These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
4. First-Pass Effect in M1-Occlusion Stroke Patients Treated with Combined Stent-Retriever/Large-Bore Distal Aspiration Catheter Thrombectomy. Remollo S; Werner M; Blasco J; López-Rueda A; San Roman L; Jimenez-Gomez E; Bravo Rey I; Vega P; Murias E; Rosati S; Pérez-García C; González E; Manso X; Aixut S; Chirife Chaparro O; Terceño M; Bashir S; Pumar JM; Ruiz-González E; Méndez JC; Aguilar Tejedor Y; Zamarro J; Castaño M; Daunis-I-Estadella P; Puig J; Clin Neuroradiol; 2023 Sep; 33(3):701-708. PubMed ID: 36856786 [TBL] [Abstract][Full Text] [Related]
5. Walrus large bore guide catheter impact on recanalization first pass effect and outcomes: the WICkED study. Cortez GM; Turner RD; Monteiro A; Puri AS; Siddiqui AH; Mocco J; Vargas J; Kuhn AL; Majidi S; Chaudry MI; Aghaebrahim A; Turk AS; Sauvageau E; Hanel RA J Neurointerv Surg; 2022 Mar; 14(3):280-285. PubMed ID: 33858971 [TBL] [Abstract][Full Text] [Related]
6. BOBBY balloon guide catheter thrombectomy in large-vessel occlusion stroke: Initial experience. Topiwala K; Quinn C; Mehta T; Masood K; Grande A; Tummala R; Jagadeesan B Interv Neuroradiol; 2024 Feb; 30(1):80-85. PubMed ID: 35645160 [TBL] [Abstract][Full Text] [Related]
7. Impact of balloon guide catheter on technical and clinical outcomes: a systematic review and meta-analysis. Brinjikji W; Starke RM; Murad MH; Fiorella D; Pereira VM; Goyal M; Kallmes DF J Neurointerv Surg; 2018 Apr; 10(4):335-339. PubMed ID: 28754806 [TBL] [Abstract][Full Text] [Related]
8. Comparison of balloon guide catheter versus non-balloon guide catheter for mechanical thrombectomy in patients with distal medium vessel occlusion. Orscelik A; Kallmes DF; Bilgin C; Musmar B; Senol YC; Kobeissi H; Elawady SS; Cunningham C; Matsukawa H; Zandpazandi S; Sowlat MM; Maier I; Al Kasab S; Jabbour P; Kim JT; Wolfe SQ; Rai A; Starke RM; Psychogios MN; Samaniego EA; Arthur AS; Yoshimura S; Cuellar H; Howard BM; Alawieh A; Romano DG; Tanweer O; Mascitelli J; Fragata I; Polifka AJ; Osbun JW; Crosa RJ; Matouk C; Park MS; Levitt MR; Moss M; Dumont TM; Williamson R; Navia P; Kan P; De Leacy R; Chowdhry SA; Ezzeldin M; Spiotta AM; Brinjikji W; J Neurointerv Surg; 2024 May; 16(6):587-594. PubMed ID: 37918906 [TBL] [Abstract][Full Text] [Related]
9. Effect of balloon guide catheter on clinical outcomes and reperfusion in Trevo thrombectomy. Nguyen TN; Castonguay AC; Nogueira RG; Haussen DC; English JD; Satti SR; Chen J; Farid H; Borders C; Veznedaroglu E; Binning MJ; Puri AS; Vora NA; Budzik RF; Dabus G; Linfante I; Janardhan V; Alshekhlee A; Abraham MG; Edgell RC; Taqi MA; El Khoury R; Mokin M; Majjhoo AQ; Kabbani MR; Froehler MT; Finch I; Ansari SA; Novakovic R; Abdalkader M; Zaidat OO J Neurointerv Surg; 2019 Sep; 11(9):861-865. PubMed ID: 30712011 [TBL] [Abstract][Full Text] [Related]
10. Endovascular stroke treatment using balloon guide catheters may reduce penumbral tissue damage and improve long-term outcome. Berndt MT; Goyal M; Psychogios M; Kaesmacher J; Boeckh-Behrens T; Wunderlich S; Zimmer C; Friedrich B; Maegerlein C Eur Radiol; 2021 Apr; 31(4):2191-2198. PubMed ID: 33037911 [TBL] [Abstract][Full Text] [Related]
11. Procedural approaches and angiographic signs predicting first-pass recanalization in patients treated with mechanical thrombectomy for acute ischaemic stroke. Tomasello A; Ribò M; Gramegna LL; Melendez F; Rosati S; Moreu M; Aixut S; Lüttich A; Werner M; Remollo S; Quintana M; Coscojuela P; Hernandez D; Dinia L; Lopez-Rueda A; Rubiera M; Rovira À Interv Neuroradiol; 2019 Oct; 25(5):491-496. PubMed ID: 31072248 [TBL] [Abstract][Full Text] [Related]
12. Cyclical aspiration using a novel mechanical thrombectomy device is associated with a high TICI 3 first pass effect in large-vessel strokes. Kalousek V; Yoo AJ; Sheth SA; Janardhan V; Mamic J; Janardhan V J Neuroimaging; 2021 Sep; 31(5):912-924. PubMed ID: 34101284 [TBL] [Abstract][Full Text] [Related]
13. A propensity score-matched comparative study of balloon guide catheters versus conventional guide catheters for concurrent mechanical thrombectomy with carotid stenting in tandem strokes: comparison of first pass effect, symptomatic intracranial hemorrhage, and 90-day functional outcomes. Baig AA; Waqas M; Turner RC; Kuo CC; Donnelly BM; Lai PMR; Raygor KP; Bouslama M; Lim J; Neumaier Bs J; Cappuzzo JM; Davies JM; Snyder KV; Siddiqui AH; Levy EI J Neurointerv Surg; 2024 Jan; 16(2):124-130. PubMed ID: 37076277 [TBL] [Abstract][Full Text] [Related]
14. First Pass Effect: A New Measure for Stroke Thrombectomy Devices. Zaidat OO; Castonguay AC; Linfante I; Gupta R; Martin CO; Holloway WE; Mueller-Kronast N; English JD; Dabus G; Malisch TW; Marden FA; Bozorgchami H; Xavier A; Rai AT; Froehler MT; Badruddin A; Nguyen TN; Taqi MA; Abraham MG; Yoo AJ; Janardhan V; Shaltoni H; Novakovic R; Abou-Chebl A; Chen PR; Britz GW; Sun CJ; Bansal V; Kaushal R; Nanda A; Nogueira RG Stroke; 2018 Mar; 49(3):660-666. PubMed ID: 29459390 [TBL] [Abstract][Full Text] [Related]
15. First pass effect in patients with large vessel occlusion strokes undergoing neurothrombectomy: insights from the Trevo Retriever Registry. Jadhav AP; Desai SM; Budzik RF; Gupta R; Baxter B; English JD; Bartolini BM; Krajina A; Haussen DC; Nogueira RG; Liebeskind D; Veznedaroglu E J Neurointerv Surg; 2021 Jul; 13(7):619-622. PubMed ID: 33479032 [TBL] [Abstract][Full Text] [Related]
16. Mechanical thrombectomy with a balloon-guide catheter: sheathless transradial versus transfemoral approach. Waqas M; Monteiro A; Cappuzzo JM; Kruk MD; Almayman F; Housley SB; Lim J; Dossani RH; Snyder KV; Siddiqui AH; Davies JM; Levy EI J Neurointerv Surg; 2024 Jan; 16(2):187-191. PubMed ID: 36581453 [TBL] [Abstract][Full Text] [Related]
17. Matched-pair analysis of patients with ischemic stroke undergoing thrombectomy using next-generation balloon guide catheters. Kim LH; Choi J; Zhou J; Wolman D; Pendharkar AV; Lansberg MG; Albers GW; Dodd R; Do HM; Pulli B; Heit JJ; Telischak NA J Neurointerv Surg; 2024 May; 16(6):595-598. PubMed ID: 37793796 [TBL] [Abstract][Full Text] [Related]
18. Comparing the Conventional and Balloon-Guided Catheter-Assisted SWIM Technology for the Treatment of Acute Ischemic Stroke. Chen Z; Liu Y; Li B; Yuan C; Hou K; Chen L; Li P Front Neurol; 2022; 13():866673. PubMed ID: 35911914 [TBL] [Abstract][Full Text] [Related]
19. Usefulness of combination usage of balloon guide catheter with contact aspiration thrombectomy. Kim YW; Kang DH; Son W; Hwang YH; Kim YS; Shin JW; Lim JW; Koh HS; Kwon HJ Acta Neurochir (Wien); 2021 Jun; 163(6):1787-1797. PubMed ID: 33723972 [TBL] [Abstract][Full Text] [Related]
20. Distal placement of balloon guide catheter facilitates stent-retriever mechanical thrombectomy for acute ischemic stroke in the anterior circulation. Lee IH; Ha SK; Lim DJ; Choi JI Acta Neurochir (Wien); 2023 Dec; 165(12):3759-3768. PubMed ID: 37816916 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]