These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

178 related articles for article (PubMed ID: 33651029)

  • 1. Mechanical Stability of Zirconia Implant Abutments Supporting Cantilevered Fixed Dental Prostheses After Fatigue Loading.
    Karasan D; Att W; Sailer I; Canay S
    Int J Prosthodont; 2021; 34(5):615–625. PubMed ID: 33651029
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Zirconia Cantilever Fixed Dental Prostheses Supported by One or Two Implants: An In Vitro Study on Mechanical Stability and Technical Outcomes.
    Karasan D; Canay S; Sailer I; Att W
    Int J Oral Maxillofac Implants; 2022; 37(4):748-755. PubMed ID: 35904831
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Fracture Resistance of Straight and Angulated Zirconia Implant Abutments Supporting Anterior Three-Unit Lithium Disilicate Fixed Dental Prostheses.
    Saker S; El-Shahat S; Ghazy M
    Int J Oral Maxillofac Implants; 2016; 31(6):1240-1246. PubMed ID: 27861648
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Fracture strength study of internally connected zirconia abutments reinforced with titanium inserts.
    Chun HJ; Yeo IS; Lee JH; Kim SK; Heo SJ; Koak JY; Han JS; Lee SJ
    Int J Oral Maxillofac Implants; 2015; 30(2):346-50. PubMed ID: 25830395
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Load fatigue performance of conical implant-abutment connections.
    Seetoh YL; Tan KB; Chua EK; Quek HC; Nicholls JI
    Int J Oral Maxillofac Implants; 2011; 26(4):797-806. PubMed ID: 21841990
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Mechanical stability of fully personalized, abutment-free zirconia implant crowns on a novel implant-crown interface.
    Hjerppe J; Jung RE; Hämmerle CH; Özcan M; Mühlemann S
    J Dent; 2022 Jun; 121():104121. PubMed ID: 35395344
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Mechanical stability of angulated zirconia abutments supporting maxillary anterior single crowns on narrow-diameter implants.
    Ma R; Yu P; Zhang Y; Xie C; Tan X; Sun J; Yu H
    Clin Oral Investig; 2023 Jan; 27(1):221-233. PubMed ID: 36161530
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of fatigue loading on the fracture strength and failure mode of lithium disilicate and zirconia implant abutments.
    Elsayed A; Wille S; Al-Akhali M; Kern M
    Clin Oral Implants Res; 2018 Jan; 29(1):20-27. PubMed ID: 28664585
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Fracture Resistance of Titanium, Zirconia, and Ceramic-Reinforced Polyetheretherketone Implant Abutments Supporting CAD/CAM Monolithic Lithium Disilicate Ceramic Crowns After Aging.
    Atsü SS; Aksan ME; Bulut AC
    Int J Oral Maxillofac Implants; 2019; 34(3):622–630. PubMed ID: 30716141
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Resistance to Fracture in Fixed Dental Prostheses Over Cemented and Screw-Retained Implant-Supported Zirconia Cantilevers in the Anterior Region: An In Vitro Study.
    Rues S; Kappel S; Ruckes D; Rammelsberg P; Zenthöfer A
    Int J Oral Maxillofac Implants; 2020; 35(3):521-529. PubMed ID: 32406648
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fracture strength of screw-retained zirconia crowns assembled on zirconia and titanium implants.
    Sadid-Zadeh R; Lin K; Li R; Nagy K
    J Prosthodont; 2024 Mar; 33(3):273-280. PubMed ID: 36973859
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Fracture resistance of crowns cemented on titanium and zirconia implant abutments: a comparison of monolithic versus manually veneered all-ceramic systems.
    Martínez-Rus F; Ferreiroa A; Özcan M; Bartolomé JF; Pradíes G
    Int J Oral Maxillofac Implants; 2012; 27(6):1448-55. PubMed ID: 23189296
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Biomechanical evaluation of anterior implants associated with titanium and zirconia abutments and monotype zirconia implants.
    Brandão de Holanda KA; Armini Caldas R; Amaral M; da Silva Concilio LR; Pino Vitti R
    J Prosthodont Res; 2021 Feb; 65(1):73-77. PubMed ID: 32938877
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Fracture strength of zirconia implant abutments on narrow diameter implants with internal and external implant abutment connections: A study on the titanium resin base concept.
    Sailer I; Asgeirsson AG; Thoma DS; Fehmer V; Aspelund T; Özcan M; Pjetursson BE
    Clin Oral Implants Res; 2018 Apr; 29(4):411-423. PubMed ID: 29527740
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Failure Load of Monolithic Lithium Disilicate Implant-Supported Single Crowns Bonded to Ti-base Abutments versus to Customized Ceramic Abutments after Fatigue.
    Spitznagel FA; Bonfante EA; Vollmer F; Gierthmuehlen PC
    J Prosthodont; 2022 Feb; 31(2):136-146. PubMed ID: 33870577
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of fracture resistance of pressable metal ceramic custom implant abutment with a commercially fabricated CAD/CAM zirconia implant abutment.
    Protopapadaki M; Monaco EA; Kim HI; Davis EL
    J Prosthet Dent; 2013 Nov; 110(5):389-96. PubMed ID: 24011801
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Bending moments of zirconia and titanium implant abutments supporting all-ceramic crowns after aging.
    Mühlemann S; Truninger TC; Stawarczyk B; Hämmerle CH; Sailer I
    Clin Oral Implants Res; 2014 Jan; 25(1):74-81. PubMed ID: 23735182
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Load to failure of different zirconia abutments for an internal hexagon implant.
    Yilmaz B; Salaita LG; Seidt JD; McGlumphy EA; Clelland NL
    J Prosthet Dent; 2015 Sep; 114(3):373-7. PubMed ID: 25976709
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Influence of zirconia abutment preparation on the fracture strength of single implant lithium disilicate crowns after chewing simulation.
    Mitsias M; Koutayas SO; Wolfart S; Kern M
    Clin Oral Implants Res; 2014 Jun; 25(6):675-82. PubMed ID: 23106096
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Fracture resistance of single-tooth implant-supported all-ceramic restorations: an in vitro study.
    Att W; Kurun S; Gerds T; Strub JR
    J Prosthet Dent; 2006 Feb; 95(2):111-6. PubMed ID: 16473084
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.