These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 33648071)

  • 1. Design of modular multi-channel electron spectrometers for application in laser matter interaction experiments at Prague Asterix Laser System.
    Krupka M; Singh S; Pisarczyk T; Dostal J; Kalal M; Krasa J; Dudzak R; Burian T; Jelinek S; Chodukowski T; Rusiniak Z; Krus M; Juha L
    Rev Sci Instrum; 2021 Feb; 92(2):023514. PubMed ID: 33648071
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Design and calibration of hot-electron spectrometer array for angle-resolved measurement.
    Liu H; An H; Shen J; Kang N; Zhou S; Lei A; Lin Z
    Rev Sci Instrum; 2017 May; 88(5):053507. PubMed ID: 28571400
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A compact, multiangle electron spectrometer for ultraintense laser-plasma interaction experiments.
    Gotchev OV; Brijesh P; Nilson PM; Stoeckl C; Meyerhofer DD
    Rev Sci Instrum; 2008 May; 79(5):053505. PubMed ID: 18513067
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Photon beams for radiosurgery produced by laser Compton backscattering from relativistic electrons.
    Girolami B; Larsson B; Preger M; Schaerf C; Stepanek J
    Phys Med Biol; 1996 Sep; 41(9):1581-96. PubMed ID: 8884899
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Multi-resolution electron spectrometer array for future free-electron laser experiments.
    Walter P; Kamalov A; Gatton A; Driver T; Bhogadi D; Castagna JC; Cheng X; Shi H; Obaid R; Cryan J; Helml W; Ilchen M; Coffee RN
    J Synchrotron Radiat; 2021 Sep; 28(Pt 5):1364-1376. PubMed ID: 34475285
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A ten-inch manipulator (TIM) based fast-electron spectrometer with multiple viewing angles (OU-ESM).
    Habara H; Iwawaki T; Gong T; Wei MS; Ivancic ST; Theobald W; Krauland CM; Zhang S; Fiksel G; Tanaka KA
    Rev Sci Instrum; 2019 Jun; 90(6):063501. PubMed ID: 31255022
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A simple magnetic spectrometer for radiotherapy electron beams.
    Deasy JO; Almond PR; McEllistrem MT; Ross CK
    Med Phys; 1994 Nov; 21(11):1703-14. PubMed ID: 7891630
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Gradient magnet design for simultaneous detection of electrons and positrons in the intermediate MeV range.
    Tiwari G; Kupfer R; Jiao X; Gaul E; Hegelich BM
    Rev Sci Instrum; 2019 Aug; 90(8):083304. PubMed ID: 31472603
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Permanent-magnet energy spectrometer for electron beams from radiotherapy accelerators.
    McLaughlin DJ; Hogstrom KR; Carver RL; Gibbons JP; Shikhaliev PM; Matthews KL; Clarke T; Henderson A; Liang EP
    Med Phys; 2015 Sep; 42(9):5517-29. PubMed ID: 26328999
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Compact Thomson parabola spectrometer with variability of energy range and measurability of angular distribution for low-energy laser-driven accelerated ions.
    Kojima S; Inoue S; Dinh TH; Hasegawa N; Mori M; Sakaki H; Yamamoto Y; Sasaki T; Shiokawa K; Kondo K; Yamanaka T; Hashida M; Sakabe S; Nishikino M; Kondo K
    Rev Sci Instrum; 2020 May; 91(5):053305. PubMed ID: 32486709
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Compact high energy x-ray spectrometer based on forward Compton scattering for high intensity laser plasma experiments.
    Singh S; Versaci R; Laso Garcia A; Morejon L; Ferrari A; Molodtsova M; Schwengner R; Kumar D; Cowan T
    Rev Sci Instrum; 2018 Aug; 89(8):085118. PubMed ID: 30184659
    [TBL] [Abstract][Full Text] [Related]  

  • 12. An angular-resolved multi-channel Thomson parabola spectrometer for laser-driven ion measurement.
    Zhang Y; Zhang Z; Zhu B; Jiang W; Cheng L; Zhao L; Zhang X; Zhao X; Yuan X; Tong B; Zhong J; He S; Lu F; Wu Y; Zhou W; Zhang F; Zhou K; Xie N; Huang Z; Gu Y; Weng S; Xu M; Li Y; Li Y
    Rev Sci Instrum; 2018 Sep; 89(9):093302. PubMed ID: 30278712
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Compact multichannel spectrometer employed for soft x-ray spectrum diagnostics at the Shenguang-III Laser Facility.
    Liu H; Mu B; Liu S; Xie X; Che X; Xu J; Wang X; Chen L; Li W; Shi K; Ding Y
    Opt Express; 2022 Dec; 30(25):45792-45806. PubMed ID: 36522976
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A practical superconducting-microcalorimeter X-ray spectrometer for beamline and laboratory science.
    Doriese WB; Abbamonte P; Alpert BK; Bennett DA; Denison EV; Fang Y; Fischer DA; Fitzgerald CP; Fowler JW; Gard JD; Hays-Wehle JP; Hilton GC; Jaye C; McChesney JL; Miaja-Avila L; Morgan KM; Joe YI; O'Neil GC; Reintsema CD; Rodolakis F; Schmidt DR; Tatsuno H; Uhlig J; Vale LR; Ullom JN; Swetz DS
    Rev Sci Instrum; 2017 May; 88(5):053108. PubMed ID: 28571411
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A novel approach to electron data background treatment in an online wide-angle spectrometer for laser-accelerated ion and electron bunches.
    Lindner FH; Bin JH; Englbrecht F; Haffa D; Bolton PR; Gao Y; Hartmann J; Hilz P; Kreuzer C; Ostermayr TM; Rösch TF; Speicher M; Parodi K; Thirolf PG; Schreiber J
    Rev Sci Instrum; 2018 Jan; 89(1):013301. PubMed ID: 29390656
    [TBL] [Abstract][Full Text] [Related]  

  • 16. New magnetic electron spectrometer with directional sensitivity for a satellite application.
    Korth A; Wilken B
    Rev Sci Instrum; 1978 Oct; 49(10):1435. PubMed ID: 18698972
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of measured and calculated X-ray and hot-electron production in short-pulse laser-solid interactions at moderate intensities.
    Schlegel T; Bastiani S; Grémillet L; Geindre JP; Audebert P; Gauthier JC; Lefebvre E; Bonnaud G; Delettrez J
    Phys Rev E Stat Phys Plasmas Fluids Relat Interdiscip Topics; 1999 Aug; 60(2 Pt B):2209-17. PubMed ID: 11970015
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Design of a compact spectrometer for high-flux MeV gamma-ray beams.
    Corvan DJ; Sarri G; Zepf M
    Rev Sci Instrum; 2014 Jun; 85(6):065119. PubMed ID: 24985864
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Calculation of photon energy deposition kernels and electron dose point kernels in water.
    Mainegra-Hing E; Rogers DW; Kawrakow I
    Med Phys; 2005 Mar; 32(3):685-99. PubMed ID: 15839340
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Development of Compton X-ray spectrometer for high energy resolution single-shot high-flux hard X-ray spectroscopy.
    Kojima S; Ikenouchi T; Arikawa Y; Sakata S; Zhang Z; Abe Y; Nakai M; Nishimura H; Shiraga H; Ozaki T; Miyamoto S; Yamaguchi M; Takemoto A; Fujioka S; Azechi H
    Rev Sci Instrum; 2016 Apr; 87(4):043502. PubMed ID: 27131669
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.