BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

155 related articles for article (PubMed ID: 33691356)

  • 1. Measurement of Fractional Exhaled Nitric Oxide in Adults: Comparison of Two Different Analyzers (NIOX VERO and NObreath).
    Kang SY; Lee SM; Lee SP
    Tuberc Respir Dis (Seoul); 2021 Jul; 84(3):182-187. PubMed ID: 33691356
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Measurement of exhaled nitric oxide concentration in asthma: a systematic review and economic evaluation of NIOX MINO, NIOX VERO and NObreath.
    Harnan SE; Tappenden P; Essat M; Gomersall T; Minton J; Wong R; Pavord I; Everard M; Lawson R
    Health Technol Assess; 2015 Oct; 19(82):1-330. PubMed ID: 26484874
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of fractional exhaled nitric oxide levels measured by different analyzers produced by different manufacturers.
    Saito J; Kikuchi M; Fukuhara A; Sato S; Rikimaru M; Suzuki Y; Uematsu M; Fukuhara N; Kawamata T; Umeda T; Togawa R; Sato Y; Koizumi T; Hirai K; Minemura H; Nikaido T; Kanazawa K; Tanino Y; Shibata Y; Munakata M
    J Asthma; 2020 Nov; 57(11):1216-1226. PubMed ID: 31288573
    [No Abstract]   [Full Text] [Related]  

  • 4. Measurement of Exhaled Nitric Oxide in Children: A Comparison Between NObreath® and NIOX VERO® Analyzers.
    Inoue Y; Sato S; Manabe T; Makita E; Chiyotanda M; Takahashi K; Yamamoto H; Yanagida N; Ebisawa M
    Allergy Asthma Immunol Res; 2018 Sep; 10(5):478-489. PubMed ID: 30088368
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Difference between two exhaled nitric oxide analyzers, NIOX VERO
    Tanabe Y; Harada N; Ito J; Matsuno K; Takeshige T; Harada S; Takemasa M; Kotajima M; Ishimori A; Katsura Y; Makino F; Atsuta R; Takahashi K
    J Asthma; 2019 Feb; 56(2):167-172. PubMed ID: 30335533
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [DIFFERENCES IN FRACTION OF EXHALED NITRIC OXIDE VALUES MEASURED BY TWO HAND-HELDED ANALYZERS (NObreath
    Tsuburai T; Kamide Y; Nakamura Y; Tomita Y; Hamada Y; Watai K; Hayashi H; Sekiya K; Mitsui C; Fukutomi Y; Mori A; Taniguchi M
    Arerugi; 2017; 66(3):204-208. PubMed ID: 28515402
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of three different exhaled nitric oxide analyzers in chronic respiratory disorders.
    Molino A; Fuschillo S; Mosella M; Accardo M; Guida P; Motta A; Maniscalco M
    J Breath Res; 2019 Mar; 13(2):021002. PubMed ID: 30673653
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The comparison of two exhaled nitric oxide analyzers: NIOX VERO and SUNVOU-CA2122.
    Lei W; Li F; Tang XM; Bian S; Wang JJ; Huang JA
    J Breath Res; 2021 Jan; 15(2):. PubMed ID: 33291088
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Fractional exhaled nitric oxide: comparison between portable devices and correlation with sputum eosinophils.
    Yune S; Lee JY; Choi DC; Lee BJ
    Allergy Asthma Immunol Res; 2015 Jul; 7(4):404-8. PubMed ID: 25749783
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Measurement of fractional exhaled nitric oxide by a new portable device: comparison with the standard technique.
    Pisi R; Aiello M; Tzani P; Marangio E; Olivieri D; Chetta A
    J Asthma; 2010 Sep; 47(7):805-9. PubMed ID: 20670207
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fractional exhaled nitric oxide measurement: Comparison between the Sunvou-CA2122 analyzer and the NIOX VERO analyzer.
    Huang T; Liu B; Yang D; Liu C
    J Asthma; 2021 Jan; 58(1):52-59. PubMed ID: 31512532
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A comparative study of the RuiBreath and NIOX VERO analyzers for detecting fractional exhaled nitric oxide.
    Liu Y; Chang X; Liang L; Hou Z; Lu Y
    J Thorac Dis; 2021 Jul; 13(7):4418-4426. PubMed ID: 34422368
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Agreement between two devices for measuring exhaled nitric oxide].
    Sardón Prado O; Aldasoro Ruiz A; Korta Murua J; Mintegui Aramburu J; Emparanza Knorr JI; Pérez-Yarza EG
    An Pediatr (Barc); 2007 Dec; 67(6):572-7. PubMed ID: 18053523
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of two exhaled nitric oxide analyzers: the NIOX MINO hand-held electrochemical analyzer and the NOA280i stationary chemiluminescence analyzer.
    Kim SH; Moon JY; Kwak HJ; Kim SI; Park DW; Kim JW; Kim TH; Sohn JW; Shin DH; Park SS; Yoon HJ
    Respirology; 2012 Jul; 17(5):830-4. PubMed ID: 22404295
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Reliability of a new hand-held device for the measurement of exhaled nitric oxide.
    Khalili B; Boggs PB; Bahna SL
    Allergy; 2007 Oct; 62(10):1171-4. PubMed ID: 17845587
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Differences of fractional exhaled nitric oxide (FeNO) levels performed using two different analyzers].
    Saito J; Fukuhara A; Sato Y; Sato S; Saito K; Nakagawa N; Inokoshi Y; Ishii T; Tanino Y; Ishida T; Munakata M
    Nihon Kokyuki Gakkai Zasshi; 2010 Jan; 48(1):17-22. PubMed ID: 20163016
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Validation of a new portable system containing both FeNO analysis and spirometry measurement.
    Li Y; Huang K; Li W; Peng Y; Tang X; Yang T
    Front Med (Lausanne); 2023; 10():1210329. PubMed ID: 37720515
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Variability of FeNO in healthy subjects at 2240 meters above sea level.
    Gochicoa-Rangel L; Rojas-Cisneros F; Miguel-Reyes JL; Guerrero-Zúñiga S; Mora-Romero U; Maldonado-Mortera AK; Torre-Bouscoulet L
    J Clin Monit Comput; 2016 Aug; 30(4):445-9. PubMed ID: 26174797
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Can we use portable nitric oxide analyzer in young children?
    Kalliola S; Malmberg P; Rito T; Pelkonen AS; Mäkelä MJ
    Pediatr Pulmonol; 2011 Jul; 46(7):627-31. PubMed ID: 21634029
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of exhalation time methods (6 sec vs. 10 sec) of a hand-held exhaled nitric oxide analyzer.
    Ito Y; Adachi Y; Itazawa T; Okabe Y; Adachi YS; Katsumuma T; Miyawaki T
    Pediatr Pulmonol; 2010 Oct; 45(10):1005-8. PubMed ID: 20648669
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.