These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

158 related articles for article (PubMed ID: 3364815)

  • 1. [Final arrest of a pacemaker after use of electrocautery].
    Delhumeau A; Ronceray S; Moreau X; Cottineau C; Cavellat M
    Ann Fr Anesth Reanim; 1988; 7(2):162-4. PubMed ID: 3364815
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Rapid ventricular pacing due to electrocautery: a case report and review.
    Wilson S; Neustein SN; Camunas J
    Mt Sinai J Med; 2006 Oct; 73(6):880-3. PubMed ID: 17117315
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Electrocautery-induced pacemaker malfunction during surgery.
    Mangar D; Atlas GM; Kane PB
    Can J Anaesth; 1991 Jul; 38(5):616-8. PubMed ID: 1934215
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Electrocautery-induced asystole in a scoliosis patient with a pacemaker.
    Bales JG; Colon J; Ramadhyani U; LeDoux E; Bennett JT
    J Pediatr Orthop B; 2007 Jan; 16(1):19-22. PubMed ID: 17159528
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Intraoperative pacemaker failure in an infant.
    Bailey AG; Lacey SR
    Can J Anaesth; 1991 Oct; 38(7):912-3. PubMed ID: 1742829
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Reprogramming of a pacemaker induced by electrocautery].
    Caramella JP; Mentre B; Jattiot F; Strouk R; Delétang D
    Ann Fr Anesth Reanim; 1987; 6(3):214-6. PubMed ID: 3619157
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Effects of electrocautery on the threshold values of permanent pacing. An experimental study].
    Chauvin M; Crenner F; Brechenmacher C
    Arch Mal Coeur Vaiss; 1992 Sep; 85(9):1323-7. PubMed ID: 1290394
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Anesthetic management for nephrectomy using a monopolar electrocautery in a patient implanted with a biventricular pacemaker].
    Takimoto K; Arai F; Kita T; Sasaki S
    Masui; 2009 Jan; 58(1):96-9. PubMed ID: 19175023
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Interaction between electrocautery and a pacemaker].
    Richard JP; Conil JM; Antonini A; Bareille P
    Ann Fr Anesth Reanim; 1986; 5(1):72-3. PubMed ID: 2422991
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Reversible prolonged pacemaker failure due to electrocautery.
    Peters RW; Gold MR
    J Interv Card Electrophysiol; 1998 Dec; 2(4):343-4. PubMed ID: 10027119
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Electromagnetic interference of an external temporary pacemaker during maxillofacial and neck surgery.
    Seo K; Takayama H; Araya Y; Miura K; Tanaka Y; Kobayashi Y; Someya G
    Anesth Prog; 1996; 43(2):64-6. PubMed ID: 10336403
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Electrocautery and pacemakers: management of the paced patient subject to electrocautery.
    Levine PA; Balady GJ; Lazar HL; Belott PH; Roberts AJ
    Ann Thorac Surg; 1986 Mar; 41(3):313-7. PubMed ID: 3954504
    [TBL] [Abstract][Full Text] [Related]  

  • 13. How pacemakers work and simple programming: a primer for the non-electrophysiologist.
    Chiu-Man C
    Cardiol Young; 2017 Jan; 27(S1):S115-S120. PubMed ID: 28084968
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Anesthesia and cardiac pacing].
    Caramella JP; Aliot E; Claude E
    Ann Fr Anesth Reanim; 1988; 7(4):309-19. PubMed ID: 3059853
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Interference between a dual-chamber pacemaker and argon electrocautery device during hepatectomy].
    Werner P; Charbit B; Samain E; Farah E; Marty J
    Ann Fr Anesth Reanim; 2001 Oct; 20(8):716-9. PubMed ID: 11695291
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Ventricular fibrillation induced by coagulating mode bipolar electrocautery during pacemaker implantation in Myotonic Dystrophy type 1 patient.
    Russo V; Rago A; DI Meo F; Cioppa ND; Papa AA; Russo MG; Nigro G
    Acta Myol; 2014 Dec; 33(3):149-51. PubMed ID: 25873784
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Upper limit ventricular stimulation in respiratory rate responsive pacing due to electrocautery.
    Van Hemel NM; Hamerlijnck RP; Pronk KJ; Van der Veen EP
    Pacing Clin Electrophysiol; 1989 Nov; 12(11):1720-3. PubMed ID: 2478969
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Permanent-temporary pacemakers in the management of patients with conduction abnormalities after transcatheter aortic valve replacement.
    Leong D; Sovari AA; Ehdaie A; Chakravarty T; Liu Q; Jilaihawi H; Makkar R; Wang X; Cingolani E; Shehata M
    J Interv Card Electrophysiol; 2018 Jun; 52(1):111-116. PubMed ID: 29532275
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [In vitro study of the effects of high frequency electrical current on cardiac pacemakers].
    Chauvin M; Crenner F; Brechenmacher C
    Arch Mal Coeur Vaiss; 1990 Jun; 83(7):997-1002. PubMed ID: 2114861
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The patient with a pacemaker or related device.
    Bourke ME
    Can J Anaesth; 1996 May; 43(5 Pt 2):R24-41. PubMed ID: 8706219
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.