These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

139 related articles for article (PubMed ID: 33673259)

  • 1. Towards Non-Invasive Diagnosis of Skin Cancer: Sensing Depth Investigation of Open-Ended Coaxial Probes.
    Aydinalp C; Joof S; Yilmaz T
    Sensors (Basel); 2021 Feb; 21(4):. PubMed ID: 33673259
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Towards Accurate Microwave Characterization of Tissues: Sensing Depth Analysis of Open-Ended Coaxial Probes with Ex Vivo Rat Breast and Skin Tissues.
    Aydinalp C; Joof S; Yilmaz T
    Diagnostics (Basel); 2021 Feb; 11(2):. PubMed ID: 33670666
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Sensing volume of tissue dielectric property measurement with open-ended coaxial probe].
    Liu Y; Huang Y; Xin X; Yu X
    Nan Fang Yi Ke Da Xue Xue Bao; 2020 Jul; 40(7):1036-1043. PubMed ID: 32895168
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Characterization of Open-Ended Coaxial Probe Sensing Depth with Respect to Aperture Size for Dielectric Property Measurement of Heterogeneous Tissues.
    Aydinalp C; Joof S; Dilman I; Akduman I; Yilmaz T
    Sensors (Basel); 2022 Jan; 22(3):. PubMed ID: 35161506
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Machine learning aided diagnosis of hepatic malignancies through in vivo dielectric measurements with microwaves.
    Yilmaz T; Kılıç MA; Erdoğan M; Çayören M; Tunaoğlu D; Kurtoğlu İ; Yaslan Y; Çayören H; Arkan AE; Teksöz S; Cancan G; Kepil N; Erdamar S; Özcan M; Akduman İ; Kalkan T
    Phys Med Biol; 2016 Jul; 61(13):5089-5102. PubMed ID: 27321132
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Open-Ended Coaxial Dielectric Probe Effective Penetration Depth Determination.
    Meaney PM; Gregory AP; Seppälä J; Lahtinen T
    IEEE Trans Microw Theory Tech; 2016 Mar; 64(3):915-923. PubMed ID: 27346890
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An Analysis of Open-Ended Coaxial Probe Sensitivity to Heterogeneous Media.
    Brace CL; Etoz S
    Sensors (Basel); 2020 Sep; 20(18):. PubMed ID: 32961742
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Penetration of electromagnetic fields of an open-ended coaxial probe between 1 MHz and 1 GHz in dielectric skin measurements.
    Alanen E; Lahtinen T; Nuutinen J
    Phys Med Biol; 1999 Jul; 44(7):N169-76. PubMed ID: 10442720
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Sensitivity investigation of open-ended coaxial probe in skin cancer detection.
    Xu G; Liu H; Huang Q; Yu X; Nan X; Han J
    Phys Eng Sci Med; 2023 Jun; 46(2):609-621. PubMed ID: 36913123
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Microwave open-ended coaxial dielectric probe: interpretation of the sensing volume re-visited.
    Meaney PM; Gregory AP; Epstein NR; Paulsen KD
    BMC Med Phys; 2014; 14():3. PubMed ID: 25002909
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Open-Ended Coaxial Probe Technique for Dielectric Measurement of Biological Tissues: Challenges and Common Practices.
    La Gioia A; Porter E; Merunka I; Shahzad A; Salahuddin S; Jones M; O'Halloran M
    Diagnostics (Basel); 2018 Jun; 8(2):. PubMed ID: 29874833
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Study on the effective measurement area of an open-ended coaxial probe for the dielectric measurement of biological tissues.
    Zhang L; Liu B; Ji Z
    Technol Health Care; 2023; 31(2):621-633. PubMed ID: 36314231
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Comparison of dielectric properties of normal human esophagus and esophageal cancer using an open-ended coaxial probe].
    Huang Q; Lu D; Han J; Yu H; Dong W; Cai K; Yu X
    Nan Fang Yi Ke Da Xue Xue Bao; 2021 Nov; 41(11):1741-1746. PubMed ID: 34916203
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Study on the difference of high frequency dielectric properties of biological tissues measured by air and packed coaxial probe].
    Qin Y; Yang L; Fu F; Dai M; Zhang L
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2023 Oct; 40(5):886-893. PubMed ID: 37879917
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A Transmission-Based Dielectric Property Probe for Clinical Applications.
    Meaney P; Rydholm T; Brisby H
    Sensors (Basel); 2018 Oct; 18(10):. PubMed ID: 30332809
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of Open-Ended Coaxial Probe-to-Tissue Contact Pressure on Dielectric Measurements.
    Maenhout G; Markovic T; Ocket I; Nauwelaers B
    Sensors (Basel); 2020 Apr; 20(7):. PubMed ID: 32268598
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Analysis of dielectric properties of metastatic and non-metastatic lymph nodes from lung cancer surgeries using an open-ended coaxial probe].
    Sun Y; Yu H; Zhou D; Xin X; Lu D; Cai K; Yu X
    Nan Fang Yi Ke Da Xue Xue Bao; 2019 Nov; 39(11):1364-1369. PubMed ID: 31852649
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Improved circuit model of open-ended coaxial probe for measurement of the biological tissue dielectric properties between megahertz and gigahertz.
    Zhang L; Shi X; You F; Liu P; Dong X
    Physiol Meas; 2013 Oct; 34(10):N83-96. PubMed ID: 24021242
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Multiclass Classification of Hepatic Anomalies with Dielectric Properties: From Phantom Materials to Rat Hepatic Tissues.
    Yilmaz T
    Sensors (Basel); 2020 Jan; 20(2):. PubMed ID: 31963628
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Broadband Dielectric Spectroscopy with a Microwave Ablation Antenna.
    Vidjak K; Hessinger C; Cavagnaro M
    Sensors (Basel); 2023 Feb; 23(5):. PubMed ID: 36904783
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.