BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

142 related articles for article (PubMed ID: 33663913)

  • 1. Myocardial motion-corrected phase-sensitive inversion recovery late gadolinium enhancement in free breathing paediatric patients: a comparison with single-shot coherent gradient echo ("TrueFISP") phase-sensitive inversion recovery.
    Xie LJ; Xu R; Xu ZY; Li XS; Zhou XY; Bi XM; Mu JS; Fan HM; Xu HY; Guo YK
    Clin Radiol; 2021 Jun; 76(6):471.e17-471.e25. PubMed ID: 33663913
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Application Value of Motion-correction Phase Sensitive Inversion Recovery (MOCO-PSIR) to Evaluate Myocardial Fibrosis in Patients with Heart Failure Caused by Dilated Cardiomyopathy].
    Cheng W; Wang SM; He S; Wu T; Pan XL; Sun JY; Chen YC; Yu JQ
    Sichuan Da Xue Xue Bao Yi Xue Ban; 2019 Jul; 50(4):483-488. PubMed ID: 31642223
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Motion-corrected free-breathing late gadolinium enhancement combined with a gadolinium contrast agent with a high relaxation rate: an optimized cardiovascular magnetic resonance examination protocol.
    Yan C; Hu J; Li Y; Xie X; Zou Z; Deng Q; Zhou X; Bi X; Zeng M; Liu J
    J Int Med Res; 2020 Oct; 48(10):300060520964664. PubMed ID: 33111603
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Phase-sensitive inversion recovery (PSIR) single-shot TrueFISP for assessment of myocardial infarction at 3 tesla.
    Huber A; Bauner K; Wintersperger BJ; Reeder SB; Stadie F; Mueller E; Schmidt M; Winnik E; Reiser MF; Schoenberg SO
    Invest Radiol; 2006 Feb; 41(2):148-53. PubMed ID: 16428986
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of fast multi-slice and standard segmented techniques for detection of late gadolinium enhancement in ischemic and non-ischemic cardiomyopathy - a prospective clinical cardiovascular magnetic resonance trial.
    Muehlberg F; Arnhold K; Fritschi S; Funk S; Prothmann M; Kermer J; Zange L; von Knobelsdorff-Brenkenhoff F; Schulz-Menger J
    J Cardiovasc Magn Reson; 2018 Feb; 20(1):13. PubMed ID: 29458430
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Myocardial late gadolinium enhancement using delayed 3D IR-FLASH in the pediatric population: feasibility and diagnostic performance compared to single-shot PSIR-bSSFP.
    Saprungruang A; Aguet J; Gill N; Tassos VP; Amirabadi A; Seed M; Yoo SJ; Lam CZ
    J Cardiovasc Magn Reson; 2023 Jan; 25(1):2. PubMed ID: 36683053
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Assessment of late gadolinium enhancement in nonischemic cardiomyopathy: comparison of a fast Phase-Sensitive Inversion Recovery Sequence (PSIR) and a conventional segmented 2D gradient echo recall (GRE) sequence--preliminary findings.
    Elgeti T; Abdel-Aty H; Wagner M; Busjahn A; Schulz-Menger J; Kivelitz D; Dietz R; Hamm B
    Invest Radiol; 2007 Oct; 42(10):671-5. PubMed ID: 17984763
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Free-Breathing Motion-Corrected Single-Shot Phase-Sensitive Inversion Recovery Late-Gadolinium-Enhancement Imaging: A Prospective Study of Image Quality in Patients with Hypertrophic Cardiomyopathy.
    Cha MJ; Cho I; Hong J; Kim SW; Shin SY; Paek MY; Bi X; Kim SM
    Korean J Radiol; 2021 Jul; 22(7):1044-1053. PubMed ID: 33856138
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Bright-blood and dark-blood phase sensitive inversion recovery late gadolinium enhancement and T1 and T2 maps in a single free-breathing scan: an all-in-one approach.
    Kellman P; Xue H; Chow K; Howard J; Chacko L; Cole G; Fontana M
    J Cardiovasc Magn Reson; 2021 Nov; 23(1):126. PubMed ID: 34743718
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Myocardial late gadolinium enhancement: a head-to-head comparison of motion-corrected balanced steady-state free precession with segmented turbo fast low angle shot.
    Fan H; Li S; Lu M; Yin G; Yang X; Lan T; Dai L; Chen X; Li J; Zhang Y; Sirajuddin A; Kellman P; Arai AE; Zhao S
    Clin Radiol; 2018 Jun; 73(6):593.e1-593.e9. PubMed ID: 29548551
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Free-breathing motion-corrected late-gadolinium-enhancement imaging improves image quality in children.
    Olivieri L; Cross R; O'Brien KJ; Xue H; Kellman P; Hansen MS
    Pediatr Radiol; 2016 Jun; 46(7):983-90. PubMed ID: 26886912
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of 3D phase-sensitive inversion-recovery and 2D inversion-recovery MRI at 3.0 T for the assessment of late gadolinium enhancement in patients with hypertrophic cardiomyopathy.
    Morita K; Utsunomiya D; Oda S; Komi M; Namimoto T; Hirai T; Hashida M; Takashio S; Yamamuro M; Yamashita Y
    Acad Radiol; 2013 Jun; 20(6):752-7. PubMed ID: 23473721
    [TBL] [Abstract][Full Text] [Related]  

  • 13. 3D whole-heart grey-blood late gadolinium enhancement cardiovascular magnetic resonance imaging.
    Milotta G; Munoz C; Kunze KP; Neji R; Figliozzi S; Chiribiri A; Hajhosseiny R; Masci PG; Prieto C; Botnar RM
    J Cardiovasc Magn Reson; 2021 May; 23(1):62. PubMed ID: 34024276
    [TBL] [Abstract][Full Text] [Related]  

  • 14. 3D whole-heart phase sensitive inversion recovery CMR for simultaneous black-blood late gadolinium enhancement and bright-blood coronary CMR angiography.
    Ginami G; Neji R; Rashid I; Chiribiri A; Ismail TF; Botnar RM; Prieto C
    J Cardiovasc Magn Reson; 2017 Nov; 19(1):94. PubMed ID: 29178893
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Phase-sensitive inversion recovery single-shot balanced steady-state free precession for detection of myocardial infarction during a single breathhold.
    Huber A; Hayes C; Spannagl B; Rieber J; Klauss V; Schoenberg SO; Reiser M; Wintersperger BJ
    Acad Radiol; 2007 Dec; 14(12):1500-8. PubMed ID: 18035279
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Dark blood late enhancement imaging.
    Kellman P; Xue H; Olivieri LJ; Cross RR; Grant EK; Fontana M; Ugander M; Moon JC; Hansen MS
    J Cardiovasc Magn Reson; 2016 Nov; 18(1):77. PubMed ID: 27817748
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Motion-corrected cardiac MRI is associated with decreased anesthesia exposure in children.
    Christopher AB; Quinn RE; Zoulfagharian S; Matisoff AJ; Cross RR; Xue H; Campbell-Washburn A; Olivieri LJ
    Pediatr Radiol; 2020 Nov; 50(12):1709-1716. PubMed ID: 32696111
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Motion-corrected free-breathing LGE delivers high quality imaging and reduces scan time by half: an independent validation study.
    Captur G; Lobascio I; Ye Y; Culotta V; Boubertakh R; Xue H; Kellman P; Moon JC
    Int J Cardiovasc Imaging; 2019 Oct; 35(10):1893-1901. PubMed ID: 31104178
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Three-dimensional phase-sensitive inversion recovery sequencing in the evaluation of left ventricular myocardial scars in ischemic and non-ischemic cardiomyopathy: comparison to three-dimensional inversion recovery sequencing.
    Kido T; Kido T; Nakamura M; Kawaguchi N; Nishiyama Y; Ogimoto A; Miyagawa M; Mochizuki T
    Eur J Radiol; 2014 Dec; 83(12):2159-2166. PubMed ID: 25311877
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Free-breathing myocardial T2* mapping using GRE-EPI and automatic non-rigid motion correction.
    Jin N; da Silveira JS; Jolly MP; Firmin DN; Mathew G; Lamba N; Subramanian S; Pennell DJ; Raman SV; Simonetti OP
    J Cardiovasc Magn Reson; 2015 Dec; 17():113. PubMed ID: 26699850
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.