These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

140 related articles for article (PubMed ID: 33673972)

  • 1. Editorial Commentary: Efforts to Heal Meniscal Radial Tears Are Ongoing.
    Kim JG; Lee DW
    Arthroscopy; 2021 Mar; 37(3):941-943. PubMed ID: 33673972
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Biomechanical Comparison of 3 Novel Repair Techniques for Radial Tears of the Medial Meniscus: The 2-Tunnel Transtibial Technique, a "Hybrid" Horizontal and Vertical Mattress Suture Configuration, and a Combined "Hybrid Tunnel" Technique.
    Buckley PS; Kemler BR; Robbins CM; Aman ZS; Storaci HW; Dornan GJ; LaPrade RF
    Am J Sports Med; 2019 Mar; 47(3):651-658. PubMed ID: 30624953
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Biomechanical Comparison of Vertical Mattress and Cross-stitch Suture Techniques and Single- and Double-Row Configurations for the Treatment of Bucket-Handle Medial Meniscal Tears.
    Nakama GY; Kaleka CC; Franciozi CE; Astur DC; Debieux P; Krob JJ; Aman ZS; Kemler BR; Storaci HW; Dornan GJ; Cohen M; LaPrade RF
    Am J Sports Med; 2019 Apr; 47(5):1194-1202. PubMed ID: 30897004
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Several Techniques Exist With Favorable Biomechanical Outcomes in Radial Meniscus Tear Repair-A Systematic Review.
    Oosten J; Yoder R; DiBartola A; Bowler J; Sparks A; Duerr R; Magnussen R; Kaeding C; Flanigan D
    Arthroscopy; 2022 Aug; 38(8):2557-2578.e4. PubMed ID: 35189305
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Tibiofemoral Contact Mechanics After Horizontal or Ripstop Suture in Inside-Out and Transtibial Repair for Meniscus Radial Tears in a Porcine Model.
    Zhang HZ; Zhou YF; Li WP; Luo H; Wu JT; Jiang C; Chen Z; Hou JY; Yang R; Song B; Zhang ZZ
    Arthroscopy; 2021 Mar; 37(3):932-940.e2. PubMed ID: 33227321
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Biomechanical Comparison of Suture Techniques in Radial Meniscal Tears Using Gap Configuration Analysis.
    Lee SS; Lee MC; Lee JH; Kim TW
    Orthopedics; 2019 Sep; 42(5):e443-e448. PubMed ID: 31408521
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Strategies for repair of radial tears close to the meniscal rim--biomechanical analysis with a cyclic loading protocol.
    Herbort M; Siam S; Lenschow S; Petersen W; Zantop T
    Am J Sports Med; 2010 Nov; 38(11):2281-7. PubMed ID: 20889985
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A Novel Repair Method for Radial Tears of the Medial Meniscus: Biomechanical Comparison of Transtibial 2-Tunnel and Double Horizontal Mattress Suture Techniques Under Cyclic Loading.
    Bhatia S; Civitarese DM; Turnbull TL; LaPrade CM; Nitri M; Wijdicks CA; LaPrade RF
    Am J Sports Med; 2016 Mar; 44(3):639-45. PubMed ID: 26646516
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Editorial Commentary: All-Inside Double-Vertical Cross-Suture is an Effective Technique for Knee Meniscus Radial Tear Repair, but There is No Gold-Standard Evaluation Tool for Evaluating Healing and Function of the Repaired Meniscus.
    Hamada M; Tsujii A
    Arthroscopy; 2022 Jun; 38(6):1930-1932. PubMed ID: 35660186
    [TBL] [Abstract][Full Text] [Related]  

  • 10. New suture method for radial tears of the meniscus: biomechanical analysis of cross-suture and double horizontal suture techniques using cyclic load testing.
    Matsubara H; Okazaki K; Izawa T; Tashiro Y; Matsuda S; Nishimura T; Nakanishi Y; Kawamura H; Iwamoto Y
    Am J Sports Med; 2012 Feb; 40(2):414-8. PubMed ID: 22016457
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Meniscal repair using the inside-out technique with cross stitch.
    Cruz-López F; Trueba C; Almazán A; Sierra L; Francisco P; Villalobos-Cordova E; Ibarra C
    Sports Med Arthrosc Rev; 2012 Jun; 20(2):101-5. PubMed ID: 22555207
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Editorial Commentary: A Stitch in Time May Save the Meniscus…but Not the Articular Cartilage?
    Kurzweil PR
    Arthroscopy; 2019 May; 35(5):1517-1519. PubMed ID: 30803869
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Biomechanical comparison of arthroscopic repair constructs for radial tears of the meniscus.
    Branch EA; Milchteim C; Aspey BS; Liu W; Saliman JD; Anz AW
    Am J Sports Med; 2015 Sep; 43(9):2270-6. PubMed ID: 26245325
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparable Outcomes After Bucket-Handle Meniscal Repair and Vertical Meniscal Repair Can Be Achieved at a Minimum 2 Years' Follow-up.
    Moatshe G; Cinque ME; Godin JA; Vap AR; Chahla J; LaPrade RF
    Am J Sports Med; 2017 Nov; 45(13):3104-3110. PubMed ID: 28806092
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Meniscal repair: Technique.
    Beaufils P; Pujol N
    Orthop Traumatol Surg Res; 2018 Feb; 104(1S):S137-S145. PubMed ID: 29175557
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Arthroscopic meniscal repair with use of the outside-in technique.
    Rodeo SA
    Instr Course Lect; 2000; 49():195-206. PubMed ID: 10829175
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Biomechanical evaluation of meniscal repair systems: a comparison of the Meniscal Viper Repair System, the vertical mattress FasT-Fix Device, and vertical mattress ethibond sutures.
    Chang HC; Nyland J; Caborn DN; Burden R
    Am J Sports Med; 2005 Dec; 33(12):1846-52. PubMed ID: 16157854
    [TBL] [Abstract][Full Text] [Related]  

  • 18. "Horizontal butterfly" technique in repair of radial meniscus tears: A biomechanical study.
    Aşçi M; Balta O; Kurnaz R; Eren MB; Kuyucu YE; Güneş T
    Acta Orthop Traumatol Turc; 2018 Sep; 52(5):392-396. PubMed ID: 30120005
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A novel bioabsorbable conduit augments healing of avascular meniscal tears in a dog model.
    Cook JL; Fox DB
    Am J Sports Med; 2007 Nov; 35(11):1877-87. PubMed ID: 17702993
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The concept of three-dimensional hold of both circumferential and radial collagen fibres of the meniscus.
    Abdelkafy A
    Knee Surg Sports Traumatol Arthrosc; 2015 Jan; 23(1):20-5. PubMed ID: 23404512
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.