These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

102 related articles for article (PubMed ID: 3363642)

  • 1. Therapeutic drug monitoring of cyclosporine by high-performance liquid chromatography in high volume.
    Vine W; Olson KN; Bowers LD
    Transplant Proc; 1988 Apr; 20(2 Suppl 2):354-6. PubMed ID: 3363642
    [No Abstract]   [Full Text] [Related]  

  • 2. Cyclosporine monitoring in kidney and liver transplant patients: comparison between radioimmunoassay (37 degrees C plasma) and high-performance liquid chromatography (whole blood) measurements.
    Mojaverian P; Green PJ
    Transplant Proc; 1988 Apr; 20(2 Suppl 2):414-8. PubMed ID: 3284085
    [No Abstract]   [Full Text] [Related]  

  • 3. Fast and specific measurement of cyclosporine A blood levels: a reliable high-performance liquid chromatography method.
    Wilms HW; Lison AE
    Transplant Proc; 1988 Apr; 20(2 Suppl 2):357-60. PubMed ID: 3363643
    [No Abstract]   [Full Text] [Related]  

  • 4. [Drug monitoring of cyclosporin by using high-performance liquid chromatography].
    Sewing KF; Christians U; Bleck JS; Strohmeyer S; Beil W; Kohlhaw K; Wonigeit K
    Dtsch Med Wochenschr; 1988 Feb; 113(8):311-4. PubMed ID: 3277835
    [No Abstract]   [Full Text] [Related]  

  • 5. Screening for abnormal cyclosporine A metabolite concentrations.
    Offermann G; Brockmöller J; Kunzendorf U; Roots I
    Transplant Proc; 1989 Feb; 21(1 Pt 1):892-4. PubMed ID: 2650291
    [No Abstract]   [Full Text] [Related]  

  • 6. Cyclosporine measurement in transplantation.
    Sanghvi A; Seltman H; Diven W
    Arch Pathol Lab Med; 1985 Dec; 109(12):1072-5. PubMed ID: 3907588
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Fully automated high-performance liquid chromatographic determination using pretreatment polymer column and column-switching for fast, daily, routine bedside monitoring of cyclosporine in whole blood.
    Uchida K; Yamada N; Orihara A; Tominaga Y; Tanaka Y; Hayashi S; Kondo T; Nishikawa Y; Morozumi K; Satake M
    Transplant Proc; 1989 Feb; 21(1 Pt 1):901-3. PubMed ID: 2705254
    [No Abstract]   [Full Text] [Related]  

  • 8. [Determination of cyclosporine in whole blood by reversed phase high performance liquid chromatography].
    Liu XJ; Tao CH; Chen HX; Wang W
    Yao Xue Xue Bao; 1988 May; 23(5):397-400. PubMed ID: 3213523
    [No Abstract]   [Full Text] [Related]  

  • 9. Cyclosporine: experience with therapeutic monitoring.
    Bowers LD; Canafax DM
    Ther Drug Monit; 1984; 6(2):142-7. PubMed ID: 6377597
    [No Abstract]   [Full Text] [Related]  

  • 10. Cyclosporine A monitoring by radioimmunoassay (RIA) and high-performance liquid chromatography (HPLC) after liver transplantation: influence of route of administration and of liver function on the RIA:HPLC ratio.
    Oldhafer KJ; Schumann G; Wonigeit K; Oellerich M; Ringe B; Pichlmayr R
    Transplant Proc; 1988 Jun; 20(3 Suppl 3):361-5. PubMed ID: 3291268
    [No Abstract]   [Full Text] [Related]  

  • 11. [A rapid method for the determination of cyclosporin A in blood by high performance liquid chromatography].
    Toulet V; Saux MC; Rouquette C; Penouil F; Brachet-Liermain A
    Ann Biol Clin (Paris); 1986; 44(5):517-21. PubMed ID: 3813137
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Blood cyclosporine: which assay is advised?].
    Feutren G; Humbert H
    Nephrologie; 1988; 9(5):197-9. PubMed ID: 3063987
    [No Abstract]   [Full Text] [Related]  

  • 13. The measurement of cyclosporine A and metabolite M17 in whole blood by high-performance liquid chromatography.
    Roberts NB; Lane C; Scott MH; Sells RA
    Transplant Proc; 1988 Apr; 20(2 Suppl 2):625-32. PubMed ID: 3284112
    [No Abstract]   [Full Text] [Related]  

  • 14. Cyclosporine analysis by high-performance liquid chromatography: precision, accuracy, and minimum detectable quantity.
    Bowers LD
    Transplant Proc; 1990 Jun; 22(3):1150-4. PubMed ID: 2349677
    [No Abstract]   [Full Text] [Related]  

  • 15. Monitoring cyclosporine therapy.
    Burckart GJ
    Clin Pharm; 1983; 2(6):568. PubMed ID: 6653058
    [No Abstract]   [Full Text] [Related]  

  • 16. Cyclosporine in auxiliary partial liver transplantation.
    de Rave S; Schalm SW; Willemse PJ; Weimar W; Terpstra OT
    Transplant Proc; 1988 Jun; 20(3 Suppl 3):397-400. PubMed ID: 3291275
    [No Abstract]   [Full Text] [Related]  

  • 17. Comparison and correlation of assays for monitoring cyclosporine drug levels in renal transplant recipients.
    Gibbons S; Grevel J; Reynolds K; Ried M; Rutzky LP; Kahan BD
    Transplant Proc; 1988 Apr; 20(2 Suppl 2):339-44. PubMed ID: 3284077
    [No Abstract]   [Full Text] [Related]  

  • 18. Monitoring of cyclosporine: a status report.
    Ther Drug Monit; 1984; 6(3):371-4. PubMed ID: 6506142
    [No Abstract]   [Full Text] [Related]  

  • 19. Critical issues in cyclosporine monitoring: report of the Task Force on Cyclosporine Monitoring.
    Clin Chem; 1987 Jul; 33(7):1269-88. PubMed ID: 3297427
    [No Abstract]   [Full Text] [Related]  

  • 20. Measurement of blood cyclosporine metabolite concentrations with a new column-switching high-performance liquid chromatographic assay.
    Yee GC; Gmur DJ; Meier P
    Transplant Proc; 1988 Apr; 20(2 Suppl 2):585-90. PubMed ID: 3363657
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.