These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

130 related articles for article (PubMed ID: 3370801)

  • 1. Development and evaluation of an automated dye-binding assay for protein in cerebrospinal fluid.
    Huang CM
    Clin Chem; 1988 May; 34(5):980-3. PubMed ID: 3370801
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Protein concentration of cerebrospinal fluid by precipitation with Pyrogallol Red prior to sodium dodecyl sulphate-polyacrylamide gel electrophoresis.
    Williams KM; Marshall T
    J Biochem Biophys Methods; 2001 Feb; 47(3):197-207. PubMed ID: 11245891
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Automated determination of urine and cerebrospinal fluid proteins with Coomassie Brilliant Blue and the Abbott ABA-100.
    Heick HM; Bégin-Heick N; Acharya C; Mohammed A
    Clin Biochem; 1980 Apr; 13(2):81-3. PubMed ID: 7389075
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An improvement of the Coomassie Blue dye binding method allowing an equal sensitivity to various proteins: application to cerebrospinal fluid.
    Macart M; Gerbaut L
    Clin Chim Acta; 1982 Jun; 122(1):93-101. PubMed ID: 7094350
    [No Abstract]   [Full Text] [Related]  

  • 5. Application of a silver-binding assay to the determination of protein in cerebrospinal fluid.
    Krystal G; Lam V; Schreiber WE
    Clin Chem; 1989 May; 35(5):860-4. PubMed ID: 2470537
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A continuous-flow technique with Coomassie Brilliant Blue for cerebrospinal fluid protein assay.
    Gillery P; Locre F; Malgras A; Borel JP
    Clin Chem; 1985 Jun; 31(6):1092-3. PubMed ID: 3995750
    [No Abstract]   [Full Text] [Related]  

  • 7. Improved dye-binding procedure--once again, or once too much?
    Macart M; Gerbaut L
    Clin Chem; 1985 Apr; 31(4):651-2. PubMed ID: 3978808
    [No Abstract]   [Full Text] [Related]  

  • 8. Standardization of the Coomassie Blue method for cerebrospinal fluid proteins.
    Johnson JA; Lott HA
    Clin Chem; 1978 Nov; 24(11):1931-3. PubMed ID: 709824
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Total protein measurement in canine cerebrospinal fluid: agreement between a turbidimetric assay and 2 dye-binding methods and determination of reference intervals using an indirect a posteriori method.
    Riond B; Steffen F; Schmied O; Hofmann-Lehmann R; Lutz H
    Vet Clin Pathol; 2014 Mar; 43(1):78-88. PubMed ID: 24471791
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effects of sodium dodecylsulphate, dye concentration and paraprotein on coomassie blue dye-binding assays for protein in urine.
    Lim CW; Chisnall WN; Stokes YM; Pratt R; Crooke MJ
    Clin Biochem; 1988 Oct; 21(5):277-81. PubMed ID: 3233737
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Interference in the Coomassie Brilliant Blue and Pyrogallol Red protein dye-binding assays is increased by the addition of sodium dodecyl sulfate to the dye reagents.
    Marshall T; Williams KM
    Anal Biochem; 2004 Aug; 331(2):255-9. PubMed ID: 15265730
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Is standardization more important than methodology for assay of total protein in cerebrospinal fluid?
    Gerbaut L; Macart M
    Clin Chem; 1986 Feb; 32(2):353-5. PubMed ID: 3943199
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Improved dye-binding procedure for determining microgram quantities of protein in cerebrospinal fluid--once again.
    Stahl M
    Clin Chem; 1984 Nov; 30(11):1878. PubMed ID: 6488535
    [No Abstract]   [Full Text] [Related]  

  • 14. Automated calmagite compleximetric measurement of magnesium in serum, with sequential addition of EDTA to eliminate endogenous interference.
    Liedtke RJ; Kroon G
    Clin Chem; 1984 Nov; 30(11):1801-4. PubMed ID: 6435911
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Centrifugal analysis with automated sequential reagent addition: measurement of serum calcium.
    Liedtke RJ; Kroon G; Batjer JD
    Clin Chem; 1981 Dec; 27(12):2025-8. PubMed ID: 6796291
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Background-free, fast protein staining in sodium dodecyl sulfate polyacrylamide gel using counterion dyes, zincon and ethyl violet.
    Choi JK; Tak KH; Jin LT; Hwang SY; Kwon TI; Yoo GS
    Electrophoresis; 2002 Dec; 23(24):4053-9. PubMed ID: 12481259
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Automated nephelometry of total protein in cerebrospinal fluid.
    Sindic CJ; Cambiaso CL
    Clin Chem; 1982 Jul; 28(7):1707-8. PubMed ID: 7083569
    [No Abstract]   [Full Text] [Related]  

  • 18. [The Coomassie Brilliant Blue method of protein quantitation. (1) Basic examination of the method and cerebrospinal fluid protein quantitation (author's transl)].
    Kanamori K; Sano K
    Rinsho Byori; 1980 Mar; 28(3):235-8. PubMed ID: 7373885
    [No Abstract]   [Full Text] [Related]  

  • 19. Protein determination in cerebrospinal fluid by protein dye-binding assay.
    Marshall T; Williams KM
    Br J Biomed Sci; 2000; 57(4):281-6. PubMed ID: 11204856
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Assay of proteins in urine and cerebrospinal fluid by centrifugal analysis. Comparison of 3 methods].
    Massenet D; Molas J; Pressac D
    Ann Biol Clin (Paris); 1983; 41(2):151-4. PubMed ID: 6881627
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.