BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

123 related articles for article (PubMed ID: 33730909)

  • 1. Multi-scale semi-analytical model for fatigue life prediction of trans-tibial prosthetic sockets.
    Mankai W; Ben Smida B; Chafra M; Ben Cheikh R
    Proc Inst Mech Eng H; 2021 Jun; 235(6):688-700. PubMed ID: 33730909
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Influence of the scale reduction in designing sockets for trans-tibial amputees.
    Dakhil N; Tarrade T; Behr M; Mo F; Evin M; Thefenne L; Liu T; Llari M
    Proc Inst Mech Eng H; 2020 Aug; 234(8):761-768. PubMed ID: 32475295
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effects of long-distance walking on socket-limb interface pressure, tactile sensitivity and subjective perceptions of trans-tibial amputees.
    Yeung LF; Leung AK; Zhang M; Lee WC
    Disabil Rehabil; 2013 Jun; 35(11):888-93. PubMed ID: 22992201
    [TBL] [Abstract][Full Text] [Related]  

  • 4. CAD/CAM evaluation of the fit of trans-tibial sockets for trans-tibial amputation stumps.
    Isozaki K; Hosoda M; Masuda T; Morita S
    J Med Dent Sci; 2006 Mar; 53(1):51-6. PubMed ID: 16722145
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Does actively enlarging socket volume during resting facilitate residual limb fluid volume recovery in trans-tibial prosthesis users?
    Larsen BG; McLean JB; Brzostowski JT; Carter R; Allyn KJ; Hafner BJ; Garbini JL; Sanders JE
    Clin Biomech (Bristol, Avon); 2020 Aug; 78():105001. PubMed ID: 32619870
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Design of lower limb prosthetic sockets: a review.
    Wang M; Nong Q; Liu Y; Yu H
    Expert Rev Med Devices; 2022 Jan; 19(1):63-73. PubMed ID: 34932435
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Interface Pressure System to Compare the Functional Performance of Prosthetic Sockets during the Gait in People with Trans-Tibial Amputation.
    Ibarra Aguila S; Sánchez GJ; Sauvain EE; Alemon B; Fuentes-Aguilar RQ; Huegel JC
    Sensors (Basel); 2020 Dec; 20(24):. PubMed ID: 33317006
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Techniques for Interface Stress Measurements within Prosthetic Sockets of Transtibial Amputees: A Review of the Past 50 Years of Research.
    Al-Fakih EA; Abu Osman NA; Mahmad Adikan FR
    Sensors (Basel); 2016 Jul; 16(7):. PubMed ID: 27447646
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A comparison of trans-tibial amputee suction and vacuum socket conditions.
    Board WJ; Street GM; Caspers C
    Prosthet Orthot Int; 2001 Dec; 25(3):202-9. PubMed ID: 11860094
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Assessment of Socket Pressure during Walking in Rapid Fit Prosthetic Sockets.
    Sasaki K; Guerra G; Lei Phyu W; Chaisumritchoke S; Sutdet P; Kaewtip S
    Sensors (Basel); 2022 Jul; 22(14):. PubMed ID: 35890905
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An Inductive Sensing System to Measure In-Socket Residual Limb Displacements for People Using Lower-Limb Prostheses.
    Henrikson KM; Weathersby EJ; Larsen BG; Cagle JC; McLean JB; Sanders JE
    Sensors (Basel); 2018 Nov; 18(11):. PubMed ID: 30423932
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Sustainable, affordable and functional: reimagining prosthetic liners in resource limited environments.
    Miyata Y; Sasaki K; Guerra G; Rattanakoch J
    Disabil Rehabil; 2022 Jun; 44(12):2941-2947. PubMed ID: 33167733
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Engineering a trans-tibial prosthetic socket for the lower limb amputee.
    Laing S; Lee PV; Goh JCh
    Ann Acad Med Singap; 2011 May; 40(5):252-9. PubMed ID: 21678017
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Walking in a vacuum-assisted socket shifts the stump fluid balance.
    Goswami J; Lynn R; Street G; Harlander M
    Prosthet Orthot Int; 2003 Aug; 27(2):107-13. PubMed ID: 14571940
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Functional effects of a prosthetic torsion adapter in trans-tibial amputees during unplanned spin and step turns.
    Heitzmann DW; Pieschel K; Alimusaj M; Block J; Putz C; Wolf SI
    Prosthet Orthot Int; 2016 Oct; 40(5):558-65. PubMed ID: 26195621
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Socket Interface Pressure and Amputee Reported Outcomes for Comfortable and Uncomfortable Conditions of Patellar Tendon Bearing Socket: A Pilot Study.
    Safari MR; Tafti N; Aminian G
    Assist Technol; 2015; 27(1):24-31; quiz 32-3. PubMed ID: 26132222
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Literature review of the possible advantages of silicon liner socket use in trans-tibial prostheses.
    Baars EC; Geertzen JH
    Prosthet Orthot Int; 2005 Apr; 29(1):27-37. PubMed ID: 16180375
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Adjustable sockets may improve residual limb fluid volume retention in transtibial prosthesis users.
    Brzostowski JT; Larsen BG; Youngblood RT; Ciol MA; Hafner BJ; Gurrey CJ; McLean JB; Allyn KJ; Sanders JE
    Prosthet Orthot Int; 2019 Jun; 43(3):250-256. PubMed ID: 30628522
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Modeling and simulation of muscle forces of trans-tibial amputee to study effect of prosthetic alignment.
    Fang L; Jia X; Wang R
    Clin Biomech (Bristol, Avon); 2007 Dec; 22(10):1125-31. PubMed ID: 17942203
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of the new, patient-adjustable socket system Varos in the early phase of prosthetic rehabilitation: a pilot study.
    Nia A; Toetschinger G; Kubinec T; Domayer S
    Eur J Phys Rehabil Med; 2022 Jun; 58(3):462-469. PubMed ID: 35148042
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.