These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

169 related articles for article (PubMed ID: 33634549)

  • 1. Ablation Index-guided high-power (50 W) short-duration for left atrial anterior and roofline ablation: Feasibility, procedural data, and lesion analysis (AI High-Power Linear Ablation).
    Zanchi S; Chen S; Bordignon S; Bianchini L; Tohoku S; Bologna F; Tondo C; Chun KRJ; Schmidt B
    J Cardiovasc Electrophysiol; 2021 Apr; 32(4):984-993. PubMed ID: 33634549
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Ablation index-guided 50 W ablation for pulmonary vein isolation in patients with atrial fibrillation: Procedural data, lesion analysis, and initial results from the FAFA AI High Power Study.
    Chen S; Schmidt B; Bordignon S; Urbanek L; Tohoku S; Bologna F; Angelkov L; Garvanski I; Tsianakas N; Konstantinou A; Trolese L; Weise F; Perrotta L; Chun KRJ
    J Cardiovasc Electrophysiol; 2019 Dec; 30(12):2724-2731. PubMed ID: 31588620
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Catheter ablation of atrial fibrillation using ablation index-guided high-power technique: Frankfurt AI high-power 15-month follow-up.
    Chen S; Schmidt B; Bordignon S; Tohoku S; Urban VC; Schulte-Hahn B; Chun KRJ
    J Cardiovasc Electrophysiol; 2021 Mar; 32(3):616-624. PubMed ID: 33484215
    [TBL] [Abstract][Full Text] [Related]  

  • 4. High-Power Short-Duration Lesion Index-Guided Posterior Wall Isolation beyond Pulmonary Vein Isolation for Persistent Atrial Fibrillation.
    Conti S; Sabatino F; Fortunato F; Ferrara G; Cascino A; Sgarito G
    J Clin Med; 2023 Aug; 12(16):. PubMed ID: 37629269
    [No Abstract]   [Full Text] [Related]  

  • 5. Catheter ablation of atrial fibrillation using ablation index-guided high power (50 W) for pulmonary vein isolation with or without esophageal temperature probe (the AI-HP ESO II).
    Chen S; Schmidt B; Seeger A; Bordignon S; Tohoku S; Willems F; Urbanek L; Throm C; Konstantinou A; Plank K; Hilbert M; Zanchi S; Bianchini L; Bologna F; Tsianakas N; Kreuzer C; Chun KRJ
    Heart Rhythm; 2020 Nov; 17(11):1833-1840. PubMed ID: 32470628
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Left atrial anterior line ablation using ablation index and inter-lesion distance measurement.
    Santoro F; Metzner A; Brunetti ND; Heeger CH; Mathew S; Reissmann B; Lemeš C; Maurer T; Fink T; Rottner L; Inaba O; Kuck KH; Ouyang F; Rillig A
    Clin Res Cardiol; 2019 Sep; 108(9):1009-1016. PubMed ID: 30712147
    [TBL] [Abstract][Full Text] [Related]  

  • 7. High-power application is associated with shorter procedure time and higher rate of first-pass pulmonary vein isolation in ablation index-guided atrial fibrillation ablation.
    Okamatsu H; Koyama J; Sakai Y; Negishi K; Hayashi K; Tsurugi T; Tanaka Y; Nakao K; Sakamoto T; Okumura K
    J Cardiovasc Electrophysiol; 2019 Dec; 30(12):2751-2758. PubMed ID: 31600006
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Direct comparison of two 50 W high power short duration approaches-Temperature- versus ablation index-guided radiofrequency ablation for atrial fibrillation.
    Guckel D; Bergau L; Braun M; El Hamriti M; Mörsdorf M; Fink T; Sciacca V; Khalaph M; Imnadze G; Sommer P; Sohns C
    J Cardiovasc Electrophysiol; 2022 Dec; 33(12):2517-2527. PubMed ID: 36104929
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Personalized pulmonary vein isolation with very high-power short-duration lesions guided by left atrial wall thickness: the QDOT-by-LAWT randomized trial.
    Falasconi G; Penela D; Soto-Iglesias D; Francia P; Saglietto A; Turturiello D; Viveros D; Bellido A; Alderete J; Zaraket F; Franco-Ocaña P; Huguet M; Cámara Ó; Vătășescu R; Ortiz-Pérez JT; Martí-Almor J; Berruezo A
    Europace; 2024 Mar; 26(4):. PubMed ID: 38652090
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Procedural efficacy and safety of standardized, ablation index guided fixed 50 W high-power short-duration pulmonary vein isolation and substrate modification using the CLOSE protocol.
    Francke A; Taha NS; Scharfe F; Schoen S; Wunderlich C; Christoph M
    J Cardiovasc Electrophysiol; 2021 Sep; 32(9):2408-2417. PubMed ID: 34252990
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Important factors in left atrial posterior wall isolation using 28-mm cryoballoon ablation for persistent atrial fibrillation-Block line or isolation area?
    Nanbu T; Yotsukura A; Suzuki G; Ishidoya Y; Sano F; Yoshida I; Sakurai M
    J Cardiovasc Electrophysiol; 2020 Jan; 31(1):119-127. PubMed ID: 31746038
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Prospective use of Ablation Index targets improves clinical outcomes following ablation for atrial fibrillation.
    Hussein A; Das M; Chaturvedi V; Asfour IK; Daryanani N; Morgan M; Ronayne C; Shaw M; Snowdon R; Gupta D
    J Cardiovasc Electrophysiol; 2017 Sep; 28(9):1037-1047. PubMed ID: 28639728
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Atrial fibrillation ablation workflow optimization facilitated by high-power short-duration ablation and high-resolution mapping.
    Fink T; Sciacca V; Nischik F; Bergau L; Guckel D; El Hamriti M; Khalaph M; Braun M; Winnik S; Didenko M; Imnadze G; Sommer P; Sohns C
    Europace; 2024 Mar; 26(3):. PubMed ID: 38516791
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Pulmonary vein isolation guided by moderate ablation index targets combined with strict procedural endpoints for patients with paroxysmal atrial fibrillation.
    Wang YJ; Tian Y; Shi L; Zeng LJ; Xie BQ; Li XX; Yang XC; Liu XP
    J Cardiovasc Electrophysiol; 2021 Jul; 32(7):1842-1848. PubMed ID: 34028119
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Reconnection patterns after CLOSE-guided 50 W high-power-short-duration circumferential pulmonary vein isolation and substrate modification-PV reconnection might no longer be an issue.
    Francke A; Scharfe F; Schoen S; Wunderlich C; Christoph M
    J Cardiovasc Electrophysiol; 2022 Jun; 33(6):1136-1145. PubMed ID: 35118734
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Ablation Index Guided Left Atrial Posterior Wall Isolation.
    Makihara Y; Miyazaki S; Harama T; Obunai K; Watanabe H; Tada H
    Int Heart J; 2022; 63(4):708-715. PubMed ID: 35908854
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Posterior wall substrate modification using optimized and contiguous lesions in patients with atrial fibrillation.
    Sohns C; Bergau L; El Hamriti M; Fox H; Molatta S; Braun M; Khalaph M; Imnadze G; Sommer P
    Cardiol J; 2022; 29(6):917-926. PubMed ID: 33346368
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Techniques, evaluation, and consequences of linear block at the left atrial roof in paroxysmal atrial fibrillation: a prospective randomized study.
    Hocini M; Jaïs P; Sanders P; Takahashi Y; Rotter M; Rostock T; Hsu LF; Sacher F; Reuter S; Clémenty J; Haïssaguerre M
    Circulation; 2005 Dec; 112(24):3688-96. PubMed ID: 16344401
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Safety and outcome of very high-power short-duration ablation using 70 W for pulmonary vein isolation in patients with paroxysmal atrial fibrillation.
    Kottmaier M; Popa M; Bourier F; Reents T; Cifuentes J; Semmler V; Telishevska M; Otgonbayar U; Koch-Büttner K; Lennerz C; Bartkowiak M; Kornmayer M; Rousseva E; Brkic A; Grebmer C; Kolb C; Hessling G; Deisenhofer I
    Europace; 2020 Mar; 22(3):388-393. PubMed ID: 31872249
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Esophageal Endoscopy After Catheter Ablation of Atrial Fibrillation Using Ablation-Index Guided High-Power: Frankfurt AI-HP ESO-I.
    Chen S; Chun KRJ; Tohoku S; Bordignon S; Urbanek L; Willems F; Plank K; Hilbert M; Konstantinou A; Tsianakas N; Bologna F; Kreuzer C; Trolese L; Schmidt B
    JACC Clin Electrophysiol; 2020 Oct; 6(10):1253-1261. PubMed ID: 33092751
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.