143 related articles for article (PubMed ID: 33653787)
1. Effect of Biotin on Cardiac Troponin I and High Sensitivity Cardiac Troponin I Assays on Vista 1500 and ADVIA Centaur Analyzer.
Dasgupta A; Khalil S
Ann Clin Lab Sci; 2021 Jan; 51(1):102-105. PubMed ID: 33653787
[TBL] [Abstract][Full Text] [Related]
2. Taking Advantage of Assay Harmonization, Biotin Interference in the LOCI Digoxin Assay Could Be Eliminated by Using the ADVIA Centaur Digoxin Assay.
Dasgupta A; Belousova T; Bourgeois L; Wahed A
Ann Clin Lab Sci; 2018 Sep; 48(5):614-617. PubMed ID: 30373866
[TBL] [Abstract][Full Text] [Related]
3. [Biotin analytical interference on Siemens immunoanalysis on Dimension EXL®: impact on cardiac troponin I and total vitamin D (D
Djebrani M; Jabbour F; Hulot FD; De Mazancourt P
Ann Biol Clin (Paris); 2019 Dec; 77(6):693-696. PubMed ID: 31859648
[TBL] [Abstract][Full Text] [Related]
4. Evaluation of the Siemens ADVIA Centaur high-sensitivity cardiac troponin I assay in serum.
Kavsak PA; Worster A; Hill SA; Jaffe AS
Clin Chim Acta; 2018 Dec; 487():216-221. PubMed ID: 30296440
[TBL] [Abstract][Full Text] [Related]
5. Discrepancy between Cardiac Troponin Assays Due to Endogenous Antibodies.
Lam L; Aspin L; Heron RC; Ha L; Kyle C
Clin Chem; 2020 Mar; 66(3):445-454. PubMed ID: 32031592
[TBL] [Abstract][Full Text] [Related]
6. Independent and combined effects of biotin and hemolysis on high-sensitivity cardiac troponin assays.
Harley K; Bissonnette S; Inzitari R; Schulz K; Apple FS; Kavsak PA; Gunsolus IL
Clin Chem Lab Med; 2021 Jul; 59(8):1431-1443. PubMed ID: 33761581
[TBL] [Abstract][Full Text] [Related]
7. Myocardial Infarction Risk Stratification With a Single Measurement of High-Sensitivity Troponin I.
Sandoval Y; Nowak R; deFilippi CR; Christenson RH; Peacock WF; McCord J; Limkakeng AT; Sexter A; Apple FS
J Am Coll Cardiol; 2019 Jul; 74(3):271-282. PubMed ID: 31319909
[TBL] [Abstract][Full Text] [Related]
8. Sample matrix and high-sensitivity cardiac troponin I assays.
Kavsak PA; Roy C; Malinowski P; Clark L; Lamers S; Bamford K; Hill S; Worster A; Jaffe AS
Clin Chem Lab Med; 2019 Apr; 57(5):745-751. PubMed ID: 30838842
[TBL] [Abstract][Full Text] [Related]
9. Evaluation of 99th percentile and reference change values of the hs-cTnI method using ADVIA Centaur XPT platform: A multicenter study.
Clerico A; Masotti S; Musetti V; Ripoli A; Aloe R; Di Pietro M; Rizzardi S; Dittadi R; Carrozza C; Belloni L; Perrone M; Fasano T; Canovi S; de Santis A; Prontera C; Guiotto C; Cosseddu D; Migliardi M; Bernardini S
Clin Chim Acta; 2019 Aug; 495():161-166. PubMed ID: 30978328
[TBL] [Abstract][Full Text] [Related]
10. Analytical characterization of the Siemens Dimension EXL high-sensitivity cardiac troponin I assay.
Kavsak PA; MacCuish J; Boreyko J; Roy C; Lamers S; Clark L
Clin Biochem; 2019 Jul; 69():52-56. PubMed ID: 31063741
[TBL] [Abstract][Full Text] [Related]
11. Interaction between heparin and cardiac troponin T and troponin I from patients after coronary bypass surgery.
Speth M; Seibold K; Katz N
Clin Biochem; 2002 Jul; 35(5):355-62. PubMed ID: 12270764
[TBL] [Abstract][Full Text] [Related]
12. Biotin interference in TSH, FT4, and FT3 assays based on the LOCI technology: Identifying interference by dilution.
Dasgupta A; Bourgeois L
J Clin Lab Anal; 2019 Feb; 33(2):e22667. PubMed ID: 30221397
[TBL] [Abstract][Full Text] [Related]
13.
Dasgupta A; Khalil S; Paddock T; Wahed A
Ann Clin Lab Sci; 2022 Jan; 52(1):161-163. PubMed ID: 35181630
[TBL] [Abstract][Full Text] [Related]
14. Validation of a commercially available immunoassay for the measurement of bovine cardiac troponin I.
Varga A; Schober KE; Walker WL; Lakritz J; Michael Rings D
J Vet Intern Med; 2009; 23(2):359-65. PubMed ID: 19192157
[TBL] [Abstract][Full Text] [Related]
15. Evaluation of the Atellica TnIH cardiac troponin I assay and assessment of biological equivalence.
Pretorius CJ; Parsonage W; Cullen LW; Wilgen U; De Waal E; Klingberg S; Dimeski G; White R; Greenslade J; Ungerer JPJ
Clin Chem Lab Med; 2022 Jan; 60(2):283-290. PubMed ID: 34800088
[TBL] [Abstract][Full Text] [Related]
16. Biotin at High Concentration Interferes with the LOCI Digoxin Assay but the PETINIA Phenytoin Assay Is Not Affected.
Rodriguez JJ; Acosta F; Bourgeois L; Dasgupta A
Ann Clin Lab Sci; 2018 Mar; 48(2):164-167. PubMed ID: 29678842
[TBL] [Abstract][Full Text] [Related]
17. Analytical evaluation of the new Beckman Coulter Access high sensitivity cardiac troponin I immunoassay.
Lippi G; Ferrari A; Gandini G; Gelati M; Lo Cascio C; Salvagno GL
Clin Chem Lab Med; 2017 Nov; 56(1):157-161. PubMed ID: 28704179
[TBL] [Abstract][Full Text] [Related]
18. Endogenous alkaline phosphatase interference in cardiac troponin I and other sensitive chemiluminescence immunoassays that use alkaline phosphatase activity for signal amplification.
Herman DS; Ranjitkar P; Yamaguchi D; Grenache DG; Greene DN
Clin Biochem; 2016 Oct; 49(15):1118-1121. PubMed ID: 27317886
[TBL] [Abstract][Full Text] [Related]
19. Comparison of Two Commercially Available Immunoassays for the Measurement of Bovine Cardiac Troponin I in Cattle With Induced Myocardial Injury.
Smith JS; Varga A; Schober KE
Front Vet Sci; 2020; 7():531. PubMed ID: 33062647
[No Abstract] [Full Text] [Related]
20. Fully automated ultrasensitive digital immunoassay for cardiac troponin I based on single molecule array technology.
Jarolim P; Patel PP; Conrad MJ; Chang L; Melenovsky V; Wilson DH
Clin Chem; 2015 Oct; 61(10):1283-91. PubMed ID: 26283690
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]