These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

253 related articles for article (PubMed ID: 3362988)

  • 21. New four-stitch sleeve anastomosis: an experimental study in rats with reports of clinical use.
    Zhang L; Moskowitz M; Ostad D; Kessler K; Siebert JW
    Microsurgery; 1996; 17(6):291-4. PubMed ID: 9308711
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [Experimental study of the reliability of end to end arterial microanastomosis].
    Cariou JL; Vergote T; Arrouvel C; Banzet P
    Ann Chir Plast Esthet; 1993 Oct; 38(5):599-611. PubMed ID: 7944236
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Use of longitudinal invaginating matrix sutures in microarterial sleeve anastomoses.
    Güneren E; Odaci E; Yildiz L; Akbaş H; Eroğlu L; Kaplan S
    Scand J Plast Reconstr Surg Hand Surg; 2004; 38(1):1-4. PubMed ID: 15074715
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Microvascular anastomosis using 2-octyl cyanoacrylate in the rat femoral artery.
    Hall WW; Wrye SW; Banducci DR; Ehrlich P
    Ann Plast Surg; 2000 May; 44(5):508-11. PubMed ID: 10805301
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Experimental study on healing processes after microvascular anastomoses of normal rat femoral arteries and veins--light and scanning electron microscopy studies].
    Adachi F
    Shikwa Gakuho; 1986 Jun; 86(6):987-1019. PubMed ID: 3466353
    [No Abstract]   [Full Text] [Related]  

  • 26. In search of the "perfect" anastomosis.
    Guity A; Young PH; Fischer VW
    Microsurgery; 1990; 11(1):5-11. PubMed ID: 2182965
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Introduction of loop sutures in microsurgical telescoping anastomosis.
    Saitoh S; Nakatsuchi Y
    Br J Plast Surg; 1993 Mar; 46(2):105-9. PubMed ID: 8461897
    [TBL] [Abstract][Full Text] [Related]  

  • 28. The thermic vascular anastomosis (TVA). IV. Analysis by scanning electron microscopy.
    Wintermantel E
    Acta Neurochir (Wien); 1983; 67(1-2):139-53. PubMed ID: 6837344
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Venous microanastomosis with the Unilink system, sleeve, and suture techniques: a comparative study in the rat.
    Zhang L; Kolker AR; Choe EI; Bakshandeh N; Josephson G; Wu FC; Siebert JW; Kasabian AK
    J Reconstr Microsurg; 1997 May; 13(4):257-61; discussion 261-2. PubMed ID: 9144138
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Experimental microvenous reconstructions with Gore-Tex polytetrafluoroethylene prosthesis implanted by means of the sleeve anastomotic technique.
    van der Lei B; Bartels HL; Dijk F; Schakenraad JM; Nieuwenhuis P; Robinson PH
    Microsurgery; 1991; 12(1):23-9. PubMed ID: 1990245
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Scanning electron microscopic analysis of the stapled microvascular anastomosis in the rabbit.
    Boeckx WD; Darius O; van den hof B; van Holder C
    Ann Thorac Surg; 1997 Jun; 63(6 Suppl):S128-34. PubMed ID: 9203617
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Microvascular anastomoses using an Nd-YAG laser.
    Nakamura T; Fukui A; Maeda M; Kugai M; Inada Y; Teramoto N; Ishida A; Tamai S
    J Reconstr Microsurg; 2000 Oct; 16(7):577-84. PubMed ID: 11083400
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Favorable scanning electron microscopic findings of stapled saphenous vein-carotid artery anastomoses.
    Izzat MB; Yim AP; Ho KC; Chan CS; Yew D; Chow LT
    Ann Thorac Surg; 1999 Jan; 67(1):85-8. PubMed ID: 10086529
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Sutureless laser-welded anastomosis of the femoral artery and vein in rats using CO2 and Nd:YAG lasers.
    Bürger RA; Gerharz CD; Draws J; Engelmann UH; Hohenfellner R
    J Reconstr Microsurg; 1993 May; 9(3):213-8. PubMed ID: 8515400
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Comparison of tensile strength and thrombus formation between mechanical microvascular anastomoses using a biodegradable ring device and sutured anastomoses.
    Ichikawa M; Muneshige H; Ikuta Y
    J Reconstr Microsurg; 2002 Feb; 18(2):131-6; discussion 137-9. PubMed ID: 11823945
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Experimental diode laser-assisted microvascular anastomosis.
    Reali UM; Gelli R; Giannotti V; Gori F; Pratesi R; Pini R
    J Reconstr Microsurg; 1993 May; 9(3):203-10; discussion 210-1. PubMed ID: 8515399
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Use of a continuous suture for back wall repair of end-to-end or end-to-side anastomoses.
    Harashina T
    Plast Reconstr Surg; 1982 Jan; 69(1):139-44. PubMed ID: 7031718
    [No Abstract]   [Full Text] [Related]  

  • 38. Who needs extra time? Amniotic membrane wrapped pauci-suture model for rapid anastomoses
    Ercin BS; Bicer A; Yigitturk G; Cinar C; Cavusoglu T; Uyanikgil Y; Gurler T
    J Plast Surg Hand Surg; 2019 Apr; 53(2):89-96. PubMed ID: 30654665
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Effect of heparinized irrigating solutions on patency of experimental microvascular anastomoses.
    Zinberg EM; Choo DI; Zotter LA
    Microsurgery; 1989; 10(2):103-7; discussion 108-9. PubMed ID: 2528050
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Experimental laser-assisted end-to-side microvascular anastomosis.
    Sartorius CJ; Shapiro SA; Campbell RL; Klatte EC; Clark SA
    Microsurgery; 1986; 7(2):79-83. PubMed ID: 3724430
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 13.