These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
136 related articles for article (PubMed ID: 33662940)
81. Prototype pre-clinical PET scanner with depth-of-interaction measurements using single-layer crystal array and single-ended readout. Lee MS; Kim KY; Ko GB; Lee JS Phys Med Biol; 2017 May; 62(10):3983-3996. PubMed ID: 28406795 [TBL] [Abstract][Full Text] [Related]
82. Wavelength discrimination (WLD) TOF-PET detector with DOI information. Ullah MN; Pratiwi E; Park JH; Lee K; Choi H; Yeom JY Phys Med Biol; 2020 Feb; 65(5):055003. PubMed ID: 31874462 [TBL] [Abstract][Full Text] [Related]
83. Investigation of the limitations of the highly pixilated CdZnTe detector for PET applications. Komarov S; Yin Y; Wu H; Wen J; Krawczynski H; Meng LJ; Tai YC Phys Med Biol; 2012 Nov; 57(22):7355-80. PubMed ID: 23079763 [TBL] [Abstract][Full Text] [Related]
84. A novel method to calibrate DOI function of a PET detector with a dual-ended-scintillator readout. Shao Y; Yao R; Ma T Med Phys; 2008 Dec; 35(12):5829-40. PubMed ID: 19175139 [TBL] [Abstract][Full Text] [Related]
85. Improved spatial resolution in PET scanners using sampling techniques. Surti S; Scheuermann R; Werner ME; Karp JS IEEE Trans Nucl Sci; 2009 Jun; 56(3):596-601. PubMed ID: 19779586 [TBL] [Abstract][Full Text] [Related]
86. Novel preclinical PET geometrical concept using a monolithic scintillator crystal offering concurrent enhancement in spatial resolution and detection sensitivity: a simulation study. Sanaat A; Arabi H; Reza Ay M; Zaidi H Phys Med Biol; 2020 Feb; 65(4):045013. PubMed ID: 31855857 [TBL] [Abstract][Full Text] [Related]
87. A Novel Hybrid NN-ABPE-Based Calibration Method for Improving Accuracy of Lateration Positioning System. Petrović M; Ciężkowski M; Romaniuk S; Wolniakowski A; Miljković Z Sensors (Basel); 2021 Dec; 21(24):. PubMed ID: 34960309 [TBL] [Abstract][Full Text] [Related]
88. A prototype PET scanner with DOI-encoding detectors. Yang Y; Wu Y; Qi J; St James S; Du H; Dokhale PA; Shah KS; Farrell R; Cherry SR J Nucl Med; 2008 Jul; 49(7):1132-40. PubMed ID: 18552140 [TBL] [Abstract][Full Text] [Related]
89. Investigation of spatial resolution improvement by use of a mouth-insert detector in the helmet PET scanner. Ahmed AM; Tashima H; Yamaya T Radiol Phys Technol; 2018 Mar; 11(1):7-12. PubMed ID: 28986818 [TBL] [Abstract][Full Text] [Related]
90. On light sharing TOF-PET modules with depth of interaction and 157 ps FWHM coincidence time resolution. Pizzichemi M; Polesel A; Stringhini G; Gundacker S; Lecoq P; Tavernier S; Paganoni M; Auffray E Phys Med Biol; 2019 Aug; 64(15):155008. PubMed ID: 31239430 [TBL] [Abstract][Full Text] [Related]
91. Robust Timing Calibration for PET Using L1-Norm Minimization. Freese DL; Hsu DFC; Innes D; Levin CS IEEE Trans Med Imaging; 2017 Jul; 36(7):1418-1426. PubMed ID: 28320653 [TBL] [Abstract][Full Text] [Related]
92. Image blurring due to light-sharing in PET block detectors. St James S; Thompson CJ Med Phys; 2006 Feb; 33(2):405-10. PubMed ID: 16532948 [TBL] [Abstract][Full Text] [Related]
93. Evaluation of Compton gamma camera prototype based on pixelated CdTe detectors. Calderón Y; Chmeissani M; Kolstein M; De Lorenzo G J Instrum; 2014 Jun; 9(6):. PubMed ID: 24932209 [TBL] [Abstract][Full Text] [Related]
94. A depth-of-interaction PET detector using a stair-shaped reflector arrangement and a single-ended scintillation light readout. Son JW; Lee MS; Lee JS Phys Med Biol; 2017 Jan; 62(2):465-483. PubMed ID: 28000613 [TBL] [Abstract][Full Text] [Related]
95. A novel single-ended readout depth-of-interaction PET detector fabricated using sub-surface laser engraving. Uchida H; Sakai T; Yamauchi H; Hakamata K; Shimizu K; Yamashita T Phys Med Biol; 2016 Sep; 61(18):6635-6650. PubMed ID: 27541440 [TBL] [Abstract][Full Text] [Related]
96. A high resolution SPECT detector based on thin continuous LYSO. Deprez K; Van Holen R; Vandenberghe S Phys Med Biol; 2014 Jan; 59(1):153-71. PubMed ID: 24334315 [TBL] [Abstract][Full Text] [Related]
97. Study of PET Detector Performance with Varying SiPM Parameters and Readout Schemes. Li X; Lockhart C; Lewellen TK; Miyaoka RS IEEE Trans Nucl Sci; 2011; 58(3):590-596. PubMed ID: 22685348 [TBL] [Abstract][Full Text] [Related]
98. Depth-of-interaction measurement in a single-layer crystal array with a single-ended readout using digital silicon photomultiplier. Lee MS; Lee JS Phys Med Biol; 2015 Aug; 60(16):6495-514. PubMed ID: 26247294 [TBL] [Abstract][Full Text] [Related]
99. Effects of reflector and crystal surface on the performance of a depth-encoding PET detector with dual-ended readout. Ren S; Yang Y; Cherry SR Med Phys; 2014 Jul; 41(7):072503. PubMed ID: 24989406 [TBL] [Abstract][Full Text] [Related]