128 related articles for article (PubMed ID: 33636827)
1. Sample Type and Storage Conditions Affect Calprotectin Measurements in Blood.
Pedersen L; Birkemose E; Gils C; Safi S; Nybo M
J Appl Lab Med; 2018 May; 2(6):851-856. PubMed ID: 33636827
[TBL] [Abstract][Full Text] [Related]
2. Glucose variation in centrifuged serum and lithium-heparin gel tubes stored for up to 96 hours at room temperature or 4 °C.
Balboni F; Burbui S; Lippi G
Scand J Clin Lab Invest; 2018; 78(7-8):546-550. PubMed ID: 30755098
[TBL] [Abstract][Full Text] [Related]
3. Five days serum glucose stability at room-temperature in centrifuged fast-clotting serum tubes and the comparability with glucose in heparin-plasma and plasma containing citrate-stabilizer.
Bakkebø H; Haaland KL; Hoff KS; Schwettmann L
Scand J Clin Lab Invest; 2024 Feb; 84(1):62-67. PubMed ID: 38451167
[TBL] [Abstract][Full Text] [Related]
4. Use of different anticoagulants in test tubes for analysis of blood lactate concentrations: Part 2. Implications for the proper handling of blood specimens obtained from critically ill patients.
Wiese J; Didwania A; Kerzner R; Chernow B
Crit Care Med; 1997 Nov; 25(11):1847-50. PubMed ID: 9366768
[TBL] [Abstract][Full Text] [Related]
5. Effect of collection tube type and preanalytical handling on myeloperoxidase concentrations.
Shih J; Datwyler SA; Hsu SC; Matias MS; Pacenti DP; Lueders C; Mueller C; Danne O; Möckel M
Clin Chem; 2008 Jun; 54(6):1076-9. PubMed ID: 18509013
[TBL] [Abstract][Full Text] [Related]
6. Plasma calprotectin - preanalytical stability and interference from hemolysis.
Blavnsfeldt AG; Parkner T; Knudsen CS
Scand J Clin Lab Invest; 2022 Sep; 82(5):349-355. PubMed ID: 35822403
[TBL] [Abstract][Full Text] [Related]
7. Effects of blood sample collection and preparation methods on concentrations of glucose and nonesterified fatty acids in dairy cattle.
Drackley JK
JDS Commun; 2023 Nov; 4(6):454-457. PubMed ID: 38045888
[TBL] [Abstract][Full Text] [Related]
8. A determination of the pre-analytical storage conditions for insulin like growth factor-I and type III procollagen peptide.
Holt RI; Erotokritou-Mulligan I; Ridley SA; McHugh CM; Bassett EE; Cowan DA; Bartlett C; Sönksen PH
Growth Horm IGF Res; 2009 Feb; 19(1):43-50. PubMed ID: 18617430
[TBL] [Abstract][Full Text] [Related]
9. Temporal effects of 3 commonly used anticoagulants on hematologic and biochemical variables in blood samples from macaws and Burmese pythons.
Harr KE; Raskin RE; Heard DJ
Vet Clin Pathol; 2005 Dec; 34(4):383-8. PubMed ID: 16270264
[TBL] [Abstract][Full Text] [Related]
10. Circulating calprotectin as biomarker in neutrophil-related inflammation: Pre-analytical recommendations and reference values according to sample type.
Mylemans M; Nevejan L; Van Den Bremt S; Stubbe M; Cruyssen BV; Moulakakis C; Berthold H; Konrad C; Bossuyt X; Van Hoovels L
Clin Chim Acta; 2021 Jun; 517():149-155. PubMed ID: 33689693
[TBL] [Abstract][Full Text] [Related]
11. Measuring calprotectin in plasma and blood with a fully automated turbidimetric assay.
Åsberg A; Løfblad L; Felic A; Hov GG
Scand J Clin Lab Invest; 2019; 79(1-2):50-57. PubMed ID: 30761918
[TBL] [Abstract][Full Text] [Related]
12. Influence of the sample matrix on the stability of beta-CTX at room temperature for 24 and 48 hours.
Lippi G; Brocco G; Salvagno GL; Montagnana M; Guidi GC; Schmidt-Gayk H
Clin Lab; 2007; 53(7-8):455-9. PubMed ID: 17821951
[TBL] [Abstract][Full Text] [Related]
13. Evaluation of the automated hematology analyzer Sysmex XT-2000iV ™ compared to the ADVIA ® 2120 for its use in dogs, cats, and horses. Part II: Accuracy of leukocyte differential and reticulocyte count, impact of anticoagulant and sample aging.
Bauer N; Nakagawa J; Dunker C; Failing K; Moritz A
J Vet Diagn Invest; 2012 Jan; 24(1):74-89. PubMed ID: 22362937
[TBL] [Abstract][Full Text] [Related]
14. Instability of IGF-IGFBP complex as a cause of the different performance of serum and EDTA-plasma after storage: EDTA-plasma is preferable for evaluating bioactive IGF especially in the mouse.
Setoyama T; Miyamoto S; Nikaido M; Muto M; Chiba T
Growth Horm IGF Res; 2015 Oct; 25(5):227-31. PubMed ID: 26144570
[TBL] [Abstract][Full Text] [Related]
15. Technical note: Effect of storage time and temperature on total calcium concentrations in bovine blood.
Bach KD; Neves RC; Stokol T; McArt JAA
J Dairy Sci; 2020 Jan; 103(1):922-928. PubMed ID: 31733856
[TBL] [Abstract][Full Text] [Related]
16. Impact of blood cell counts and volumes on glucose concentration in uncentrifuged serum and lithium-heparin blood tubes.
Lippi G; Salvagno GL; Lampus S; Danese E; Gelati M; Bovo C; Montagnana M; Simundic AM
Clin Chem Lab Med; 2018 Nov; 56(12):2125-2131. PubMed ID: 29935113
[TBL] [Abstract][Full Text] [Related]
17. Stability of antioxidant vitamins in whole human blood during overnight storage at 4°C and frozen storage up to 6 months.
Leonard SW; Bobe G; Traber MG
Int J Vitam Nutr Res; 2018 Jun; 88(3-4):151-157. PubMed ID: 30747603
[No Abstract] [Full Text] [Related]
18. Heparin plasma sampling as an alternative to EDTA for BNP determination on the Access-Beckman Coulter--effect of storage at -20 degrees C.
Dupuy AM; Terrier N; Dubois M; Boularan AM; Cristol JP
Clin Lab; 2006; 52(7-8):393-7. PubMed ID: 16955639
[TBL] [Abstract][Full Text] [Related]
19. Influence of sample matrix and storage on BNP measurement on the Bayer Advia Centaur.
Lippi G; Fortunato A; Salvagno GL; Montagnana M; Soffiati G; Guidi GC
J Clin Lab Anal; 2007; 21(5):293-7. PubMed ID: 17847103
[TBL] [Abstract][Full Text] [Related]
20. Aspects of preanalytical variation of lactoferrin and elastase/alpha 1-protease inhibitor complexes.
Antonsen S; Qvist N; Wanscher M
Scand J Clin Lab Invest; 1993 May; 53(3):263-74. PubMed ID: 8316754
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]