BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

157 related articles for article (PubMed ID: 33709957)

  • 1. Impact of a contrast-to-noise ratio driven and material specific exposure control on image quality and radiation exposure in angiography.
    Werncke T; Kemling M; Tashenov S; Hinrichs JB; Meine TC; Maschke SK; Kyriakou Y; Wacker FK; Meyer BC
    Phys Med Biol; 2021 Mar; 66(6):065020. PubMed ID: 33709957
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of a contrast-to-noise ratio-driven exposure control and a regular detector dose-driven exposure control in abdominal imaging in a clinical angiography system.
    Werncke T; Kemling M; Tashenov S; Hinrichs JB; Meine TC; Maschke SK; Kyriakou Y; Wacker FK; Meyer BC
    Med Phys; 2021 Dec; 48(12):7641-7656. PubMed ID: 34651705
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Tantalum-specific contrast-to-noise ratio or conventional detector dose-driven exposure control in angiography: radiation dose and image quality evaluation in a porcine model.
    Werncke T; Meine TC; Hinrichs JB; Maschke SK; Becker LS; Brüsch I; Rumpel R; Wacker FK; Meyer BC
    Eur Radiol Exp; 2022 May; 6(1):24. PubMed ID: 35578057
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Image Quality and Radiation Exposure in Abdominal Angiography: A Head-to-Head Comparison of Conventional Detector-Dose-Driven Versus Contrast-to-Noise Ratio-Driven Exposure Control at Various Source-to-Image Receptor Distances and Collimations in a Pilot Phantom and Animal Study.
    Werncke T; Becker LS; Maschke SK; Hinrichs JB; Meine TCH; Dewald CLA; Brüsch I; Rumpel R; Wacker FK; Meyer BC
    Invest Radiol; 2024 Mar; ():. PubMed ID: 38529924
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Pediatric thoracic CT angiography at 70 kV: a phantom study to investigate the effects on image quality and radiation dose.
    MacDougall RD; Kleinman PL; Yu L; Lee EY
    Pediatr Radiol; 2016 Jul; 46(8):1114-9. PubMed ID: 26987734
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of X-ray tube parameters, iodine concentration, and patient size on image quality in pulmonary computed tomography angiography: a chest-phantom-study.
    Szucs-Farkas Z; Verdun FR; von Allmen G; Mini RL; Vock P
    Invest Radiol; 2008 Jun; 43(6):374-81. PubMed ID: 18496042
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of x-ray tube parameters and iodine concentration on image quality and radiation dose in cerebral pediatric and adult CT angiography: a phantom study.
    Papadakis AE; Perisinakis K; Raissaki M; Damilakis J
    Invest Radiol; 2013 Apr; 48(4):192-9. PubMed ID: 23344518
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Characterization and potential applications of a dual-layer flat-panel detector.
    Shi L; Lu M; Bennett NR; Shapiro E; Zhang J; Colbeth R; Star-Lack J; Wang AS
    Med Phys; 2020 Aug; 47(8):3332-3343. PubMed ID: 32347561
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An examination of automatic exposure control regimes for two digital radiography systems.
    Marshall NW
    Phys Med Biol; 2009 Aug; 54(15):4645-70. PubMed ID: 19590115
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of radiation dose and image quality between flat panel computed tomography and multidetector computed tomography in a hybrid CT-angiography suite.
    Jones AK; Odisio BC
    J Appl Clin Med Phys; 2020 Feb; 21(2):121-127. PubMed ID: 31922349
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Using the K-edge to improve contrast conspicuity and to lower radiation dose with a 16-MDCT: a phantom and human study.
    Kalva SP; Sahani DV; Hahn PF; Saini S
    J Comput Assist Tomogr; 2006; 30(3):391-7. PubMed ID: 16778612
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Virtual monochromatic imaging in dual-source dual-energy CT: radiation dose and image quality.
    Yu L; Christner JA; Leng S; Wang J; Fletcher JG; McCollough CH
    Med Phys; 2011 Dec; 38(12):6371-9. PubMed ID: 22149820
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Increased radiation dose by automatic exposure control system during fluoroscopy and angiography of pelvis due to contrast material in the bladder: experimental study.
    Nakamura A; Ishiguchi T; Kamei S; Matsuda J; Ohno K; Murata K
    Radiat Med; 2004; 22(4):225-32. PubMed ID: 15468942
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Radiation dose and image quality in diagnostic radiology. Optimization of the dose-image quality relationship with clinical experience from scoliosis radiography, coronary intervention and a flat-panel digital detector.
    Geijer H
    Acta Radiol Suppl; 2002 Mar; 43(427):1-43. PubMed ID: 12108231
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Radiation dose and image quality of X-ray volume imaging systems: cone-beam computed tomography, digital subtraction angiography and digital fluoroscopy.
    Paul J; Jacobi V; Farhang M; Bazrafshan B; Vogl TJ; Mbalisike EC
    Eur Radiol; 2013 Jun; 23(6):1582-93. PubMed ID: 23250112
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Impact of the X-ray system setting on patient dose and image quality; a case study with two interventional cardiology systems.
    Vassileva J; Vano E; Ubeda C; Rehani M; Zotova R
    Radiat Prot Dosimetry; 2013 Jul; 155(3):329-34. PubMed ID: 23396881
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Evaluation of Radiation Dose and Image Quality for Angiographic System with Spectral Shaping Filter].
    Ichikawa N; Matsubara K; Fukuda A
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2019; 75(1):13-23. PubMed ID: 30662028
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Prospective Comparison of Reduced-Iodine-Dose Virtual Monochromatic Imaging Dataset From Dual-Energy CT Angiography With Standard-Iodine-Dose Single-Energy CT Angiography for Abdominal Aortic Aneurysm.
    Agrawal MD; Oliveira GR; Kalva SP; Pinho DF; Arellano RS; Sahani DV
    AJR Am J Roentgenol; 2016 Dec; 207(6):W125-W132. PubMed ID: 27610820
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Cerebral computed tomography angiography using a 70 kVp protocol: improved vascular enhancement with a reduced volume of contrast medium and radiation dose.
    Cho ES; Chung TS; Ahn SJ; Chong K; Baek JH; Suh SH
    Eur Radiol; 2015 May; 25(5):1421-30. PubMed ID: 25510446
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Filter material selection for region of interest radiologic imaging.
    Massoumzadeh P; Rudin S; Bednarek DR
    Med Phys; 1998 Feb; 25(2):161-71. PubMed ID: 9507475
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.