These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
258 related articles for article (PubMed ID: 33666016)
1. [Three dimensional finite element analysis of optimal distribution model of fillers in vertebroplasty]. Wang DG; Li Y; Yin HL; Li J; Qu J; Jiang MB; Tian JW Zhongguo Gu Shang; 2021 Jan; 34(1):26-33. PubMed ID: 33666016 [TBL] [Abstract][Full Text] [Related]
2. Three-dimensional finite element analysis of optimal distribution model of vertebroplasty. Wang D; Li Y; Yin H; Li J; Qu J; Jiang M; Tian J Ann Palliat Med; 2020 May; 9(3):1062-1072. PubMed ID: 32434365 [TBL] [Abstract][Full Text] [Related]
3. [Biomechanical effects of different bone cement diffusion patterns after vertebroplasty:finite element analysis]. Yao G; Shen YX; Li M; Cai B Zhongguo Gu Shang; 2021 Aug; 34(8):732-7. PubMed ID: 34423616 [TBL] [Abstract][Full Text] [Related]
4. Biomechanical evaluation of calcium phosphate-based nanocomposite versus polymethylmethacrylate cement for percutaneous kyphoplasty. Lu Q; Liu C; Wang D; Liu H; Yang H; Yang L Spine J; 2019 Nov; 19(11):1871-1884. PubMed ID: 31202837 [TBL] [Abstract][Full Text] [Related]
5. Optimizing bone cement stiffness for vertebroplasty through biomechanical effects analysis based on patient-specific three-dimensional finite element modeling. Peng Y; Du X; Huang L; Li J; Zhan R; Wang W; Xu B; Wu S; Peng C; Chen S Med Biol Eng Comput; 2018 Nov; 56(11):2137-2150. PubMed ID: 29806053 [TBL] [Abstract][Full Text] [Related]
6. Biomechanical effects of bone cement volume on the endplates of augmented vertebral body: a three-dimensional finite element analysis. Yan L; Chang Z; Xu Z; Liu T; He B; Hao D Chin Med J (Engl); 2014; 127(1):79-84. PubMed ID: 24384428 [TBL] [Abstract][Full Text] [Related]
7. Biomechanical study between percutaneous vertebroplasty combined with cement pedicle plasty improves vertebral biomechanical stability: A finite element analysis. Li H; Xiao C; Pan H; Lei Y; Wang H; Li S BMC Musculoskelet Disord; 2024 Jul; 25(1):597. PubMed ID: 39075431 [TBL] [Abstract][Full Text] [Related]
8. Effect of Augmentation Material Stiffness on Adjacent Vertebrae after Osteoporotic Vertebroplasty Using Finite Element Analysis with Different Loading Methods. Cho AR; Cho SB; Lee JH; Kim KH Pain Physician; 2015 Nov; 18(6):E1101-10. PubMed ID: 26606023 [TBL] [Abstract][Full Text] [Related]
9. Spinal loads after osteoporotic vertebral fractures treated by vertebroplasty or kyphoplasty. Rohlmann A; Zander T; Bergmann G Eur Spine J; 2006 Aug; 15(8):1255-64. PubMed ID: 16311752 [TBL] [Abstract][Full Text] [Related]
10. Finite element analysis of vertebroplasty in the osteoporotic T11-L1 vertebral body: Effects of bone cement formulation. Mondal S; MacManus DB; Banche-Niclot F; Vitale-Brovarone C; Fiorilli S; McCarthy HO; Dunne N J Biomed Mater Res B Appl Biomater; 2024 Jan; 112(1):e35359. PubMed ID: 38247244 [TBL] [Abstract][Full Text] [Related]
11. Space between bone cement and bony endplate can trigger higher incidence of augmented vertebral collapse: An in-silico study. Chen J; Lu S; Chen Y; Zhang X; Xi Z; Xie L; Li J J Clin Neurosci; 2024 Jul; 125():152-158. PubMed ID: 38815301 [TBL] [Abstract][Full Text] [Related]
12. Cement injection and postoperative vertebral fractures during vertebroplasty. Hu L; Sun H; Wang H; Cai J; Tao Y; Feng X; Wang Y J Orthop Surg Res; 2019 Jul; 14(1):228. PubMed ID: 31324196 [TBL] [Abstract][Full Text] [Related]
13. Do we have to pursue complete reduction after PVA in osteoporotic vertebral compression fractures: a finite element analysis. Fan Z; Huang H; Lin Y; Zhou J; Lin F; Chen B; Wang H; Su H; Qi J; Huang Y; Huang Y Injury; 2022 Aug; 53(8):2754-2762. PubMed ID: 35760641 [TBL] [Abstract][Full Text] [Related]
14. [Risk factors of non-surgical vertebral fracture after percutaneous kyphoplasty of single segment thoracolumbar fracture]. Wu J; Guan YH; Fan SL Zhongguo Gu Shang; 2017 Sep; 30(9):833-837. PubMed ID: 29455485 [TBL] [Abstract][Full Text] [Related]
15. [Biomechanical effect on adjacent vertebra after percutaneous kyphoplasty with cement leakage into disc: a finite element analysis of thoracolumbar osteoporotic vertebral compression fracture]. Fei Q; Li QJ; Li D; Yang Y; Tang H; Li JJ; Wang BQ; Wang YP Zhonghua Yi Xue Za Zhi; 2011 Jan; 91(1):51-5. PubMed ID: 21418964 [TBL] [Abstract][Full Text] [Related]
16. Finite element analysis of wedge and biconcave deformity in four different height restoration after augmentation of osteoporotic vertebral compression fractures. Zuo XH; Chen YB; Xie P; Zhang WD; Xue XY; Zhang QX; Shan B; Zhang XB; Bao HG; Si YN J Orthop Surg Res; 2021 Feb; 16(1):138. PubMed ID: 33588890 [TBL] [Abstract][Full Text] [Related]
17. Risk of post-vertebroplasty fracture in adjacent vertebral bodies appears correlated with the morphologic extent of bone cement. Sun YC; Teng MM; Yuan WS; Luo CB; Chang FC; Lirng JF; Guo WY; Chang CY J Chin Med Assoc; 2011 Aug; 74(8):357-62. PubMed ID: 21872816 [TBL] [Abstract][Full Text] [Related]
18. Vertebroplasty: only small cement volumes are required to normalize stress distributions on the vertebral bodies. Luo J; Daines L; Charalambous A; Adams MA; Annesley-Williams DJ; Dolan P Spine (Phila Pa 1976); 2009 Dec; 34(26):2865-73. PubMed ID: 20010394 [TBL] [Abstract][Full Text] [Related]
19. Biomechanical effect of vertebroplasty on the adjacent intervertebral levels using a three-dimensional finite element analysis. Lu S; Xu YQ; Zhang MC; Tang X; Wang YL; Zhong SZ Chin J Traumatol; 2007 Apr; 10(2):120-4. PubMed ID: 17371624 [TBL] [Abstract][Full Text] [Related]
20. Effects of vertebroplasty on endplate subsidence in elderly female spines. Nagaraja S; Awada HK; Dreher ML; Bouck JT; Gupta S J Neurosurg Spine; 2015 Mar; 22(3):273-82. PubMed ID: 25525963 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]