenal Abdominal Aortic Pseudoaneurysms (due to Behcet Disease): Safety and Efficacy.
Altay ÇM; Alpar A; Topcuoglu OM; Kucukay MB; Cansu DU; Temel T; Ozbulbul NI; Kucukay F
Ann Vasc Surg; 2017 Oct; 44():197-202. PubMed ID: 28479445
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]