BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

156 related articles for article (PubMed ID: 33668075)

  • 21. Dose calculations accounting for breathing motion in stereotactic lung radiotherapy based on 4D-CT and the internal target volume.
    Admiraal MA; Schuring D; Hurkmans CW
    Radiother Oncol; 2008 Jan; 86(1):55-60. PubMed ID: 18082905
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Dosimetric robustness of lung tumor photon radiotherapy evaluated from multiple event CT imaging.
    Olofsson N; Wikström K; Flejmer A; Ahnesjö A; Dasu A
    Phys Med; 2022 Nov; 103():1-10. PubMed ID: 36182764
    [TBL] [Abstract][Full Text] [Related]  

  • 23. The influence of respiratory motion on CT image volume definition.
    Rodríguez-Romero R; Castro-Tejero P
    Med Phys; 2014 Apr; 41(4):041701. PubMed ID: 24694121
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A comparison of internal target volume definition by limited four-dimensional computed tomography, the addition of patient-specific margins, or the addition of generic margins when planning radical radiotherapy for lymph node-positive non-small cell lung cancer.
    Hughes S; McClelland J; Chandler A; Adams M; Boutland J; Withers D; Ahmad S; Blackall J; Tarte S; Hawkes D; Landau D
    Clin Oncol (R Coll Radiol); 2008 May; 20(4):293-300. PubMed ID: 18234482
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Limitations of phase-sorting based pencil beam scanned 4D proton dose calculations under irregular motion.
    Duetschler A; Prendi J; Safai S; Weber DC; Lomax AJ; Zhang Y
    Phys Med Biol; 2022 Dec; 68(1):. PubMed ID: 36571234
    [No Abstract]   [Full Text] [Related]  

  • 26. Real-time 4DMRI-based internal target volume definition for moving lung tumors.
    Rabe M; Thieke C; Düsberg M; Neppl S; Gerum S; Reiner M; Nicolay NH; Schlemmer HP; Debus J; Dinkel J; Landry G; Parodi K; Belka C; Kurz C; Kamp F
    Med Phys; 2020 Apr; 47(4):1431-1442. PubMed ID: 31955430
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Lack of correlation between external fiducial positions and internal tumor positions during breath-hold CT.
    Hunjan S; Starkschall G; Prado K; Dong L; Balter P
    Int J Radiat Oncol Biol Phys; 2010 Apr; 76(5):1586-91. PubMed ID: 20133074
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Variation in target volume and centroid position due to breath holding during four-dimensional computed tomography scanning: A phantom study.
    Miyamae Y; Akimoto M; Sasaki M; Fujimoto T; Yano S; Nakamura M
    J Appl Clin Med Phys; 2020 Jan; 21(1):11-17. PubMed ID: 31385421
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Simulation of dosimetry impact of 4DCT uncertainty in 4D dose calculation for lung SBRT.
    Liu G; Hu F; Ding X; Li X; Shao Q; Wang Y; Yang J; Quan H
    Radiat Oncol; 2019 Jan; 14(1):1. PubMed ID: 30621744
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Planning 4-dimensional computed tomography (4DCT) cannot adequately represent daily intrafractional motion of abdominal tumors.
    Ge J; Santanam L; Noel C; Parikh PJ
    Int J Radiat Oncol Biol Phys; 2013 Mar; 85(4):999-1005. PubMed ID: 23102840
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Deep Learning-Based Internal Target Volume (ITV) Prediction Using Cone-Beam CT Images in Lung Stereotactic Body Radiotherapy.
    Li Z; Zhang S; Zhang L; Li Y; Zheng X; Fu J; Qiu J
    Technol Cancer Res Treat; 2022; 21():15330338211073380. PubMed ID: 35188835
    [No Abstract]   [Full Text] [Related]  

  • 32. Practical approaches to four-dimensional heavy-charged-particle lung therapy.
    Mori S; Wu Z; Folkert MR; Kumagai M; Dobashi S; Sugane T; Baba M
    Radiol Phys Technol; 2010 Jan; 3(1):23-33. PubMed ID: 20821098
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Both four-dimensional computed tomography and four-dimensional cone beam computed tomography under-predict lung target motion during radiotherapy.
    Steiner E; Shieh CC; Caillet V; Booth J; O'Brien R; Briggs A; Hardcastle N; Jayamanne D; Szymura K; Eade T; Keall P
    Radiother Oncol; 2019 Jun; 135():65-73. PubMed ID: 31015172
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Distribution of lung tissue hysteresis during free breathing.
    White B; Zhao T; Lamb J; Wuenschel S; Bradley J; El Naqa I; Low D
    Med Phys; 2013 Apr; 40(4):043501. PubMed ID: 23556925
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Reliability of ITV approach to varying treatment fraction time: a retrospective analysis based on 2D cine MR images.
    Cusumano D; Dhont J; Boldrini L; Chiloiro G; Romano A; Votta C; Longo S; Placidi L; Azario L; De Spirito M; Verellen D; Valentini V
    Radiat Oncol; 2020 Jun; 15(1):152. PubMed ID: 32532334
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A method for selection of beam angles robust to intra-fractional motion in proton therapy of lung cancer.
    Casares-Magaz O; Toftegaard J; Muren LP; Kallehauge JF; Bassler N; Poulsen PR; Petersen JB
    Acta Oncol; 2014 Aug; 53(8):1058-63. PubMed ID: 24975371
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Four-dimensional CT scans for treatment planning in stereotactic radiotherapy for stage I lung cancer.
    Underberg RW; Lagerwaard FJ; Cuijpers JP; Slotman BJ; van Sörnsen de Koste JR; Senan S
    Int J Radiat Oncol Biol Phys; 2004 Nov; 60(4):1283-90. PubMed ID: 15519801
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Use of megavoltage cine-images for studying intra-thoracic motion during radiotherapy for locally advanced lung cancer.
    Muirhead R; van der Weide L; van Sornsen de Koste JR; Cover KS; Senan S
    Radiother Oncol; 2011 May; 99(2):155-60. PubMed ID: 21621867
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Internal target volume determined with expansion margins beyond composite gross tumor volume in three-dimensional conformal radiotherapy for lung cancer.
    Shih HA; Jiang SB; Aljarrah KM; Doppke KP; Choi NC
    Int J Radiat Oncol Biol Phys; 2004 Oct; 60(2):613-22. PubMed ID: 15380599
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Variation in Lung Tumour Breathing Motion between Planning Four-dimensional Computed Tomography and Stereotactic Ablative Radiotherapy Delivery and its Dosimetric Implications: Any Role for Four-dimensional Set-up Verification?
    Ruben JD; Seeley A; Panettieri V; Ackerly T
    Clin Oncol (R Coll Radiol); 2016 Jan; 28(1):21-7. PubMed ID: 26432188
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.