These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

123 related articles for article (PubMed ID: 33643457)

  • 61. The Phenomenon of the Apparent (Double) Femoral Head in Infant Hip Sonography According to Graf-Description, Incidence and Clinical Relevance.
    Struwe C; Bornemann R; Walter SG; Koob S; Placzek R
    Z Orthop Unfall; 2020 Oct; 158(5):462-465. PubMed ID: 31634952
    [TBL] [Abstract][Full Text] [Related]  

  • 62. [Development of Hip Joints Treated Non-operatively for Developmental Dysplasia of the Hip by Overhead Traction - Clinical and Radiographic Assessment after Reaching Skeletal Maturity].
    Valtr O; Šponer P; Pellar D; KuČera T
    Acta Chir Orthop Traumatol Cech; 2020; 87(6):381-386. PubMed ID: 33536116
    [TBL] [Abstract][Full Text] [Related]  

  • 63. [Sonographic follow-up of hip dysplasia treated with an abduction brace].
    Eller K; Katthagen BD
    Z Orthop Ihre Grenzgeb; 1987; 125(5):534-41. PubMed ID: 3324535
    [TBL] [Abstract][Full Text] [Related]  

  • 64. Late presentation of developmental dysplasia of the hip : a 15-year observational study.
    Talbot C; Adam J; Paton R
    Bone Joint J; 2017 Sep; 99-B(9):1250-1255. PubMed ID: 28860408
    [TBL] [Abstract][Full Text] [Related]  

  • 65. Results of universal ultrasound screening for developmental dysplasia of the hip: a prospective follow-up of 28 092 consecutive infants.
    Biedermann R; Riccabona J; Giesinger JM; Brunner A; Liebensteiner M; Wansch J; Dammerer D; Nogler M
    Bone Joint J; 2018 Oct; 100-B(10):1399-1404. PubMed ID: 30295526
    [TBL] [Abstract][Full Text] [Related]  

  • 66. Pavlik harness and Frejka pillow: compliance affects results of outpatient treatment.
    Zídka M; Džupa V
    Arch Orthop Trauma Surg; 2019 Nov; 139(11):1519-1524. PubMed ID: 30937524
    [TBL] [Abstract][Full Text] [Related]  

  • 67. Comparison between Graf method and pubo-femoral distance in neutral and flexion positions to diagnose developmental dysplasia of the hip.
    Teixeira SR; Dalto VF; Maranho DA; Zoghbi-Neto OS; Volpon JB; Nogueira-Barbosa MH
    Eur J Radiol; 2015 Feb; 84(2):301-6. PubMed ID: 25476594
    [TBL] [Abstract][Full Text] [Related]  

  • 68. [Paediatric hip sonography: current status at German university hospitals].
    Peterlein CD; Fuchs-Winkelmann S
    Orthopade; 2014 Feb; 43(2):136-42. PubMed ID: 24504624
    [TBL] [Abstract][Full Text] [Related]  

  • 69. Universal or selective screening of the neonatal hip using ultrasound? A prospective, randomised trial of 15,529 newborn infants.
    Holen KJ; Tegnander A; Bredland T; Johansen OJ; Saether OD; Eik-Nes SH; Terjesen T
    J Bone Joint Surg Br; 2002 Aug; 84(6):886-90. PubMed ID: 12211684
    [TBL] [Abstract][Full Text] [Related]  

  • 70. Early radiological outcome of ultrasound monitoring in infants with developmental dysplasia of the hips.
    Dornacher D; Cakir B; Reichel H; Nelitz M
    J Pediatr Orthop B; 2010 Jan; 19(1):27-31. PubMed ID: 19829154
    [TBL] [Abstract][Full Text] [Related]  

  • 71. Should paediatricians initiate orthopaedic hip dysplasia referrals for infants with isolated asymmetric skin folds?
    Louer CR; Bomar JD; Pring ME; Mubarak SJ; Upasani VV; Wenger DR
    J Child Orthop; 2019 Dec; 13(6):593-599. PubMed ID: 31908676
    [TBL] [Abstract][Full Text] [Related]  

  • 72. Is it worthwhile to screen the hip in infants born with clubfeet?
    Zhao D; Rao W; Zhao L; Liu J; Chen Y; Shen P; Du Q; Li L
    Int Orthop; 2013 Dec; 37(12):2415-20. PubMed ID: 24005238
    [TBL] [Abstract][Full Text] [Related]  

  • 73. Reproducibility of acquiring ultrasonographic infant hip images by the Graf method after an infant hip ultrasound training course.
    Shirai Y; Wakabayashi K; Wada I; Goto H; Ueki Y; Tsuchiya A; Tsuboi Y; Ha M; Otsuka T
    J Med Ultrason (2001); 2018 Oct; 45(4):583-589. PubMed ID: 29524009
    [TBL] [Abstract][Full Text] [Related]  

  • 74. [Treatment of borderline D/IIIa hip in newborn infants with the Graf-Mittelmeier abduction harness under close ultrasound control].
    Schmitz A; Wagner UA; Schmitt O
    Z Orthop Ihre Grenzgeb; 1999; 137(5):400-2. PubMed ID: 10549115
    [TBL] [Abstract][Full Text] [Related]  

  • 75. Diagnostic accuracy of static graf technique of ultrasound evaluation of infant hips for developmental dysplasia.
    Pillai A; Joseph J; McAuley A; Bramley D
    Arch Orthop Trauma Surg; 2011 Jan; 131(1):53-8. PubMed ID: 20379825
    [TBL] [Abstract][Full Text] [Related]  

  • 76. Orthopedic and ultrasound assessment of hip stability of newborns referred by pediatricians with suspected Developmental Dysplasia.
    Cruz MAF; Volpon JB
    Rev Col Bras Cir; 2020; 46(6):e20192284. PubMed ID: 32022108
    [TBL] [Abstract][Full Text] [Related]  

  • 77. Is 'clicky hip' a risk factor in developmental dysplasia of the hip?
    Kamath S; Bramley D
    Scott Med J; 2005 May; 50(2):56-8. PubMed ID: 15977515
    [TBL] [Abstract][Full Text] [Related]  

  • 78. Ultrasonographic Graf type IIa hip needs more consideration in newborn girls.
    Omeroğlu H; Caylak R; Inan U; Köse N
    J Child Orthop; 2013 Mar; 7(2):95-8. PubMed ID: 24432065
    [TBL] [Abstract][Full Text] [Related]  

  • 79. Developmental dysplasia of the hip.
    Aronsson DD; Goldberg MJ; Kling TF; Roy DR
    Pediatrics; 1994 Aug; 94(2 Pt 1):201-8. PubMed ID: 8036074
    [TBL] [Abstract][Full Text] [Related]  

  • 80. Ultrasound screening for developmental dysplasia of the hip after 4 weeks increases exam accuracy and decreases follow-up visits.
    Lussier EC; Sun YT; Chen HW; Chang TY; Chang CH
    Pediatr Neonatol; 2019 Jun; 60(3):270-277. PubMed ID: 30143415
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.