These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

246 related articles for article (PubMed ID: 3362988)

  • 41. Resin corrosion cast in experimental evaluation of femoral microanastomosis.
    Travers V; Kanaujia RR; Ikuta Y
    Ann Chir Main; 1987; 6(4):324-7. PubMed ID: 3329491
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Are mechanical microvascular anastomoses easier to learn than suture anastomoses?
    Zdolsek J; Ledin H; Lidman D
    Microsurgery; 2005; 25(8):596-8. PubMed ID: 16284953
    [TBL] [Abstract][Full Text] [Related]  

  • 43. A comparison by burst testing of three types of vascular anastomosis.
    Klein SL; Chen H; Israel-Graff J
    Microsurgery; 1998; 18(1):29-32. PubMed ID: 9635791
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Long term evaluation of the unilink anastomotic system. A study with light and scanning electron microscopy.
    Ragnarsson R; Berggren A; Ostrup LT
    Scand J Plast Reconstr Surg Hand Surg; 1992; 26(2):167-71. PubMed ID: 1411344
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Argon laser-assisted anastomoses in medium-size vessels: one-year follow-up.
    Kuroyanagi Y; Taguchi M; Yano T; Jones DN; Shionoya S
    Lasers Surg Med; 1991; 11(3):223-31. PubMed ID: 1861561
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Effect of torsion on microarterial anastomosis patency.
    Topalan M; Bilgin SS; Ip WY; Chow SP
    Microsurgery; 2003; 23(1):56-9. PubMed ID: 12616520
    [TBL] [Abstract][Full Text] [Related]  

  • 47. [VCS microclip anastomosis on blood vessels of less than 2 millimeters in diameter. Preliminary experimental study in the rat].
    Gerbault O; Arrouvel C; Servant JM; Revol M; Banzet P
    Ann Chir Plast Esthet; 1998 Feb; 43(1):27-39. PubMed ID: 9768090
    [TBL] [Abstract][Full Text] [Related]  

  • 48. The effect of twisting on microanastomotic patency of arteries and veins in a rat model.
    Salgarello M; Lahoud P; Selvaggi G; Gentileschi S; Sturla M; Farallo E
    Ann Plast Surg; 2001 Dec; 47(6):643-6. PubMed ID: 11756835
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Microvascular vein-graft patency in the rat model.
    Zhang F; Oliva A; Kao SD; Newlin L; Buncke HJ
    J Reconstr Microsurg; 1994 Jul; 10(4):223-7. PubMed ID: 7965995
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Patency of laser-assisted anastomoses in small vessels: one-year follow-up.
    McCarthy WJ; LoCicero J; Hartz RS; Yao JS
    Surgery; 1987 Aug; 102(2):319-26. PubMed ID: 3112983
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Application of fibrin glue in microvascular anastomoses: comparative analysis with the conventional suture technique using a free flap model.
    Cho AB; Júnior RM
    Microsurgery; 2008; 28(5):367-74. PubMed ID: 18561266
    [TBL] [Abstract][Full Text] [Related]  

  • 52. An alternative technique of microvascular anastomosis.
    Hou SM; Seaber AV; Urbaniak JR
    Microsurgery; 1987; 8(1):22-4. PubMed ID: 3295464
    [TBL] [Abstract][Full Text] [Related]  

  • 53. An experimental study of the sleeve technique in microarterial anastomoses.
    Sully L; Nightingale MG; O'Brien BM; Hurley JV
    Plast Reconstr Surg; 1982 Aug; 70(2):186-92. PubMed ID: 7048368
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Experimental microvascular sleeve anastomosis in size discrepancy vessels.
    de la Peña-Salcedo JA; Cuesy C; López-Monjardin H
    Microsurgery; 2000; 20(4):173-5. PubMed ID: 10980516
    [TBL] [Abstract][Full Text] [Related]  

  • 55. A simple method for evaluating the quality of microvascular anastomoses performed in vitro.
    Menovsky T; Van Loock K; Wang WT; Ferraz-Leite H; De Ridder D
    World Neurosurg; 2012 Feb; 77(2):388-90. PubMed ID: 22120392
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Scanning electron microscopy studies of needle and suture damage in rat carotid and femoral arteries.
    Longa EZ; Weinstein PR; Chater G
    Microsurgery; 1984; 5(4):169-74. PubMed ID: 6392817
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Analysis of suturing techniques in the microvascular anastomosis of vessels of unequal diameter.
    Ahn CY; Borud LJ; Shaw WW
    Ann Plast Surg; 1994 May; 32(5):469-73. PubMed ID: 8060069
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Use of continuous horizontal mattress suture techniques in microsurgery: an experimental study in rats.
    Tetik C; Unal MB; Kocaoglu B; Erol B
    J Hand Surg Am; 2005 May; 30(3):587-95. PubMed ID: 15925172
    [TBL] [Abstract][Full Text] [Related]  

  • 59. The effects of artificial postoperative hematoma on patency of microvascular anastomoses in rat femoral blood vessels.
    Sadove R; Cline C; Buncke HJ
    J Microsurg; 1979; 1(1):50-5. PubMed ID: 16317928
    [TBL] [Abstract][Full Text] [Related]  

  • 60. [End-to-side anastomosis of the carotid artery of the rat with a modified suture technique. Scanning electron microscopy study].
    Schön R
    Zentralbl Neurochir; 1990; 51(2):112-5. PubMed ID: 2087886
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 13.