BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

165 related articles for article (PubMed ID: 33647910)

  • 21. Characterizing Insertion Pressure Profiles During Cochlear Implantation: Simultaneous Fluoroscopy and Intracochlear Pressure Measurements.
    Gonzalez JR; Cass ND; Banakis Hartl RM; Peacock J; Cass SP; Greene NT
    Otol Neurotol; 2020 Jan; 41(1):e46-e54. PubMed ID: 31613835
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Variance of angular insertion depths in free-fitting and perimodiolar cochlear implant electrodes.
    Radeloff A; Mack M; Baghi M; Gstoettner WK; Adunka OF
    Otol Neurotol; 2008 Feb; 29(2):131-6. PubMed ID: 18090204
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Real-Time Intracochlear Electrocochleography Obtained Directly Through a Cochlear Implant.
    Harris MS; Riggs WJ; Koka K; Litvak LM; Malhotra P; Moberly AC; O'Connell BP; Holder J; Di Lella FA; Boccio CM; Wanna GB; Labadie RF; Adunka OF
    Otol Neurotol; 2017 Jul; 38(6):e107-e113. PubMed ID: 28498269
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Electrode design and insertional depth-dependent intra-cochlear pressure changes: a model experiment.
    Mittmann P; Ernst A; Todt I
    J Laryngol Otol; 2018 Mar; 132(3):224-229. PubMed ID: 29103379
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Evaluation of Intracochlear Trauma Caused by Insertion of Cochlear Implant Electrode Arrays through Different Quadrants of the Round Window.
    Martins Gde S; Brito Neto RV; Tsuji RK; Gebrim EM; Bento RF
    Biomed Res Int; 2015; 2015():236364. PubMed ID: 26236719
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Relations Between Scalar Shift and Insertion Depth in Human Cochlear Implantation.
    Zelener F; Majdani O; Roemer A; Lexow GJ; Giesemann A; Lenarz T; Warnecke A
    Otol Neurotol; 2020 Feb; 41(2):178-185. PubMed ID: 31789806
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Uncovering Vulnerable Phases in Cochlear Implant Electrode Array Insertion: Insights from an In Vitro Model.
    Aebischer P; Weder S; Vischer M; Mantokoudis G; Caversaccio M; Wimmer W
    Otol Neurotol; 2024 Apr; 45(4):e271-e280. PubMed ID: 38346807
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Simultaneous Intra- and Extracochlear Electrocochleography During Electrode Insertion.
    Dalbert A; Sijgers L; Grosse J; Veraguth D; Roosli C; Huber A; Pfiffner F
    Ear Hear; 2021; 42(2):414-424. PubMed ID: 32826509
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Evaluating Intracochlear Trauma after Cochlear Implant Electrode Insertion through Middle Fossa Approach in Temporal Bones.
    Cisneros Lesser JC; de Brito R; Queiroz Martins GS; Gebrim EMMS; Bento RF
    Otolaryngol Head Neck Surg; 2018 Feb; 158(2):350-357. PubMed ID: 29088548
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Four-Point Impedance Changes After Cochlear Implantation for Lateral Wall and Perimodiolar Implants.
    Razmovski T; Bester C; Collins A; Tan E; O'Leary SJ
    Otol Neurotol; 2022 Dec; 43(10):e1107-e1114. PubMed ID: 36351225
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Intracochlear pressure changes due to round window opening: a model experiment.
    Mittmann P; Ernst A; Todt I
    ScientificWorldJournal; 2014; 2014():341075. PubMed ID: 24982942
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Patterns Seen During Electrode Insertion Using Intracochlear Electrocochleography Obtained Directly Through a Cochlear Implant.
    Harris MS; Riggs WJ; Giardina CK; O'Connell BP; Holder JT; Dwyer RT; Koka K; Labadie RF; Fitzpatrick DC; Adunka OF
    Otol Neurotol; 2017 Dec; 38(10):1415-1420. PubMed ID: 28953607
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Postinsertional Cable Movements of Cochlear Implant Electrodes and Their Effects on Intracochlear Pressure.
    Todt I; Karimi D; Luger J; Ernst A; Mittmann P
    Biomed Res Int; 2016; 2016():3937196. PubMed ID: 27900329
    [No Abstract]   [Full Text] [Related]  

  • 34. Influence of Intracochlear Air on Experimental Pressure Measurements.
    Riemann C; Sudhoff H; Todt I
    Audiol Neurootol; 2022; 27(1):34-39. PubMed ID: 34130281
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Evaluation of Insertion Forces and Cochlea Trauma Following Robotics-Assisted Cochlear Implant Electrode Array Insertion.
    Kaufmann CR; Henslee AM; Claussen A; Hansen MR
    Otol Neurotol; 2020 Jun; 41(5):631-638. PubMed ID: 32604327
    [TBL] [Abstract][Full Text] [Related]  

  • 36. The pattern and degree of capsular fibrous sheaths surrounding cochlear electrode arrays.
    Ishai R; Herrmann BS; Nadol JB; Quesnel AM
    Hear Res; 2017 May; 348():44-53. PubMed ID: 28216124
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Hearing Preservation With a New Atraumatic Lateral Wall Electrode.
    Lenarz T; Buechner A; Lesinski-Schiedat A; Timm M; Salcher R
    Otol Neurotol; 2020 Sep; 41(8):e993-e1003. PubMed ID: 32569147
    [TBL] [Abstract][Full Text] [Related]  

  • 38. A model for cochlear implant electrode insertion and force evaluation: results with a new electrode design and insertion technique.
    Roland JT
    Laryngoscope; 2005 Aug; 115(8):1325-39. PubMed ID: 16094101
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Intracochlear Trauma and Local Ossification Patterns Differ Between Straight and Precurved Cochlear Implant Electrodes.
    Geerardyn A; Zhu M; Verhaert N; Quesnel AM
    Otol Neurotol; 2024 Mar; 45(3):245-255. PubMed ID: 38270168
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Potential insertion complications with cochlear implant electrodes.
    Ishiyama A; Risi F; Boyd P
    Cochlear Implants Int; 2020 Jul; 21(4):206-219. PubMed ID: 32079506
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.