These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
169 related articles for article (PubMed ID: 33713872)
1. Combining load sensor and robotic technologies for ligament balance in total knee arthroplasty. Bardou-Jacquet J; Murgier J; Laudet F; Fabre T Orthop Traumatol Surg Res; 2022 Sep; 108(5):102889. PubMed ID: 33713872 [TBL] [Abstract][Full Text] [Related]
2. An anatomo-functional implant positioning technique with robotic assistance for primary TKA allows the restoration of the native knee alignment and a natural functional ligament pattern, with a faster recovery at 6 months compared to an adjusted mechanical technique. Parratte S; Van Overschelde P; Bandi M; Ozturk BY; Batailler C Knee Surg Sports Traumatol Arthrosc; 2023 Apr; 31(4):1334-1346. PubMed ID: 35552475 [TBL] [Abstract][Full Text] [Related]
4. How does the use of quantified gap-balancing affect component positioning and limb alignment in robotic total knee arthroplasty using functional alignment philosophy? A comparison of two robotic platforms. Murphy GT; Shatrov J; Duong J; Fritsch BA Int Orthop; 2023 May; 47(5):1221-1232. PubMed ID: 36740610 [TBL] [Abstract][Full Text] [Related]
5. Laxity Profiles in the Native and Replaced Knee-Application to Robotic-Assisted Gap-Balancing Total Knee Arthroplasty. Shalhoub S; Moschetti WE; Dabuzhsky L; Jevsevar DS; Keggi JM; Plaskos C J Arthroplasty; 2018 Sep; 33(9):3043-3048. PubMed ID: 29909956 [TBL] [Abstract][Full Text] [Related]
6. Ligament Tension and Balance before and after Robotic-Assisted Total Knee Arthroplasty - Dynamic Changes with Increasing Applied Force. Sharma AK; Plaskos C; Shalhoub S; Lawrence D; Vigdorchik JM; Lawrence JM J Knee Surg; 2024 Jan; 37(2):128-134. PubMed ID: 36731502 [TBL] [Abstract][Full Text] [Related]
7. Objective quantification of ligament balancing using VERASENSE in measured resection and modified gap balance total knee arthroplasty. Cho KJ; Seon JK; Jang WY; Park CG; Song EK BMC Musculoskelet Disord; 2018 Jul; 19(1):266. PubMed ID: 30053812 [TBL] [Abstract][Full Text] [Related]
8. Robotic-Assisted Total Knee Arthroplasty in the Presence of Extra-Articular Deformity. Sodhi N; Khlopas A; Ehiorobo JO; Condrey C; Marchand K; Marchand RC; Hepinstall MS; Mont MA Surg Technol Int; 2019 May; 34():497-502. PubMed ID: 30888672 [TBL] [Abstract][Full Text] [Related]
9. Comparison of Intraoperative Soft Tissue Balance Between Cruciate-Retaining and Posterior-Stabilized Total Knee Arthroplasty Performed by a Newly Developed Medial Preserving Gap Technique. Tsubosaka M; Muratsu H; Takayama K; Miya H; Kuroda R; Matsumoto T J Arthroplasty; 2018 Mar; 33(3):729-734. PubMed ID: 29103777 [TBL] [Abstract][Full Text] [Related]
10. Does the Robotic Arm and Preoperative CT Planning Help with 3D Intraoperative Total Knee Arthroplasty Planning? Marchand RC; Sodhi N; Bhowmik-Stoker M; Scholl L; Condrey C; Khlopas A; Sultan AA; Newman JM; Mont MA J Knee Surg; 2019 Aug; 32(8):742-749. PubMed ID: 30112739 [TBL] [Abstract][Full Text] [Related]
11. [Balancing technique using bone cuts]. Jeremić D; Haaker R Orthopade; 2020 Jul; 49(7):611-616. PubMed ID: 32430549 [TBL] [Abstract][Full Text] [Related]
12. One-stage total knee arthroplasty for patients with osteoarthritis of the knee and extra-articular deformity. Xiao-Gang Z; Shahzad K; Li C Int Orthop; 2012 Dec; 36(12):2457-63. PubMed ID: 23132502 [TBL] [Abstract][Full Text] [Related]
13. Functional alignment achieves soft-tissue balance in total knee arthroplasty as measured with quantitative sensor-guided technology. Chang JS; Kayani B; Wallace C; Haddad FS Bone Joint J; 2021 Mar; 103-B(3):507-514. PubMed ID: 33467917 [TBL] [Abstract][Full Text] [Related]
14. An intraoperative load sensor did not improve the early postoperative results of posterior-stabilized TKA for osteoarthritis with varus deformities. Song SJ; Kang SG; Lee YJ; Kim KI; Park CH Knee Surg Sports Traumatol Arthrosc; 2019 May; 27(5):1671-1679. PubMed ID: 30511096 [TBL] [Abstract][Full Text] [Related]
15. The Effect of Minor Adjustments to Tibial and Femoral Component Position on Soft Tissue Balance in Robotic Total Knee Arthroplasty. Young SW; Clark GW; Esposito CI; Carter M; Walker ML J Arthroplasty; 2023 Jun; 38(6S):S238-S245. PubMed ID: 36933677 [TBL] [Abstract][Full Text] [Related]
16. The influence of tibiofemoral joint forces on patient-reported outcome measurements after bicruciate stabilized total knee arthroplasty. Kaneko T; Kono N; Mochizuki Y; Hada M; Toyoda S; Ikegami H; Musha Y J Orthop Surg (Hong Kong); 2020; 28(2):2309499020915106. PubMed ID: 32308123 [TBL] [Abstract][Full Text] [Related]
17. The Influence of Joint Distraction Force on the Soft-Tissue Balance Using Modified Gap-Balancing Technique in Posterior-Stabilized Total Knee Arthroplasty. Nagai K; Muratsu H; Takeoka Y; Tsubosaka M; Kuroda R; Matsumoto T J Arthroplasty; 2017 Oct; 32(10):2995-2999. PubMed ID: 28550965 [TBL] [Abstract][Full Text] [Related]
18. Virtual assessment of coronal balance prior to bone resection with the MAKO robotic-assisted system accurately predicts final balance in TKA. Manara JR; Goonatillake M; Marley M; Pretty W; Collopy D; Clark G J Robot Surg; 2023 Dec; 17(6):2849-2854. PubMed ID: 37776492 [TBL] [Abstract][Full Text] [Related]