These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

784 related articles for article (PubMed ID: 33703860)

  • 1. Cardiovascular thrombotic complications in acute ischemic stroke assessed by chest spectral computed tomography during COVID-19.
    Rodriguez-Granillo GA; Cirio JJ; Ciardi C; Caballero ML; Diluca P; Castrillon R; Ceron M; Scrivano E; Lylyk P
    Minerva Cardiol Angiol; 2021 Oct; 69(5):606-618. PubMed ID: 33703860
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Early Triage of Cardioembolic Sources Using Chest Spectral Computed Tomography in Acute Ischemic Stroke.
    Rodríguez-Granillo GA; Cirio JJ; Ciardi C; Caballero ML; Ceron M; Bleise C; Diluca P; Lylyk P
    J Stroke Cerebrovasc Dis; 2021 Jun; 30(6):105731. PubMed ID: 33751990
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Hyperacute Incidental Late Myocardial Enhancement in Ischemic Stroke Using Chest Spectral CT: Relationship with Etiology.
    Rodriguez-Granillo GA; Cirio JJ; Ciardi C; Caballero ML; Fontana LA; Buezas MD; Diluca P; Lylyk P
    Rev Cardiovasc Med; 2022 Mar; 23(3):93. PubMed ID: 35345260
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Improved Opacification of a Suboptimally Enhanced Pulmonary Artery in Chest CT: Experience Using a Dual-Layer Detector Spectral CT.
    Bae K; Jeon KN; Cho SB; Park SE; Moon JI; Baek HJ; Choi BH
    AJR Am J Roentgenol; 2018 Apr; 210(4):734-741. PubMed ID: 29446668
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Spectral cardiac CT in acute stroke patients.
    Larsen N; Austein F; Klintz T; Campbell G; Sedaghat S; Aludin S; Schunk D; Both M; Jansen O; Langguth P
    Sci Rep; 2023 Apr; 13(1):6781. PubMed ID: 37185943
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy of Calcium Scoring calculated from contrast-enhanced Coronary Computed Tomography Angiography using a dual-layer spectral CT: A comparison of Calcium Scoring from real and virtual non-contrast data.
    Nadjiri J; Kaissis G; Meurer F; Weis F; Laugwitz KL; Straeter AS; Muenzel D; Noël PB; Rummeny EJ; Rasper M
    PLoS One; 2018; 13(12):e0208588. PubMed ID: 30521612
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of Virtual Monoenergetic Images on Pulmonary Vasculature Using the Dual-Layer Detector-Based Spectral Computed Tomography.
    Ghandour A; Sher A; Rassouli N; Dhanantwari A; Rajiah P
    J Comput Assist Tomogr; 2018; 42(6):858-865. PubMed ID: 29659426
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Virtual Monoenergetic Images from Spectral Detector CT Enable Radiation Dose Reduction in Unenhanced Cranial CT.
    Reimer RP; Flatten D; Lichtenstein T; Zopfs D; Neuhaus V; Kabbasch C; Maintz D; Borggrefe J; Große Hokamp N
    AJNR Am J Neuroradiol; 2019 Oct; 40(10):1617-1623. PubMed ID: 31537517
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Image quality characteristics for virtual monoenergetic images using dual-layer spectral detector CT: Comparison with conventional tube-voltage images.
    Sakabe D; Funama Y; Taguchi K; Nakaura T; Utsunomiya D; Oda S; Kidoh M; Nagayama Y; Yamashita Y
    Phys Med; 2018 May; 49():5-10. PubMed ID: 29866343
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Initial Clinical Experience of Virtual Monoenergetic Imaging Improves Stent Visualization in Lower Extremity Run-Off CT Angiography by Dual-Layer Spectral Detector CT.
    Zhang D; Xie Y; Wang Y; Guo N; Wang Y; Jin Z; Xue H
    Acad Radiol; 2020 Jun; 27(6):825-832. PubMed ID: 31623997
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Technical Note: Quantitative accuracy evaluation for spectral images from a detector-based spectral CT scanner using an iodine phantom.
    Duan X; Arbique G; Guild J; Xi Y; Anderson J
    Med Phys; 2018 May; 45(5):2048-2053. PubMed ID: 29479712
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Initial experience with dual-layer detector spectral CT for diagnosis of blood or contrast after endovascular treatment for ischemic stroke.
    Bernsen MLE; Veendrick PB; Martens JM; Pijl MEJ; Hofmeijer J; van Gorp MJ
    Neuroradiology; 2022 Jan; 64(1):69-76. PubMed ID: 34046731
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Dual-layer spectral detector CT monoenergetic reconstruction improves image quality of non-contrast cerebral CT as compared with conventional single energy CT.
    Zhao XM; Wang M; Wu RZ; Dharaiya E; Feng F; Li ML; You H; Wang Y; Wang YN; Jin ZY
    Eur J Radiol; 2018 Jun; 103():131-138. PubMed ID: 29803379
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Image quality of conventional images of dual-layer SPECTRAL CT: A phantom study.
    van Ommen F; Bennink E; Vlassenbroek A; Dankbaar JW; Schilham AMR; Viergever MA; de Jong HWAM
    Med Phys; 2018 Jul; 45(7):3031-3042. PubMed ID: 29749624
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Assessment of an advanced image-based technique to calculate virtual monoenergetic computed tomographic images from a dual-energy examination to improve contrast-to-noise ratio in examinations using iodinated contrast media.
    Grant KL; Flohr TG; Krauss B; Sedlmair M; Thomas C; Schmidt B
    Invest Radiol; 2014 Sep; 49(9):586-92. PubMed ID: 24710203
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Effect of Monochromatic Energy Image Synthesized from Dual-layer Detector Spectral CT on Imaging of Inferior Vena Cava].
    Zou Y; Wang S; Li T; Chen K; Zhang X; Luo C; Yang L
    Zhongguo Yi Xue Ke Xue Yuan Xue Bao; 2020 Jun; 42(3):359-363. PubMed ID: 32616132
    [No Abstract]   [Full Text] [Related]  

  • 17. Novel flat-panel cone-beam CT compared to multi-detector CT for assessment of acute ischemic stroke: A prospective study.
    Nicholson P; Cancelliere NM; Bracken J; Hummel E; van Nijnatten F; Withagen P; van de Haar P; Hallacoglu B; van Vlimmeren M; Agid R; Krings T; Mendes Pereira V
    Eur J Radiol; 2021 May; 138():109645. PubMed ID: 33725654
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Venous-phase chest CT with reduced contrast medium dose: Utilization of spectral low keV monoenergetic images improves image quality.
    Hickethier T; Kroeger JR; Lennartz S; Doerner J; Maintz D; Chang DH
    Eur J Radiol; 2020 Jan; 122():108756. PubMed ID: 31786505
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Potential of dual-layer spectral CT for the differentiation between hemorrhage and iodinated contrast medium in the brain after endovascular treatment of ischemic stroke patients.
    Riederer I; Fingerle AA; Zimmer C; Noël PB; Makowski MR; Pfeiffer D
    Clin Imaging; 2021 Nov; 79():158-164. PubMed ID: 33962188
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Arterial Phase CTA Replacement by a Virtual Arterial Phase Reconstruction from a Venous Phase CTA: Preliminary Results Using Detector-Based Spectral CT.
    Patel AA; Sutphin PD; Xi Y; Abbara S; Kalva SP
    Cardiovasc Intervent Radiol; 2019 Feb; 42(2):250-259. PubMed ID: 30357464
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 40.