These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

110 related articles for article (PubMed ID: 33629926)

  • 21. Reduction of superficial radiation dose with bolus in passive scattering proton beam therapy.
    Kim YJ; Kim C; Lee SB; Kim JS
    J Appl Clin Med Phys; 2021 Feb; 22(2):69-76. PubMed ID: 33433064
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [3. Application of monte carlo simulations to radiology].
    Sutherland KL
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2014 Aug; 70(8):827-38. PubMed ID: 25142395
    [No Abstract]   [Full Text] [Related]  

  • 23. A standardized commissioning framework of Monte Carlo dose calculation algorithms for proton pencil beam scanning treatment planning systems.
    Chang CW; Huang S; Harms J; Zhou J; Zhang R; Dhabaan A; Slopsema R; Kang M; Liu T; McDonald M; Langen K; Lin L
    Med Phys; 2020 Apr; 47(4):1545-1557. PubMed ID: 31945191
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Accurate Monte Carlo simulations for nozzle design, commissioning and quality assurance for a proton radiation therapy facility.
    Paganetti H; Jiang H; Lee SY; Kooy HM
    Med Phys; 2004 Jul; 31(7):2107-18. PubMed ID: 15305464
    [TBL] [Abstract][Full Text] [Related]  

  • 25. GATE MODELING OF LATERAL SCATTERING OF PROTON PENCIL BEAMS.
    Zarifi S; Ahangari HT; Jia SB; Tajik-Mansoury MA; Najafzadeh M
    Radiat Prot Dosimetry; 2020 Jul; 189(1):76-88. PubMed ID: 32112096
    [TBL] [Abstract][Full Text] [Related]  

  • 26. 4D Monte Carlo simulation of proton beam scanning: modelling of variations in time and space to study the interplay between scanning pattern and time-dependent patient geometry.
    Paganetti H; Jiang H; Trofimov A
    Phys Med Biol; 2005 Mar; 50(5):983-90. PubMed ID: 15798270
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Monte Carlo and analytical calculation of proton pencil beams for computerized treatment plan optimization.
    Carlsson AK; Andreo P; Brahme A
    Phys Med Biol; 1997 Jun; 42(6):1033-53. PubMed ID: 9194127
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Four-dimensional Monte Carlo simulation of time-dependent geometries.
    Paganetti H
    Phys Med Biol; 2004 Mar; 49(6):N75-81. PubMed ID: 15104330
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Monte Carlo simulations of a nozzle for the treatment of ocular tumours with high-energy proton beams.
    Newhauser W; Koch N; Hummel S; Ziegler M; Titt U
    Phys Med Biol; 2005 Nov; 50(22):5229-49. PubMed ID: 16264250
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A pencil beam algorithm for intensity modulated proton therapy derived from Monte Carlo simulations.
    Soukup M; Fippel M; Alber M
    Phys Med Biol; 2005 Nov; 50(21):5089-104. PubMed ID: 16237243
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Validation and clinical implementation of an accurate Monte Carlo code for pencil beam scanning proton therapy.
    Huang S; Kang M; Souris K; Ainsley C; Solberg TD; McDonough JE; Simone CB; Lin L
    J Appl Clin Med Phys; 2018 Sep; 19(5):558-572. PubMed ID: 30058170
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Validation of nuclear models in Geant4 using the dose distribution of a 177 MeV proton pencil beam.
    Hall DC; Makarova A; Paganetti H; Gottschalk B
    Phys Med Biol; 2016 Jan; 61(1):N1-N10. PubMed ID: 26611861
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Validation of linear energy transfer computed in a Monte Carlo dose engine of a commercial treatment planning system.
    Wagenaar D; Tran LT; Meijers A; Marmitt GG; Souris K; Bolst D; James B; Biasi G; Povoli M; Kok A; Traneus E; van Goethem MJ; Langendijk JA; Rosenfeld AB; Both S
    Phys Med Biol; 2020 Jan; 65(2):025006. PubMed ID: 31801119
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Experimental benchmarking of RayStation proton dose calculation algorithms inside and outside the target region in heterogeneous phantom geometries.
    Ruangchan S; Knäusl B; Fuchs H; Georg D; Clausen M
    Phys Med; 2020 Aug; 76():182-193. PubMed ID: 32693355
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A dose calculation algorithm with correction for proton-nucleus interactions in non-water materials for proton radiotherapy treatment planning.
    Inaniwa T; Kanematsu N; Sato S; Kohno R
    Phys Med Biol; 2016 Jan; 61(1):67-89. PubMed ID: 26611641
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Validation of the RayStation Monte Carlo dose calculation algorithm using a realistic lung phantom.
    Schreuder AN; Bridges DS; Rigsby L; Blakey M; Janson M; Hedrick SG; Wilkinson JB
    J Appl Clin Med Phys; 2019 Dec; 20(12):127-137. PubMed ID: 31763759
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Radiobiological and dosimetric impact of RayStation pencil beam and Monte Carlo algorithms on intensity-modulated proton therapy breast cancer plans.
    Rana S; Greco K; Samuel EJJ; Bennouna J
    J Appl Clin Med Phys; 2019 Aug; 20(8):36-46. PubMed ID: 31343826
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Computer-assisted beam modeling for particle therapy.
    Fuchs H; Elia A; Resch AF; Kuess P; Lühr A; Vidal M; Grevillot L; Georg D
    Med Phys; 2021 Feb; 48(2):841-851. PubMed ID: 33283910
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A model for the accurate computation of the lateral scattering of protons in water.
    Bellinzona EV; Ciocca M; Embriaco A; Ferrari A; Fontana A; Mairani A; Parodi K; Rotondi A; Sala P; Tessonnier T
    Phys Med Biol; 2016 Feb; 61(4):N102-17. PubMed ID: 26808380
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Improvements in pencil beam scanning proton therapy dose calculation accuracy in brain tumor cases with a commercial Monte Carlo algorithm.
    Widesott L; Lorentini S; Fracchiolla F; Farace P; Schwarz M
    Phys Med Biol; 2018 Jul; 63(14):145016. PubMed ID: 29726402
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.