These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 3367104)

  • 1. Protein does not interfere with the ion-selective electrode determination of calcium, sodium or potassium ions.
    Saris NE
    J Clin Chem Clin Biochem; 1988 Feb; 26(2):101-4. PubMed ID: 3367104
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Protein interference with ion-selective electrode measurement depends on reference electrode composition and design.
    Payne RB; Buckley BM; Rawson KM
    Ann Clin Biochem; 1991 Jan; 28 ( Pt 1)():68-72. PubMed ID: 2024938
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Calibration of ion-selective electrodes for use in biological fluids.
    Mohan MS; Bates RG
    Clin Chem; 1975 Jun; 21(7):864-72. PubMed ID: 236844
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effects of ionic strength on ionized calcium measured using reference electrode liquid junctions of varying design and composition.
    Payne RB
    Ann Clin Biochem; 1991 May; 28 ( Pt 3)():235-9. PubMed ID: 1872568
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Activity measurements of calcium, sodium, potassium, and chloride after equilibrium dialysis used to show lack of evidence for protein interference with calcium electrodes.
    Thode J; Boyd JC; Ladenson JH
    Clin Chem; 1987 Oct; 33(10):1811-3. PubMed ID: 3665034
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Cation selective electroanalysis of K(+)-, Na(+)- and Ca2(+) concentrations in acetate dialysis solutions].
    Brixius K; Schindler JG
    Biomed Tech (Berl); 1991; 36(1-2):2-5. PubMed ID: 2031988
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Analytical evaluation of Kone Microlyte determination of ionized magnesium.
    van Ingen HE; Huijgen HJ; Kok WT; Sanders GT
    Clin Chem; 1994 Jan; 40(1):52-5. PubMed ID: 8287544
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Activity and interference effects in measurement of ionized calcium with ion-selective electrodes.
    Grima JM; Brand MJ
    Clin Chem; 1977 Nov; 23(11):2048-54. PubMed ID: 21042
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of hypertonic and isotonic reference electrode junctions for measuring ionized calcium in whole blood: a clinical study.
    Masters PW; Payne RB
    Clin Chem; 1993 Jun; 39(6):1082-5. PubMed ID: 8504542
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The effect of internal sodium and caesium on phasic contraction of patch-clamped rabbit ventricular myocytes.
    Levi AJ; Mitcheson JS; Hancox JC
    J Physiol; 1996 Apr; 492 ( Pt 1)(Pt 1):1-19. PubMed ID: 8730578
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of pH and NaCl on measurements of ionized calcium in matrices of serum and human albumin with a new calcium-selective electrode.
    Rehfeld SJ; Barkeley J; Loken HF
    Clin Chem; 1984 Feb; 30(2):304-7. PubMed ID: 6692542
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of a new semiautomatic electrode system for simultaneous measurement of ionized calcium and pH.
    Thode J; Wandrup J; Aas F; Siggaard-Andersen O
    Scand J Clin Lab Invest; 1982 Sep; 42(5):407-15. PubMed ID: 7156853
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Protein interferes with ionised calcium measurement at the reference electrode liquid junction.
    Payne RB; Jones DP
    Ann Clin Biochem; 1987 Jul; 24 ( Pt 4)():400-7. PubMed ID: 3662389
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Ion effects in measurement of ionized calcium with a calcium-selective electrode.
    Kaufman RA; Tietz NW
    Clin Chem; 1980 Apr; 26(5):640-4. PubMed ID: 6266696
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ion-selective electrode for measuring low Ca2+ concentrations in the presence of high K+, Na+ and Mg2+ background.
    Bedlechowicz-Sliwakowska I; Lingenfelter P; Sokalski T; Lewenstam A; Maj-Zurawska M
    Anal Bioanal Chem; 2006 Aug; 385(8):1477-82. PubMed ID: 16847621
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Determination of electrolytes in serum and plasma].
    Külpmann WR
    Wien Klin Wochenschr Suppl; 1992; 192():37-41. PubMed ID: 1502823
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Reliability of the Hitachi sodium and potassium electrodes assessed.
    Winkel P; Wilken M; Christiansen J; Buch B
    Clin Chem; 1985 Mar; 31(3):457-9. PubMed ID: 3971568
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Ionic binding, net charge, and Donnan effect of human serum albumin as a function of pH.
    Fogh-Andersen N; Bjerrum PJ; Siggaard-Andersen O
    Clin Chem; 1993 Jan; 39(1):48-52. PubMed ID: 8419057
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Sweat Sodium, Potassium, and Chloride Concentrations Analyzed Same Day as Collection Versus After 7 Days Storage in a Range of Temperatures.
    Baker LB; Barnes KA; Sopeña BC; Nuccio RP; Reimel AJ; Ungaro CT
    Int J Sport Nutr Exerc Metab; 2018 May; 28(3):238-245. PubMed ID: 29140143
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Binding strength of calcium ion to bovine alpha-lactalbumin.
    Hamano M; Nitta K; Kuwajima K; Sugai S
    J Biochem; 1986 Dec; 100(6):1617-22. PubMed ID: 3571190
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.