215 related articles for article (PubMed ID: 33641537)
1. Usefulness of the obturator hook technique for guiding the initial trajectory control in infra-acetabular screw placement.
Lim EJ; Sakong S; Son WS; Kim H; Cho JW; Oh JK
J Orthop Surg (Hong Kong); 2021; 29(1):2309499021996838. PubMed ID: 33641537
[TBL] [Abstract][Full Text] [Related]
2. Which radiograph is most accurate for assessing hip joint penetration in infra-acetabular screw placement?
Lim EJ; Sakong S; Choi W; Oh JK; Cho JW
Medicine (Baltimore); 2021 Jun; 100(24):e26392. PubMed ID: 34128903
[TBL] [Abstract][Full Text] [Related]
3. [Single cannulated screws for stabilisation of pelvic ring and acetabular fractures].
Taller S; Lukáš R; Srám J
Acta Chir Orthop Traumatol Cech; 2011; 78(6):568-77. PubMed ID: 22217412
[TBL] [Abstract][Full Text] [Related]
4. [Orthopedic robot based on 5G technology for remote navigation of percutaneous screw fixation in pelvic and acetabular fractures].
Zhao B; Li J; Zhao C; Su Y; Han W; Wu X; Jiang X; Wang J
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2022 Aug; 36(8):923-928. PubMed ID: 35979780
[TBL] [Abstract][Full Text] [Related]
5. Ideal insertion point and projection of the infra-acetabular screw in acetabular fracture surgery.
Fukuoka S; Yorimitsu M; Uehara T; Naniwa S; Hata T; Sato K; Noda T; Sato T; Ozaki T
Injury; 2024 Jun; 55(6):111264. PubMed ID: 38105150
[TBL] [Abstract][Full Text] [Related]
6. The obturator oblique and iliac oblique/outlet views predict most accurately the adequate position of an anterior column acetabular screw.
Guimarães JAM; Martin MP; da Silva FR; Duarte MEL; Cavalcanti ADS; Machado JAP; Mauffrey C; Rojas D
Int Orthop; 2019 May; 43(5):1205-1213. PubMed ID: 29948010
[TBL] [Abstract][Full Text] [Related]
7. CT-guided fixation of pelvic fractures after high-energy trauma, by interventional radiologists: technical and clinical outcome.
Dekimpe C; Andreani O; De Dompsure RB; Lemmex DB; Layet V; Foti P; Amoretti N
Eur Radiol; 2020 Feb; 30(2):961-970. PubMed ID: 31628504
[TBL] [Abstract][Full Text] [Related]
8. A guideline for placement of an infra-acetabular screw based on anatomic landmarks via an intra-pelvic approach.
Baumann F; Schmitz P; Mahr D; Kerschbaum M; Gänsslen A; Nerlich M; Worlicek M
J Orthop Surg Res; 2018 Apr; 13(1):77. PubMed ID: 29631637
[TBL] [Abstract][Full Text] [Related]
9. Optimizing percutaneous reduction and fixation with guidewire modification in pelvic and acetabular fractures: surgical technique and case series.
Mudawi A; Alzobi O; Derbas JN; Ahmed G; Abousamhadaneh M
Eur J Orthop Surg Traumatol; 2024 May; 34(4):2107-2112. PubMed ID: 38548873
[TBL] [Abstract][Full Text] [Related]
10. [A clinical study of HoloSight Orthopaedic Trauma Surgery Robot-assisted infra-acetabular screw placement for acetabular fractures].
Cao W; Wang Z; Li J; Qi L; Qi H; He P; He J; Liu H; Yi C; Chen H
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2024 Jun; 38(6):696-702. PubMed ID: 38918190
[TBL] [Abstract][Full Text] [Related]
11. The 'safe zone' for extra-articular screw placement during intra-pelvic acetabular surgery.
Guy P; Al-Otaibi M; Harvey EJ; Helmy N
J Orthop Trauma; 2010 May; 24(5):279-83. PubMed ID: 20418732
[TBL] [Abstract][Full Text] [Related]
12. Infra-acetabular corridor--technical tip for an additional screw placement to increase the fixation strength of acetabular fractures.
Culemann U; Marintschev I; Gras F; Pohlemann T
J Trauma; 2011 Jan; 70(1):244-6. PubMed ID: 21217495
[No Abstract] [Full Text] [Related]
13. Analysis of computed tomography-based infra-acetabular morphometry to assess the feasibility of infra-acetabular screws.
Kanezaki S; Miyazaki M; Notani N; Ishihara T; Sakamoto T; Abe T; Kataoka M; Tsumura H
Arch Orthop Trauma Surg; 2020 Mar; 140(3):359-364. PubMed ID: 31598759
[TBL] [Abstract][Full Text] [Related]
14. Screw- versus plate-fixation strength of acetabular anterior column fractures: a biomechanical study.
Gras F; Marintschev I; Schwarz CE; Hofmann GO; Pohlemann T; Culemann U
J Trauma Acute Care Surg; 2012 Jun; 72(6):1664-70. PubMed ID: 22695438
[TBL] [Abstract][Full Text] [Related]
15. Fluoroscopically assisted computer navigation enables accurate percutaneous screw placement for pelvic and acetabular fracture fixation.
Wong JM; Bewsher S; Yew J; Bucknill A; de Steiger R
Injury; 2015; 46(6):1064-8. PubMed ID: 25683211
[TBL] [Abstract][Full Text] [Related]
16. Intraoperative fluoroscopic evaluation of screw placement during pelvic and acetabular surgery.
Yi C; Burns S; Hak DJ
J Orthop Trauma; 2014 Jan; 28(1):48-56. PubMed ID: 23360910
[TBL] [Abstract][Full Text] [Related]
17. [Percutaneous fixation of anterior column acetabular fractures--first experience].
Frank M; Dedek T; Trlica J; Folvarský J
Acta Chir Orthop Traumatol Cech; 2010 Apr; 77(2):99-104. PubMed ID: 20447351
[TBL] [Abstract][Full Text] [Related]
18. Percutaneous screw fixation of acetabular fractures with 2D fluoroscopy-based computerized navigation.
Hong G; Cong-Feng L; Cheng-Fang H; Chang-Qing Z; Bing-Fang Z
Arch Orthop Trauma Surg; 2010 Sep; 130(9):1177-83. PubMed ID: 20364263
[TBL] [Abstract][Full Text] [Related]
19. Biomechanical comparison of different acetabular plate systems and constructs--the role of an infra-acetabular screw placement and use of locking plates.
Marintschev I; Gras F; Schwarz CE; Pohlemann T; Hofmann GO; Culemann U
Injury; 2012 Apr; 43(4):470-4. PubMed ID: 22261082
[TBL] [Abstract][Full Text] [Related]
20. Posterior acetabular wall fractures: a technique for screw placement.
Bosse MJ
J Orthop Trauma; 1991; 5(2):167-72. PubMed ID: 1861192
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]