BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

176 related articles for article (PubMed ID: 33725907)

  • 1. Randomized controlled trial comparing a conventional needle and a novel needle for endoscopic ultrasound (EUS)-guided histology of peripancreatic masses.
    Lee HW; Kim KM
    Medicine (Baltimore); 2021 Mar; 100(10):e25106. PubMed ID: 33725907
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Endoscopic ultrasound-guided sampling of solid pancreatic masses: 22-gauge aspiration versus 25-gauge biopsy needles.
    Yang MJ; Yim H; Hwang JC; Lee D; Kim YB; Lim SG; Kim SS; Kang JK; Yoo BM; Kim JH
    BMC Gastroenterol; 2015 Sep; 15():122. PubMed ID: 26419845
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of 22-gauge standard fine needle versus core biopsy needle for endoscopic ultrasound-guided sampling of suspected pancreatic cancer: a randomized crossover trial.
    Noh DH; Choi K; Gu S; Cho J; Jang KT; Woo YS; Lee KT; Lee JK; Lee KH
    Scand J Gastroenterol; 2018 Jan; 53(1):94-99. PubMed ID: 29065734
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Touch imprint cytology on endoscopic ultrasound fine-needle biopsy provides comparable sample quality and diagnostic yield to standard endoscopic ultrasound fine-needle aspiration specimens in the evaluation of solid pancreatic lesions.
    Crinò SF; Larghi A; Bernardoni L; Parisi A; Frulloni L; Gabbrielli A; Parcesepe P; Scarpa A; Manfrin E
    Cytopathology; 2019 Mar; 30(2):179-186. PubMed ID: 30484917
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Core biopsy needle versus standard aspiration needle for endoscopic ultrasound-guided sampling of solid pancreatic masses: a randomized parallel-group study.
    Lee YN; Moon JH; Kim HK; Choi HJ; Choi MH; Kim DC; Lee TH; Cha SW; Cho YD; Park SH
    Endoscopy; 2014 Dec; 46(12):1056-62. PubMed ID: 25098611
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of 22G standard and Franseen needles in endoscopic ultrasound-guided fine-needle aspiration for diagnosing pancreatic mass lesions: Study protocol for a controlled trial.
    Itonaga M; Yasukawa S; Shimokawa T; Takenaka M; Fukutake N; Ogura T; Sakagami J; Shiomi H; Okura Y; Inatomi O; Matsumoto H; Kurita A; Suzuki A; Tanaka K; Kitano M
    Trials; 2019 Dec; 20(1):816. PubMed ID: 31888733
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A Comparative Study of the Diagnostic Utility of Endoscopic Ultrasound-Guided Fine Needle Aspiration Cytology (EUS-FNA) versus Endoscopic Ultrasound-Guided Fine Needle Biopsy (EUS-FNB) in Pancreatic and Non-Pancreatic Lesions.
    Yousri M; Abusinna E; Tahoun N; Okasha HH; El-Habashi AH
    Asian Pac J Cancer Prev; 2022 Jun; 23(6):2151-2158. PubMed ID: 35763660
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Randomized trial comparing the 22-gauge aspiration and 22-gauge biopsy needles for EUS-guided sampling of solid pancreatic mass lesions.
    Bang JY; Hebert-Magee S; Trevino J; Ramesh J; Varadarajulu S
    Gastrointest Endosc; 2012 Aug; 76(2):321-7. PubMed ID: 22658389
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of a stylet on a histological specimen in EUS-guided fine-needle tissue acquisition by using 22-gauge needles: a multicenter, prospective, randomized, controlled trial.
    Abe Y; Kawakami H; Oba K; Hayashi T; Yasuda I; Mukai T; Isayama H; Ishiwatari H; Doi S; Nakashima M; Yamamoto N; Kuwatani M; Mitsuhashi T; Hasegawa T; Hirose Y; Yamada T; Tanaka M; Sakamoto N;
    Gastrointest Endosc; 2015 Nov; 82(5):837-844.e1. PubMed ID: 25936452
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Feasibility and yield of a novel 22-gauge histology EUS needle in patients with pancreatic masses: a multicenter prospective cohort study.
    Larghi A; Iglesias-Garcia J; Poley JW; Monges G; Petrone MC; Rindi G; Abdulkader I; Arcidiacono PG; Costamagna G; Biermann K; Bories E; Doglioni C; Dominguez-Muñoz JE; Hassan C; Bruno M; Giovannini M
    Surg Endosc; 2013 Oct; 27(10):3733-8. PubMed ID: 23644834
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparative accuracy of needle sizes and designs for EUS tissue sampling of solid pancreatic masses: a network meta-analysis.
    Facciorusso A; Wani S; Triantafyllou K; Tziatzios G; Cannizzaro R; Muscatiello N; Singh S
    Gastrointest Endosc; 2019 Dec; 90(6):893-903.e7. PubMed ID: 31310744
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Analysis of Fine-Needle Biopsy vs Fine-Needle Aspiration in Diagnosis of Pancreatic and Abdominal Masses: A Prospective, Multicenter, Randomized Controlled Trial.
    Cheng B; Zhang Y; Chen Q; Sun B; Deng Z; Shan H; Dou L; Wang J; Li Y; Yang X; Jiang T; Xu G; Wang G
    Clin Gastroenterol Hepatol; 2018 Aug; 16(8):1314-1321. PubMed ID: 28733257
    [TBL] [Abstract][Full Text] [Related]  

  • 13. EUS-guided fine needle biopsy sampling using a novel fork-tip needle: a case-control study.
    Kandel P; Tranesh G; Nassar A; Bingham R; Raimondo M; Woodward TA; Gomez V; Wallace MB
    Gastrointest Endosc; 2016 Dec; 84(6):1034-1039. PubMed ID: 27018087
    [TBL] [Abstract][Full Text] [Related]  

  • 14. 22-Gauge biopsy needles have a better histological diagnostic yield in the discrimination of specific pancreatic solid neoplasms.
    Jiang H; Guo J; Wang K; Zhu H; Chen J; Xu C; Wang D; Jin Z
    Scand J Gastroenterol; 2019 Jan; 54(1):101-107. PubMed ID: 30731044
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of 22G fine-needle aspiration (FNA) versus fine-needle biopsy (FNB) for endoscopic ultrasound-guided sampling of pancreatic lesions: a prospective comparison study.
    Tian L; Tang AL; Zhang L; Liu XW; Li JB; Wang F; Shen SR; Wang XY
    Surg Endosc; 2018 Aug; 32(8):3533-3539. PubMed ID: 29404729
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of the Diagnostic Performance of Newly Designed 21-Gauge and Standard 22-Gauge Aspiration Needles in Patients with Solid Pancreatic Masses.
    Minaga K; Yoshikawa T; Yamashita Y; Akamatsu H; Ikenouchi M; Ishii T; Matsumoto H; Iwagami H; Nakatani Y; Hatamaru K; Takenaka M; Akamatsu T; Uenoyama Y; Watanabe T; Ono K; Chiba Y; Kudo M
    Dig Dis Sci; 2019 Oct; 64(10):2982-2991. PubMed ID: 31011943
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of the diagnostic performance of 2 core biopsy needles for EUS-guided tissue acquisition from solid pancreatic lesions.
    Nayar MK; Paranandi B; Dawwas MF; Leeds JS; Darne A; Haugk B; Majumdar D; Ahmed MM; Oppong KW
    Gastrointest Endosc; 2017 May; 85(5):1017-1024. PubMed ID: 27633157
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of endoscopic ultrasound-guided fine-needle biopsy versus fine-needle aspiration for genomic profiling and DNA yield in pancreatic cancer: a randomized crossover trial.
    Kandel P; Nassar A; Gomez V; Raimondo M; Woodward TA; Crook JE; Fares NS; Wallace MB
    Endoscopy; 2021 Apr; 53(4):376-382. PubMed ID: 32767288
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A Meta-Analysis Comparing Endoscopic Ultrasound-guided Fine-needle Aspiration With Endoscopic Ultrasound-guided Fine-needle Biopsy.
    Li Z; Liu W; Xu X; Li P
    J Clin Gastroenterol; 2022 Sep; 56(8):668-678. PubMed ID: 35470294
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Technical aspects of endoscopic ultrasound (EUS)-guided sampling in gastroenterology: European Society of Gastrointestinal Endoscopy (ESGE) Technical Guideline - March 2017.
    Polkowski M; Jenssen C; Kaye P; Carrara S; Deprez P; Gines A; Fernández-Esparrach G; Eisendrath P; Aithal GP; Arcidiacono P; Barthet M; Bastos P; Fornelli A; Napoleon B; Iglesias-Garcia J; Seicean A; Larghi A; Hassan C; van Hooft JE; Dumonceau JM
    Endoscopy; 2017 Oct; 49(10):989-1006. PubMed ID: 28898917
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.